Introduction
Table of Contents
Abstract..................................................................................................................................................... 2 References................................................................................................................................................. 3 Advantages of FTTx and PON..................................................................................................................................... 4 Components of a PON System.................................................................................................................................... 5 PON Installation................................................................................................................................................... 6 PON Specifications............................................................................................................................................ 7 PON Measurement Parameters................................................................................................................................... 8 PON Troubleshooting.................................................................................................................................................. 10 Selecting the Right Testing Instrument........................................................................................................................ 11 Conclusion................................................................................................................................................................... 13

Abstract
Testing fiber-to-the-X (FTTx) networks that include passive optical network (PON) architectures presents unique challenges to service providers. During installation, the network must meet certain standards parameters. Once the FTTx network is deployed, each subscriber connection requires additional tests to ensure service quality. Maintaining the operation of the PON network and troubleshooting potential problems also requires specialized testing procedures and equipment. Anritsu offers a complete line of FTTx and PON test equipment to ensure your networks will perform at their highest levels. The MT9083 Series OTDRs are high performance, all-in-one testing tools to ensure the quality of your optical fibers including PONs featuring up to a 1x128 split. The MT9090A with MU909011A Fault Locator module is the first tester designed specifically for short fiber such as drop cables.

References Mobile/Wireless
B-PON For more information on ongoing PON Recommendation activities, including Gigabit-PON (G-PON), please check the ITU-T Study Group 15 website at: www.itu.int/ITU-T/com15 G.983.1 Broadband optical access systems based on Passive Optical Networks Specifies an optical access system with symmetrical line rates of 155.520 or 622.080 Mbit/s and asymmetrical line rates of 155.520Mbit/s upstream and 622.080 Mbit/s downstream. G.983.2 ONT management and control interface specification for B-PON Specifies requirements for the OMCI, managed entities of a protocol-independent Management Information Base and protocol/detailed messages for the ONT management and control channel. G.983.3 A broadband optical access system with increased service capability by wavelength allocation Adds an additional wavelength band to a G.983.1 B-PON to enable the distribution of unidirectional or bidirectional video broadcast or data services. G.983.4 A broadband optical access system with increased service capability using dynamic bandwidth assignment Specifies the enhancements to a G.983.1 B-PON to allow the use of dynamic bandwidth assignment. G.983.5 A broadband optical access system with enhanced survivability Specifies protection features for a G.983.1 B-PON. G.983.6 ONT management and control interface specifications for B-PON system with protection features Specifies the OMCI for a B-PON system with protection features. G.983.7 ONT management and control interface specification for dynamic bandwidth assignment (DBA) B-PON system Specifies the OMCI for a B-PON system using dynamic bandwidth assignment. G-PON For more information on ongoing G-PON Recommendation activities, please check the ITU-T Study Group 15 website at: www.itu.int/ITU-T/com15 G.984.1, Gigabit-capable Passive Optical Networks (G-PON): General characteristics This Recommendation provides examples of services, User Network Interfaces (UNI) and Service Node Interfaces (SNI) that are required by network operators. In addition, it shows the principal deployment configuration. Wherever possible, this Recommendation maintains characteristics from the ITU-T G.982 and G.983.x series Recommendations in order to promote backward compatibility with existing Optical Distribution Networks (ODN) that comply with these Recommendations. G.984.2, Gigabit-capable Passive Optical Networks (G-PON): Physical Media Dependent (PMD) layer specification This Recommendation specifies the physical layer requirements and specifications for the Physical Media Dependent (PMD) layer. It covers systems with nominal line rates of 1244.160 Mbit/s and 2488.320 Mbit/s in the downstream direction and 155.520 Mbit/s, 622.080 Mbit/s, 1244.160 Mbit/s and 2488.320 Mbit/s in the upstream direction. Both symmetrical and asymmetrical (upstream / downstream) Gigabit-capable Passive Optical Network (G-PON) systems are described. G.984.3, Gigabit-capable Passive Optical Networks (G-PON): Transmission Convergence Layer Specification This Recommendation specifies the frame format, media access control method, ranging method, OAM functionality and security in GPON networks.

w w w. a n r i t s u . c o m

Advantages
Advantage of FTTx and PON
Service providers are running optical fiber much deeper into the access network in order to deliver higher bandwidth that makes it possible to offer multiple high performance voice, video and data services to customers. The diffusion of fiber into the access network is often called the Fiber-to-the-X (FTTx) network. There are two basic types of FTTx architectures. In a point to point (P2P) network, laser transmitters in the central office (CO) are dedicated to individual users. A more popular alternative, because of its high performance to price ratio, is a passive optical network (PON) in which the transmitters are shared among multiple users.

FTTx and PON


FTTx networks are designed to deliver high performance Triple Play services to users by bringing fiber directly to or near the customer premises.

FTTx Acronyms
FTTH - fiber to the home FTTP - fiber to the premise FTTU - fiber to the user FTTC - fiber to the curb/cabinet FTTB - fiber to the business FTTN - fiber to the node

Figure 1: Types of FTTx


The PON architecture is commonly used for FTTx networks because it employs optical splitters to deliver signals to multiple users without conversion or intervention. Unlike traditional networks where services are direct point-to-point links between customer and provider, PONs share a common distribution segment before being split to several users, therefore reducing installation costs. FTTx networks feature active and passive components. The OLT and ONT segments are active while the PON, as the name states, is passive. PONs enable service providers to provide virtually unlimited bandwidth for applications such as high definition television (HDTV), video on demand (VOD), streaming video, gaming and peer-to-peer (P2P) file sharing that require large amounts of bandwidth. PON equipment costs have dropped to the point where they are competitive with copper networks and new products such as bend-resistant fibers and easier-to-use cable management systems have simplified PON installation. With each 1080 pixel HDTV channel requiring up to 6 megabytes, triple play services typically require about 20 MB per home, just about the limit of what can be provided with copper but well within fiber's capabilities.

| FTTx/PON Resource Guide

Components
Components of a PON System

Figure 2: Possible PON Architectures

The termination equipment for a PON system in the central office (CO) is called the Optical Line Termination (OLT) which multiplexes voice and video for downstream transmission to the splitter. The OLT uses a traditional card and chassis architecture, housing the laser transmitters that are shared among the users. The OLT combines the signals into a single fiber at the CO using WDM techniques. A fiber distribution frame (FDF) at the CO integrates a number of OLTs together with splicing trays and connectors that connect the OLT to the backbone network.

Components of a PON System


The distribution cable terminates at the OLT and runs to the pad or pole mounted fiber distribution hub (FDH) which houses the optical splitter. The splitter is a passive component that requires no maintenance and no power but has a high relatively high insertion loss, typically 15 dB for 32 port splitter. The FDH typically accommodates up to 10 splitters each of which typically has up to 32 branches. Applications where the fiber runs all the way to the customer premise normally use a distribution cable running from the FDH to the Fiber Distribution Pedestal (FDP) which serves as a splice or connection point close to the customer premises and contains fiber management. A drop cable with a typical length of several hundred feet runs from the FDP to the ONT in the customer premises. The ONT splits the signal into the voice, video and data services used by the customer. The ONT uses various interfaces including RJ-11 twisted pair jacks for voice service, RJ-45 Ethernet jacks for high speed data and 75 ohm coaxial ports for video service. In applications in which the fiber terminates prior to the CP and then converts to some other transmission medium, the distribution cable runs from the FDH and terminates at an Optical Network Unit (ONU) located at the curb (Fiber to the Curb (FTTC)) or cabinet (Fiber-to-the-Cabinet or FTTCab). In some cases, the distribution cable is deployed to the customer premises. In other cases, the drop cable runs all the way from the FDH to the customer premises.

w w w. a n r i t s u . c o m

Components

Figure 3; Typical PON Layout with a Video Overlay

PON Installation

Figure 4: Possible PON Architecture

Typically PONs are installed in two segments by two different groups with different testing requirements. The first phase is the installation of the feeder cable from the CO to the FDH or FDP and the distribution cable to the FDP. This segment is typically installed by a contractor and is certified after installation by measuring the total loss and evaluating splices and connectors. This segment requires a PON capable optical time domain reflectometers (OTDR) with high dynamic range and the ability to test multiple wavelengths and provide detailed reporting needed for certification. The second last mile segment runs from the FDH or FDP to the ONT. Testing during installation and maintenance typically requires a fault location, connectivity check and isolation. The highly capable instruments used to certify the feeder cable are not required for testing this segment and so it is possible to use a less expensive and more user-friendly drop cable fault locator.

| FTTx/PON Resource Guide

Specifications
PON Specifications
The International Telecommunications Union Standardization Sector (ITU-T) has created several standards for optical access systems based on the PON architecture. Broadband PON (BPON) uses Asynchronous Transfer Mode (ATM) cells for transmission to a maximum of 32 customers and has a maximum access speed of 155 Mbps upstream and 622 Mb/s downstream. Gigabit PON (GPON) was later developed to increase access speed to 1.2 Gbps downstream and 622 Mbps upstream, making it possible to serve a maximum of 128 customers. The Ethernet PON (EPON) standard uses standard 802.3 frames with symmetric 1 Gbps upstream and downstream rates. Since EPON is active Ethernet based it uses a powered switch in the outside plant and dedicated switches and fiber runs. Advantages of EPON include the fact that no encryption is needed since lines aren't shared and that bandwidth can be easily changed. On the other hand, EPON is more expensive due to switch power costs and dedicated fibers. DPON is a DOCSIS standard based for multiple system operators (MSOs) that allows use of the current head-end and customer premises equipment.

Figure 5: PON Architecture (BPON)

The Typical Network Planning Specifications for a PON System


Video transmission downstream from the CO OLT to the premise ONT is 1550nm at 622Mbits/sec (BPON) or 1.2Gbits/sec (GPON). Voice/data and IP Video (if used) transmission downstream from the CO OLT to the premise is 1490nm at 622Mbits/sec (BPON) or 1.2Gbits/sec (GPON). Transmission upstream from the premise ONT to the CO OLT is 1310nm at 155Mbits/sec (BPON) or 622Mbits/sec (GPON). Most PONs today are using an ATM protocol with access to bandwidth using time division multiple access (TDMA) upstream and, TDM downstream. IP and Gigabit Ethernet based PON systems are also beginning to see widespread deployment. Maximum End-to-End Length 20 km determined by the 1310 nm optical budget 25 dB - 12 dB splitter = 13 dB 13 dB - 6 dB (connector and splice loss) = 7 dB 7 dB / 0.35 dB/km (1310 nm fiber loss) = 20 km 7 dB / 0.20 dB/km (1550 nm fiber loss) = 35 km

Total End-to-End Optical Budget 25 dB for a Class B PON Network 30 dB for a Class C PON Network

PONs present major testing challenges, largely because the presence of the relatively high-loss optical splitter means that testing from the CO does not provide a dedicated optical path as with traditional point-to-point fiber networks. The PON is shared by multiple customers so the situation frequently exists where one or a few customers are down while the rest are still operating. This makes troubleshooting more difficult to perform because it must be done without disrupting service to the customers that are up and running. Another complicating factor is that 1490 nm and 1550 nm transmissions are both possible in the downstream transmission while 1310 nm upstream transmissions are not present unless the downstream transmission is there to stimulate it.

w w w. a n r i t s u . c o m

Parameters
PON Measurement Parameters
A number of parameters must be measured during installation and maintenance and verified against network specifications. The end-to-end loss budget of the fiber span at each transmission wavelength is the most crucial measurement of the physical medium. The measurement should be taken at each transmission wavelength and should include the end connectors. To ensure accurate results, the test should be performed directionally using a loss test set (LTS) with the results averaged together to yield the true loss budget.

End connectors should be tested for both loss and reflectance using an OTDR with a lead-in fiber against the individual connector specifications. If the loss or reflectance of an individual connector does not meet specifications then it should be repaired or replaced. Documenting the location of each connector is important for future maintenance of the network. If problems arise on the network, knowing the exact location of each connection point will significantly reduce troubleshooting time.

Each individual average splice loss should also be verified bi-directionally for maximum loss values, even if the total end-to-end loss passes the network specification. If the loss of an individual splice does not meet specification, it may signify a poor quality splice that could cause future problems in the network resulting in network down time and maintenance costs. This must be done using an OTDR on each feeder fiber before termination to the PON coupler.

The quality of the individual fibers between splice points should be verified to meet average loss specifications from the supplier at the specified wavelength. Macrobends that may have been introduced during cable installation can be identified by comparing a shorter 1310 nm OTDR trace with a longer wavelength 1550 nm ODTR trace on the same fiber. If the losses vary by more than 0.3 dB on the same splice point between different wavelengths, this indicates that macrobends may be present.

| FTTx/PON Resource Guide

PON Measurements Parameters


Optical return loss (ORL) should be measured between the termination fibers located at the customer premise (ONT or ONU) and the CO (OLT) after the entire network is completed from end to end but before connection to any termination equipment. Typical ORL specifications values are +30 dB to +35 dB. In deploying new connections to a live PON system, verify optical power at 1550 and 1490 nm and splice the assigned drop cables to their respective coupler outputs. At the customer premises, test for live PON receiver power with an optical power meter at the 1550 nm setting with a 1550 nm pass filter. If the optical power meets the approved -28 dBm level, connect the ONT. A green light will confirm OLT and ONT communication and equipment operation can be verified.

w w w. a n r i t s u . c o m

Troubleshooting
PON Troubleshooting
If all customers connected to a PON system are out of service, testing can proceed at the CO without danger of interfering with existing service. System diagnostics will usually detect a problem with the OLT and the solution is normally a line-card replacement. The OLT manager will usually identify a broken fiber on the main leg as all branches associated with the OLT will become nonresponsive. Troubleshooting can then proceed with an OTDR or a simpler break indicator.

Figure 6: PON Troubleshooting Overview


Figure 6 outlines a methodology for troubleshooting PON networks in the more difficult situation where one or some customers connected to the PON are out of service. When a fault occurs in the subscriber's FTTH service, if other subscribers sharing the OLT are not experiencing the same fault, then the problem is either in the drop cable between the FDH and the ONU/ONT, in the ONU/ONT or in the subscriber's home network. The technician should begin by disconnecting the optical fiber from the ONU/ONT and checking the optical signal level with a power meter. If no power is measured on the drop cable, the chances are that the problem is either a break in the fiber or a high loss event such as a bad splice. Since no power is being received at this ONT location, there is no danger of interfering with traffic on the PON when testing the fiber using an OTDR. But to be safe it's a good idea to troubleshoot with an OTDR using the 1650 nm wavelength to avoid interfering with the ONT in the event of a mistake. If the optical power level is lower than the specification, there is a good chance that there is a break or damage in the drop cable. Maintenance of a PON drop cable requires care when the rest of the network is still in service. One approach is to isolate the drop cable under test from the rest of the network but this is not easy because the connections are often high on utility poles and wires, and disconnecting fiber splices is difficult. The solution is to use a short wavelength OTDR such as the Anritsu MT9090A or MT9083 series with test pulses at a wavelength of 780 nm. Testing from the subscriber's side at 780 nm has no effect at all on the in-service customers. The dynamic range at 780 nm is 8 dB so faults in a 2 km or shorter drop cable can be accurately pinpointed. If the power is OK, then test down the stream from the coupler with an OTDR and bare fiber adapter to pinpoint the attenuation.

10 | FTTx/PON Resource Guide

Selection
Selecting the Right Testing Instruments
An OTDR is the universal tool used to pinpoint faults and certify the workmanship in a fiber installation. OTDRs find and characterize both reflective and nonreflective events in optical fiber runs by sending laser pulses of different widths. There are two main parameters that measure the performance of an OTDR. The dynamic range determines the length of fiber link that the OTDR can test - higher values enable testing longer lengths. The event dead zone is the minimum distance of separation between two different optical reflective events that the OTDR can resolve - shorter values enable resolving more closely spaced events. Dynamic range and event dead zone both increase with longer pulse widths so tuning the OTDR normally requires a tradeoff between these two parameters.

Figure 7: Traces from traditional PON capable OTDRs

Not all OTDRs are capable of testing splitter based PONs. To perform well in measuring and certifying PONs, OTDRs need a small dead zone to allow measurement of near end connectors within the CO in riser cables and at the customer premises. They also need a high dynamic range in order to measure the high losses that are typically involved in PONs. Figure 7 compares the measurements provided by a conventional OTDR (blue) and the Anritsu MT9083, a PON capable OTDR (red). The splitter is easily identified by the large losses at 2.5 km and 2.7 km. The conventional OTDR lacks dynamic range, resulting in a large amount of noise at distances greater than the splitter and making it impossible to accurately test through the splitter. On the other hand, the MT9083 OTDR has no difficulty in testing through the splitter. After initial construction of a PON system it is necessary to accurately and completely characterize the fiber link from the OLT to the FDH and, most important, to measure loss and ORL. A PON-capable OTDR such as the MT9083 makes this task easier through its ability to distinguish between the loss properties of the individual PON branches, making it possible to test the feeder cable from the ONT end.

Figure 8: MT9083 offers excellent resolution

w w w. a n r i t s u . c o m

11

Selection
Selecting the right testing instruments

A dual mode design enables the MT9083 OTDR series to offer excellent dynamic range and dead zone resolution. The user can simply select high resolution or enhanced range mode based on the task at hand. When HR mode is selected, the MT9083 series provides good measurement range with an industry leading deadzone of less than 1 meter. When ER mode is selected, the MT9083 provides unparalleled performance for measurement distance, measurement speed and deadzone. The MT9083B and MT9083C provide up to 45 dB dynamic range, providing a measurement range of over 200 km and making it possible to test a 100 km fiber in less than 10 seconds. The combination of a high dynamic range with a short pulse makes it possible to test the entire fiber path through the splitter. Splitters up to a single 1x128 or closely spaced, cascaded splitters are completely and accurately measured with industry leading resolution. The MT9083 series also offers a full SCPI command support for remote operations or automated testing. Traditional tools have not provided the right solution for the technicians charged with maintaining and troubleshooting local access networks. Handheld OTDRs and Fault Locators lack the resolution needed for short drop cable spans while mini-OTDRs were too large, too expensive and too complicated. The new MT9090A from Anritsu finally addresses this need by providing all of the features and performance required for installation and maintenance of short fibers in a compact, modular test set. Realizing that short fiber premise applications such as FTTx drop cables, intra-building riser cables and cell towers have different testing requirements, Anritsu designed the MT9090A from the ground up. It features 5 cm resolution for accurate mapping of events, deadzones of less than 1 meter (3 feet) and a built-in 10 m (30 ft) launch fiber to ensure everything is evaluated. Since multiple users share the common feed fiber, FTTx maintenance becomes difficult when only one or two users are down. To address this need, Anritsu also offers a 780 nm Fault Locator module that can be used to troubleshoot in-service FTTx networks without costly filters and without disruption to other customers.

MT9083 Series

MT9090A/MU909011A Fault Locator

12 | FTTx/PON Resource Guide

Conclusion
FTTx networks with PON architectures provide the opportunity to deliver dramatic increases in bandwidth. Service providers are using this bandwidth to deliver new value-added services such as HDTV, VOD and gaming to customers. But the deployment and maintenance of PON architectures presents some significant challenges to service providers. For example, the presence of the splitter complicates testing because there is no longer a dedicated optical path from CO to the customer. Installation of a PON requires carefully measuring key performance parameters against network specifications. Once the FTTP network is deployed, each subscriber connection requires additional tests to ensure service quality. Overcoming testing challenges is critical to delivering high-performance and reliable service to customers at a low cost. The correct test equipment and knowledge can quickly result in a trouble-free FTTx network. Anritsu offers the expertise and the optimized FTTx test equipment to meet these challenges.

w w w. a n r i t s u . c o m

13

Specifications are subject to change without notice.

Anritsu Corporation
5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1238

Italy

Anritsu S.p.A.

Singapore

Anritsu Pte. Ltd.

U.S.A. Anritsu Company


1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A. Toll Free: 1-800-267-4878 Phone: +1- 972-644-1777 Fax: +1-972-671-1877

Via Elio Vittorini 129, 00144 Roma, Italy Phone: +39-6-509-9711 Fax: +39-6-502-2425

Sweden Finland

60 Alexandra Terrace, #02-08, The Comtech (Lobby A) Singapore 118502 Phone: +65-6282-2400 Fax: +65-6282-2533

Anritsu AB

Borgafjordsgatan 13, 164 40 KISTA, Sweden Phone: +46-8-534-707-00 Fax: +46-8-534-707-30

India

Anritsu Pte. Ltd. India Branch Office

Canada Anritsu Electronics Ltd.


700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006

Anritsu AB

Teknobulevardi 3-5, FI-01530 VANTAA, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111

3rd Floor, Shri Lakshminarayan Niwas, #2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, India Phone: +91-80-4058-1300 Fax: +91-80-4058-1301

P.R. China (Hong Kong)


Anritsu Company Ltd.
Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong Phone: +852-2301-4980 Fax: +852-2301-3545

Denmark Spain

Anritsu Eletrnica Ltda.


Praca Amadeu Amaral, 27 - 1 Andar 01327-010-Paraiso-So Paulo-Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940

Brazil

Anritsu A/S

Kirkebjerg All 90, DK-2605 Brndby, Denmark Phone: +45-72112200 Fax: +45-72112210

P.R. China (Beijing)

Anritsu Company, S.A. de C.V.


Av. Ejrcito Nacional No. 579 Piso 9, Col. Granada 11520 Mxico, D.F., Mxico Phone: +52-55-1101-2370 Fax: +52-55-5254-3147

Mexico

Anritsu EMEA Ltd. Oficina de Representacin en Espaa

Anritsu Company Ltd. Beijing Representative Office

Edificio Veganova Avda de la Vega, n 1 (edf 8, pl 1, of 8) 28108 ALCOBENDAS - Madrid, Spain Phone: +34-914905761 Fax: +34-914905762

Room 2008, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 100004, P.R. China Phone: +86-10-6590-9230 Fax: +86-10-6590-9235

Anritsu EMEA Ltd.


200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582-731303

U.K.

Russia

Korea

Anritsu EMEA Ltd. Representation Office in Russia

Anritsu Corporation, Ltd.

Anritsu S.A.
16/18 avenue du Qubec-SILIC 720 91961 COURTABOEUF CEDEX, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65

France

Tverskaya str. 16/2, bld. 1, 7th floor. Russia, 125009, Moscow Phone: +7-495-363-1694 Fax: +7-495-935-8962

8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604

United Arab Emirates


Anritsu EMEA Ltd. Dubai Liaison Office
P O Box 500413 - Dubai Internet City Al Thuraya Building, Tower 1, Suit 701, 7th Floor Dubai, United Arab Emirates Phone: +971-4-3670352 Fax: +971-4-3688460

Australia

Anritsu Pty. Ltd.

Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255

Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1 81829 Mnchen, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55

Germany

Taiwan

Anritsu Company Inc.

7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817

Please Contact:

Anritsu All trademarks are registered trademarks of their respective companies. Data subject to change without notice. For the latest specifications and products visit www.anritsu.com

Rev 1 0609 10/2010

Das könnte Ihnen auch gefallen