Shea Couture 1) Which of the following is not a peripheral cause of a loss of airway patency?

a) b) c) d) Infection Traumatic Brain Injury (TBI) (Module 1 Obj. 2, slide 7) Allergic reaction Foreign body aspiration

2) What part is unique to the Liver Pool flow-inflating resuscitator that is not on the Jackson Reese? a) b) c) d) 15/22mm connector Oxygen inlet Flow control Valve (Module 2 Obj. 3 slide 9) Thin-walled anaesthesia bag

3) EMS brings in a large adult male into the ER and are having trouble bag mask ventilating him. They ask you to grab a LMA classic for them to use. What size do you choose? a) b) c) d) 3 4 5 6

(Module 3 All Obj. Slide 18)

4) While assessing a patient with a Mallampati score of Class II, you would expect to see the following and with what difficulty of intubation: a) b) c) d) Soft palate, uvula, fauces no difficulty (Module 4 Obj. 2, slide 13) Soft palate, uvula, fauces moderately difficult Soft palate, base of uvula moderately difficult Soft palate, base of uvula severe difficulty

5) Ventilation and oxygenation can be assessed by assessing: a) Mentation b) Degree of fatigue c) Cyanosis

d) B and C e) All of the above

(Module 5 Obj. 1, slide 8)

6) Which laryngoscopy technique is incorrect? a) Inserting the tip of the Miller blade into the vallecula and lifting up the epiglottis (Module 6 obj. 1, slide 25) b) Inserting the tip of the MacIntosh blade into the vallecula and lifting up the epiglottis c) Inserting the tip of the Miller blade over the posterior surface of the epiglottis and lifting it up d) Using the laryngoscope blade to lift up and away, not levering against the teeth 7) You must intubate a 2400g baby in the NICU. What size of ETT will you use and what size catheter would be used to suction? a) 3.0 ETT, 5/6F b) 3.0 ETT, 8F c) 3.5 ETT, 8F (Module 7 Obj. 1, Slide 6+7) d) 3.5 ETT, 10F 8) This ETT tubes disadvantage is that when it is kinked, it does not easily regain its original shape. a) b) c) d) Anode tube (Module 8 Obj. 2, slide 17) Rae tube DLET tube Endotrol tube

9) Which is not an indication for extubation? a) b) c) d) No immediate need for mechanical ventilation Minimal risk for obstruction Patient-ventilator dissynchrony (Module 9 Obj.2, slide 17 FIO2 requirements able to be met via NP

10) After the surgical cricothyrotomy procedure was finished the surgeon placed a LPC Shiley tracheostomy tube. If the inner cannula of this trach were to be removed, would you still be able to properly attach the bagging unit to the trach? a) Yes, the 15mm connector is on the outer cannula

b) No, the 15mm connector is on the inner cannula (Module 11 Obj.1 slide 21) c) No, Shiley trachs do not have a 15mm connector d) No, I dont know how to use a bagging unit