Beruflich Dokumente
Kultur Dokumente
" ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 12" OAL OILMISER 3 Piece Sampling Tubes - 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL " ID (Large Bore) SSt pitot tube, 1/4" NPT (in line) sampling valve port, 24" OAL Use with OST (in line) Oil Sampling Tube for 90 position & 360 rotation Includes Pitot Tube, Mounting Bolts, O'ring, & SV-MB25 Sampling Valve Includes Pitot Tube, Mounting Bolts, O'ring, & SV-MB25 Sampling Valve Includes Pitot Tube, Mounting Bolts, O'ring, & SV-MB25 Sampling Valve Includes Pitot Tube, Mounting Bolts, O'ring, & SV-MB25 Sampling Valve Includes Pitot Tube, Mounting Bolts, O'ring, & SV-MB25 Sampling Valve OILMISER Oil Sampling Valves & Accessories Sampling Valve & Tethered Cap. Use with Sampling Probe & Vacuum pump Sampling Probe for SV-MB25 above. Use with " OD x .170 ID plastic tube Sampling Valve & Tethered Cap. Use with Sampling Probe & Vacuum pump Sampling Probe for SV-HF25 above. Use with " OD x .170 ID plastic tube Use with OST Oil Sampling Tubes for removal or positioning Pitot Tube Hand held Vacuum Pump. Use with SV / SP-MB25 or SV / SP-HF25 OILMISER 6100 Series SAE 4 Bolt Sandwich Plate Kit for On Line Oil Sampling
SPK-6120-12-STMB25 SPK-6120-16-STMB25 SPK-6120-20-STMB25 SPK-6120-24-STMB25 SPK-6120-32-STMB25 SV-MB25 SP-MB25 SV-HF25 SP-HF25 TOT-02505 VAC-38P SV-PT025 SV-PT038 SV-PT050 SV-PT075 PTP-2510 PTP-2515 PTP-2520 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each 1 Each
NEW
Sampling Valve Sampling Valve Sampling Valve Sampling Valve Pitot Tube Pitot Tube Pitot Tube " NPT Male " NPT Male " NPT Male " NPT Male " OD x 10" " OD x 15" " OD x 20"
Customer Name:__________________________
Date:______________________
Technology
The Oil Sample. Where Oil Analysis Begins
www.oilmiser.com
Most of gearbox manufacturers recognize the value of clean oil and specify oil cleanliness levels in their warranty. Few however pre-install the fittings and attachments needed for drawing reliable oil samples. To ensure safe and consistent oil sampling procedures, its the job of the end user or the after market service provider to install these fittings and attachments in the field. Industry Leading OILMISER Technology The features that sets the OILMISER Sampling Tube apart from the conventional oil sampling tube is our exclusive 3 piece design. This gives the installer unparalleled flexibility to chose the best location for the safety and convenience of the service technician. A job that is easier to do, is a job that gets done well and on schedule. 1. The gland bushing is designed to fit directly into a pipe port on the gearbox ranging from " NPT to 2" NPT, or into an SAE Oring port from Dash-6 to Dash-24. 2. The removable stainless steel pitot tube, has a full " I.D. and is suitable for the heaviest gear oils. 3. The pitot tube retaining gland has a " NPT female pipe port for a Lo-Viscosity sampling valve used with lighter lubricating oils, or a Hi-Viscosity sampling valve used with heavier gear oils. Installing the OILMISER Sampling Tube The wide range of OILMISER gland bushing sizes means that a sampling valve can be installed directly into a pipe port without using additional pipe reducer bushings often required with conventional pitot tubes. In addition to reducing the installation time, it also eliminates potential oil leaks. Metal to metal contact between the gland bushing and the sealed tube retainer gland means that the final position of the sampling valve can be predetermined prior to installation. This is an important feature, when considering the safety and convenience of the service technician who draws the oil sample. The optional 90 degree by 360 swivel adds even greater flexibility to the final orientation of the sampling valve whenever accessibility is the concern.
JLM Systems Limited 23091 Westminster Highway Richmond, BC Canada V6V 1B9
Toll Free: 1-888-RENU OIL(736-8645) Phone: 604-521-3248 Fax: 604-521-1244 E-mail: info@oilmiser.com
Technology
The more Standardized your Procedures
www.oilmiser.com
Whether you're sampling hydraulic oil using a Minimess Series B sampling valve and a Vacuum Pump, or sampling VG-460 gear oil using a Hi-Flow / Hi-Viscosity sampling valve and a Vacuum Pump, drawing that oil sample will be easier, safer and faster, using the industry leading, OILMISER Sampling Tube.
SV-MB25
SP-HF25
SV-HF25
SP-MB25
SV-HF25 SP-HF25
VP-SP38
JLM Systems Limited 23091 Westminster Highway Richmond, BC Canada V6V 1B9
Toll Free: 1-888-RENU OIL(736-8645) Phone: 604-521-3248 Fax: 604-521-1244 E-mail: info@oilmiser.com
Technology
OILMISER 3 Piece Sampling Tubes More Choice More Flexibility More Standardization
www.oilmiser.com
OILMISER 3 Piece Sampling Tubes No bushings, fewer leak points " ID S.S. Pitot Tube, Any Length
OILMISER 3 Piece Sampling Tubes Standard Pipe, " NPT to 1" NPT SAE ORing Boss, Dash -6 to 24
"
NPT
1"
NPT
"
NPT
1"
NPT
"
NPT
1" "
NPT
SAE-6 ORB
SAE-16 ORB
NPT
" NPT
Male
" NPT
Male
JLM Systems Limited 23091 Westminster Highway Richmond, BC Canada V6V 1B9
Toll Free: 1-888-RENU OIL(736-8645) Phone: 604-521-3248 Fax: 604-521-1244 E-mail: info@oilmiser.com
Technology
www.oilmiser.com
OILMISER 6100 Series Oil Sampling Sandwich Plates for SAE 4 Bolt Flanges
SPK-6110-12 SPK-6110-16
SPK-20
/16-14 x 2" N1470-222
SPK-24
-13 x 3" N1470-225
SPK-32
-13 x 3" N1470-228
SPK-40
-13 x 3" N1470-232
SPK-48
-11 x 3" N1470-237
A Standard SPK 6100 Kit Includes the ORing, 4 Socket Head Cap Screws, and a " NPT (female) Pipe Port for the sampling valve Order the Oil Sampling valves separately. i.e. # SV- MB25 For the 360 Swivel Adaptor add -S90 to part number When ordered with the mid stream pitot tube option the sampling valve is included. i.e. SPK-6120-16 STMB25 (1" Code 61)
SPK-6120-12 SPK-6120-16 SPK-6120-20 SPK-6120-24 SPK-6120-32 SPK-6120-40 SPK-6120-12-STMB25 SPK-6120-16-STMB25 SPK-6120-48 SPK-6120-56 SPK-6120-20-STMB25
Sandwich Plate c/w SSt. Pitot Tube & Minimess Sample Valve Sandwich Plate c/w SSt. Pitot Tube & Minimess Sample Valve Sandwich Plate c/w SSt. Pitot Tube & Minimess Sample Valve Sandwich Plate c/w SSt. Pitot Tube & Minimess Sample Valve Sandwich Plate c/w SSt. Pitot Tube & Minimess Sample Valve
SPK-6120-24-STMB25 SPK-6120-64
All SPK-STMB25 Kits use the OILMISER 3 piece pitot tube principel. The OILMISER TOT-05025 is used to extract or position the pitot tube
SPK-6120-32-STMB25
JLM Systems Limited 23091 Westminster Highway Richmond, BC Canada V6V 1B9
Toll Free: 1-888-RENU OIL(736-8645) Phone: 604-521-3248 Fax: 604-521-1244 E-mail: info@oilmiser.com
Technology
www.oilmiser.com
The OILMISER SV-PT starts with all the standard features normally found in conventional oil sampling valves: 1. a plated steel threaded body with a standard male pipe thread. 2. a plated steel hex cap tethered to the body with a chain. 3. a raised male threaded boss that mates with the steel cap.
Patent Pending
The similarities end when the sealed hex cap is removed. A cavity is machined into the raised boss . Held captive within this cavity is a tube seal/ wiper and a brass gland bushing. This presents a well defined and very clean access point for inserting the standard " OD plastic sampling tube or the OILMISER stainless steel Pass-Thru Probe (PTP), directly into the interior of the machinery.
Patent Pending
When the oil sample has been drawn with a vacuum pump, the plastic sampling tube or the OILMISER pass-thru probe is withdrawn. The tube seal/wiper strips any residual lubricating oil from the outside surface of the sampling tube, leaving it virtually free of any dirt collecting oil film. When the hex cap is replaced, the oring body & cap seal plus an internal stainless steel plug restores the integrity of the machine. Outside contamination cant get inside and inside lubricating oil cant get outside. Drawing oil samples is now quick, clean, safe and reliable.
OILMISER Sampling Valves with Pass-Thru Technology
Part No. SV-PT025 SV-PT038 SV-PT050 SV-PT075 PTP-2510 PTP-2515 PTP-2520 Description Pass-Thru sampling valve x " NPT male pipe Pass-Thru sampling valve x " NPT male pipe Pass-Thru sampling valve x " NPT male pipe Pass-Thru sampling valve x " NPT male pipe Pass-Thru Probe" OD Stainless Steel x10" long Pass-Thru Probe" OD Stainless Steel x15" long Pass-Thru Probe" OD Stainless Steel x20" long Contact Factory for Price and Delivery
JLM Systems Limited 23091 Westminster Highway Richmond, BC Canada V6V 1B9
Toll Free: 1-888-RENU OIL(736-8645) Phone: 604-521-3248 Fax: 604-521-1244 E-mail: info@oilmiser.com