Functional Overview

Functional Overview
Streamlined system implementation
> Initial setup on the Base Station of Base-Station-specific, system-wide, and select Subscriber Station parameters > Minimal configuration on individual Subscriber Stations themselves

Initialization/Setup process
> System Setup > SS Initialization, Authentication, Registration > Wireless Communication/Service Classes > System Monitoring

Intended for internal Proxim use only

Functional Overview: System Setup


Configure local BS and system-wide options through HTTP, CLI, or SNMP
> System
> MAC > Radio > Networking

> SS Authentication
> SS List > Service Class Creation > Logging

Intended for internal Proxim use only

Functional Overview: SS Initialization, Authentication, and Registration


Initial SS Synchronization with the BS
> Timing, Frequency, Power

Registration
Operational setting negotiation
> Capabilities, Service Flow initiation

Local SS configuration
> SS system info > Radio > Networking

> Log

Intended for internal Proxim use only

Functional Overview: Wireless Communication and Service Classes


Uplink/Downlink traffic
> Uplink: SS to BS

> Downlink: BS to SS
> TDD operation

Subscriber Station Classes


> PIRs/Service Flows > Pre-defined and custom class availability

Intended for internal Proxim use only

Functional Overview: System Monitoring


Interface statistics MAC statistics Service Flow statistics SS Statistics (BS only) Log messages

Intended for internal Proxim use only

Hardware Overview

Hardware Overview: BS/SS Radios


Frequency channels Signal radiation/reception Up-conversion/down-conversion Modulation/demodulation Wireless MAC functions
SS/BS with External Antenna Connector

Network services
BS management

SS with Integrated Antenna

Intended for internal Proxim use only

Hardware Overview: LEDs


Ethernet and RF LEDs on PWR/ENET port

LED behavior

Intended for internal Proxim use only

Hardware Overview: Power Injector


PoE over 24 AWG CAT5 cable Proprietary PoE: non 802.3af-compatible Power LED

Intended for internal Proxim use only

Hardware Overview: Antenna Options Omni-Directional

Intended for internal Proxim use only

Hardware Overview: Antenna Options Panel Antennas


Model 3338-A00-060
>60 degree >17 dBi gain

Model 3338-A00-090
> 90 degree > 14 dBi gain

Model 3338-A00-120
> 120 degree > 13 dBi gain

Model 3437-A00-018
>18 degree >18 dBi gain
Intended for internal Proxim use only

Hardware Overview: Antennas


Integrated vs. External External antenna connector specifications:

Antenna Installation Guide and Recommended Antennas Guide provide more information

Intended for internal Proxim use only

Hardware Overview: Serial Connection


RJ45 to DB9 CLI commands Future releases:
> Audible Antenna Pointing

Intended for internal Proxim use only

Hardware Overview: Product Package


BS/SS Radio Serial dongle (BS only) Power injector/cord Cable termination kit Mounting kit and hardware

Installation CD
> MIBs > Documentation > Online Help

> TFTP Server


> Adobe Acrobat

Intended for internal Proxim use only

Hardware Installation

Hardware Installation
Professional installation required Pole- or wall-mountable Lightning arrestor recommended

Intended for internal Proxim use only

Hardware Installation: Step 1


Choose a location
> > > > The location must allow easy disconnection of power to the radio if necessary. Air must be able to flow freely around the hardware. The radio unit must be kept away from vibration and excessive heat. The installation must conform to local regulations at all times.

Intended for internal Proxim use only

Hardware Installation: Step 2


Pre-Assemble Hardware
> Note serial numbers and Ethernet/MAC address > Cable termination: A: Sealing Nut B: Lock Nut C: RJ45 Sealing Cap D: RJ45 Connector

Intended for internal Proxim use only

Hardware Installation: Step 2 (continued)


Pre-Assemble Hardware (continued)
> Determine mounting orientation

> Attach mounting plate, extension arm, and mounting bracket


Mounting bracket Extension arm Mounting plate

Intended for internal Proxim use only

Hardware Installation: Step 3


Connect the Cables
> Connect to Power Injector

> Connect to BS/SS

> Connect to hub/switch/stand-alone PC

Intended for internal Proxim use only

Hardware Installation: Steps 4-5


Power-on the unit View LEDs
> LED behavior:

Intended for internal Proxim use only

Hardware Installation: Step 6


Mount the unit
> Pole mount

> Wall mount

Intended for internal Proxim use only

Hardware Installation: Steps 7-8


Align the Antenna
> Link Budget calculation (calculator provided in KBK 1846)

> Compare to SNR on SS From SS: Monitor > Statistics > MAC Statistics
> Physically adjust the antenna

Complete Installation
> Tighten sealing caps with proper torque

Intended for internal Proxim use only

Initial Configuration

Initial Configuration: Logging In


Default IP address:
> BS: 192.168.10.1

> SS: 192.168.10.2

Default login credentials


> Administrator: Enter admin in the User Name field. For new units, the default administrator password is public.

> User: Enter user in the User Name field. For new units, the default password is public.

Intended for internal Proxim use only

Initial Configuration: The Web Interface


Menu section Configuration parameters section

Intended for internal Proxim use only

Initial Configuration: Latest Software


Download latest software from Proxim Web site Install using TFTP via Web (shown) or CLI

Intended for internal Proxim use only

Initial Configuration: Mandatory Parameters


Mandatory for communication
> Center Frequency on BS and SS (BS shown below)

> Configuration > Radio

Intended for internal Proxim use only

Initial Configuration: Mandatory Parameters (continued)


Mandatory for security
> IP Address (SS/BS) (BS shown) BS: Configuration > Networking > Basic

SS: Configuration > Networking

Intended for internal Proxim use only

Initial Configuration: Mandatory Parameters (continued)


Mandatory for security (continued)
> Passwords (BS) Commands > Passwords

Intended for internal Proxim use only

Initial Configuration: Mandatory Parameters (continued)


Mandatory for security (continued)
> Net Entry Mode (BS) Configure > SS Authentication Unrestricted: all SSs may enter network (not secure) Internal Authorization: only SSs listed in the BSs list of authorized SSs may enter network

Intended for internal Proxim use only

BS Configuration

Base Station Configuration Categories


System MAC
> Basic > Advanced

SS Authentication SS List Service Class Creation


> PIRs > SF Class > SS Class

Radio Downlink Burst Profile Uplink Burst Profile Networking


> VLANs VLAN ID List > Bridging > Static Routes

Logging

Intended for internal Proxim use only

BS Configuration: System Parameters


Configuration > System
> BS-specific identification, location, and contact information

Intended for internal Proxim use only

BS Configuration: MAC Parameters (Basic)


Configuration > MAC > Basic
> Tune 802.16 MAC implementation based on network environment

Downlink Percentage Recommendations

Intended for internal Proxim use only

BS Configuration: MAC Parameters (Advanced)


Configuration > MAC > Advanced
> Should be modified only by experienced users

Intended for internal Proxim use only

BS Configuration: Radio Parameters


Configuration > Radio
> Control channel bandwidth, frequency, transmit power, broadcast rate

Intended for internal Proxim use only

BS Configuration: DL Burst Profile


Configuration > Downlink Burst Profile
> Enable or disable downlink modulation rates

Intended for internal Proxim use only

BS Configuration: UL Burst Profile


Configuration > Uplink Burst Profile
> Enable or disable uplink modulation rates

Disabled by default

Intended for internal Proxim use only

BS Configuration: Networking (Basic)


Configuration > Networking > Basic
> Set the parameters of the BSs Ethernet interface

Intended for internal Proxim use only

BS Configuration: Networking (VLANs)


BS VLAN modes
> Transparent

> Trunk

SS VLAN modes depend on VLAN mode of BS


> Transparent: Available when BS is in Transparent > Trunk: Available when BS is in Trunk > Access: Available when BS is in either Transparent or Trunk

Intended for internal Proxim use only

BS Configuration: Networking (VLANs) (continued)


BS in Transparent Mode
> SS in Transparent or Access Modes

Intended for internal Proxim use only

BS Configuration: Networking (VLANs) (continued)


BS in Trunk Mode
> SS in Transparent or Access Modes

Intended for internal Proxim use only

BS Configuration: Networking (VLANs) (continued)


VLAN ID List
> Configuration > Networking > VLANs > VLAN ID List > Add VLAN IDs to be used in the system

Intended for internal Proxim use only

BS Configuration: Networking (Bridging)


Configuration > Networking > VLANs > Bridging
> Set the VLAN mode and associated bridging parameters for the BS

> With mode set to Transparent (below), no further action is needed

Intended for internal Proxim use only

BS Configuration: Networking (Bridging) (continued)


Additional VLAN information will be provided after the product is generally available

Intended for internal Proxim use only

BS Configuration: Networking (Static Routes)


Configuration > Networking > Static Routes
> Add/Edit up to 16 fixed routes from the BSs Ethernet address to other points on the network

Intended for internal Proxim use only

BS Configuration: SS Authentication
Configuration > SS Authentication
> Net Entry Mode Unrestricted access (not secure) Internal Authorization > Default SS Class

Intended for internal Proxim use only

BS Configuration: SS List
Configuration > SS List
> Add SSs to the network, associate them with a non-default SS Class, configure select SS-specific parameters

> SS List Population: Net Entry mode Unrestricted: SSs added automatically Net Entry mode Internal Authorization: SSs added manually Initially: Default SS Class assigned
Intended for internal Proxim use only

BS Configuration: SS List (continued)


Optional SS Configuration
> Assign non-default SS Class to individual SSs > Override select SS Class parameters on a per-SS basis

Intended for internal Proxim use only

BS Configuration: Service Classes


Each SS must be associated with an SS Class (service class) Pre-defined classes supplied with unit Custom classes may be created

Intended for internal Proxim use only

BS Configuration: Service Classes (continued)


SS Class building blocks
> Packet Identification Rules (PIRs)

> Service Flows


> Networking parameters

Intended for internal Proxim use only

BS Configuration: Service Classes (continued)


Packet Identification Rules
> Matched against fields of incoming packets to map to appropriate Service Flow > One or more of 11 different classifier fields If multiple classifiers used, every included classifier must match incoming packet for rule to patch > Examples: ToS field to identify a certain class of differentiated IP traffic IP address field to identify uplink traffic destined to a particular server address (IE: VoIP gateway)

Intended for internal Proxim use only

BS Configuration: Service Classes (continued)


Service Flows
> Determine traffics QoS treatment

> Comprised of two elements: Direction QoS traffic scheduling mechanisms

Intended for internal Proxim use only

BS Configuration: Service Classes (continued)


Networking parameters
> VLAN settings

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Process Overview
> Create PIRs

> Create Service Flows


> Create SS Class Step 1: Select Service Flows Step 2: Associate PIRs with Service Flows Step 3: Set networking parameters

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit PIRs
> Configuration > Service Class Creation > PIR

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit PIRs (continued)
> Select Classifiers

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Pre-Defined PIRs

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit Service Flows
> Configuration > Service Class Creation > SF Class

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit SFs (continued)
> Set Parameters

Note: For real time applications like voice and video, select UGS; For all other applications, Best Effort is recommended
Intended for internal Proxim use only

BS Configuration: Service Class Creation


Pre-Defined SF classes

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit SS Classes
> Configuration > Service Class Creation > SS Class

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit SS Classes (continued)
> Step 1: Select Service Flows

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit SS Classes (continued)
> Step 2: Associate PIRs with SFs

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Create/Edit SS Classes (continued)
> Step 3: Set Networking Parameters: VLAN Mode = Transparent

Intended for internal Proxim use only

BS Configuration: Service Class Creation


Pre-Defined SS Classes
> All use Transparent VLAN mode

Intended for internal Proxim use only

BS Configuration: Logging
Configuration > Logging
> Set the parameters for the logging functions of the BS

Intended for internal Proxim use only

Subscriber Station Configuration

Subscriber Station Configuration Categories


System Radio Networking Logging

Intended for internal Proxim use only

SS Configuration: System
Configuration > System
> Local SS-specific information

Intended for internal Proxim use only

SS Configuration: Radio
Configuration > Radio
> Control channel bandwidth and frequency, and specify a BS connection

Intended for internal Proxim use only

SS Configuration: Network
Configuration > Network
> Set the Ethernet IP address and mask, and specify the default gateway

Intended for internal Proxim use only

SS Configuration: Logging
Configuration > Logging
> Set the parameters for the logging functions of the SS

Intended for internal Proxim use only

BS/SS Commands

Commands: Update to BS/SS


Commands > Update to BS/SS > via TFTP
> Update software images and configuration files to the unit

Intended for internal Proxim use only

Commands: Reboot
Commands > Reboot
> Save configuration changes (if any) and reboot the unit.

Intended for internal Proxim use only

Commands: Reset BS/SS


Commands > Reset BS/SS
> Reset to factory default conditions.

Intended for internal Proxim use only

Commands: Passwords
Commands > Reset BS/SS
> Change passwords

Intended for internal Proxim use only

BS/SS Log Messages

BS/SS Log Messages


Logs > Flash Logs > RAM

Intended for internal Proxim use only

BS/SS Log Messages (continued)

Intended for internal Proxim use only

BS Monitoring

BS Monitoring: Ethernet Statistics


Monitor > Ethernet Statistics

Intended for internal Proxim use only

BS Monitoring: MAC Statistics


Monitor > MAC Statistics

Intended for internal Proxim use only

BS Monitoring: SF Statistics
Monitor > SF Statistics List

Intended for internal Proxim use only

BS Monitoring: Registered SSs


Monitor > SS

Intended for internal Proxim use only

SS Monitoring

SS Monitoring: Ethernet Statistics


Monitor > Ethernet Statistics

Intended for internal Proxim use only

SS Monitoring: MAC Statistics


Monitor > MAC Statistics

Intended for internal Proxim use only

SS Monitoring: SF Statistics
Monitor > SF Statistics

Intended for internal Proxim use only