Sie sind auf Seite 1von 104

Control Systems Laboratory Manual / II EEE, IV SEM

VELS UNIVERSITY
SCHOOL OF ENGINEERING

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

LABORATORY MANUAL
CLASS SEMESTER SUBJECT : II YEAR EEE : IV : CONTROL SYSTEMS LABORATORY
Assistant Professor EEE Department

STAFF IN-CHARGE : V.Arivumani

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

CONTROL SYSTEMS LABORATORY MANUAL

NAME CLASS SEMESTER ROLL NUMBER

: : : :

REGISTER NUMBER :

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

INDEX
S. No. Date Title of Experiment Page No. Marks Signature

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

SYLLABUS EE2257 CONTROL SYSTEM LABORATORY


1. 2. 3. 4. 5. 6. 7. 8. Determination of transfer function of DC Servomotor Determination of transfer function of AC Servomotor. Analog simulation of Type - 0 and Type 1 systems Determination of transfer function of DC Generator Determination of transfer function of DC Motor Stability analysis of linear systems DC and AC position control systems Stepper motor control system 9. Digital simulation of first order systems 10. Digital simulation of second order systems P = 45 Total = 45 DETAILED SYLLABUS 1. Determination of Transfer Function Parameters of a DC Servo Motor
Aim To derive the transfer function of the given D.C Servomotor and experimentally determine the transfer function parameters Exercise 1. Derive the transfer function from basic principles for a separately excited DC motor. 2. Determine the armature and field parameters by conducting suitable experiments. 3. Determine the mechanical parameter by conducting suitable experiments. 4. Plot the frequency response. Equipment 1. DC servo motor 2. Tachometer 3. Multimeter 4. Stop watch 2. : field separately excited loading facility variable voltage source - 1 No : 1 No : 2 Nos : 1 No

0 0 3 2

Determination of Transfer Function Parameters of AC Servo Motor


Aim To derive the transfer function of the given A.C Servo Motor and experimentally determine the transfer function parameters

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

Exercise 1. Derive the transfer function of the AC Servo Motor from basic Principles. 2. Obtain the D.C gain by operating at rated speed. 3. Determine the time constant (mechanical) 4. Plot the frequency response Equipment 1. AC Servo Motor 2. Tachometer 3. Stopwatch 4. Voltmeter : Minimum of 100w necessary sources for main winding and control winding 1 No : 1 No : 1 No : 1 No

3.

Analog Simulation of Type-0 And Type-1 System


Aim To simulate the time response characteristics of I order and II order, type 0 and type-1 systems. Exercise 1. Obtain the time response characteristics of type 0 and type-1, I order and II order systems mathematically. 2. Simulate practically the time response characteristics using analog rigged up modules. 3. Identify the real time system with similar characteristics. Equipment 1. Rigged up models of type-0 and type-1 system using analog components. 2. Variable frequency square wave generator and a normal CRO - 1 No (or) DC source and storage Oscilloscope - 1 No

4.

Determination of Transfer function of DC Generator


Aim To determine the transfer function of DC generator Exercise 1. Obtain the transfer function of DC generator by calculating and gain Equipment 1. DC Generator 2. Tachometer 3. Various meters

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM 4. Stop watch

5.

Determination of Transfer function of DC Motor


Aim To determine the transfer function of DC motor Exercise 1. Obtain the transfer function of DC motor by calculating and gain Equipment 1. DC Motor 2. Tachometer 3. Various meters 4. Stop watch

6.

Stability Analysis of Linear Systems


Aim To analyse the stability of linear systems using Bode / Root locus / Nyquist plot Exercise 1. Write a program to obtain the Bode plot / Root locus / Nyquist plot for the given system 2. Access the stability of the given system using the plots obtained 3. Compare the usage of various plots in assessing stability Equipment 1. System with MATLAB / MATHCAD / equivalent software - 3 user license

7.

DC and AC position Control Systems


Aim To study the AC and DC position control system and draw the error characteristics between set point and error. Exercise 1. To study various position control systems and calculate the error between set point and output position 2. To measure outputs at various points (between stages) Equipment 1. AC and DC position control kit with DC servo motor. 2. Power transistor 3. Adder

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

8.

Stepper Motor Control System


Aim To study the working of stepper motor Exercise 1. To verify the working of the stepper motor rotation using microprocessor. Equipment 1. Stepping motor 2. Microprocessor kit 3. Interfacing card 4. Power supply

9.

Digital Simulation of First Order System


Aim To digitally simulate the time response characteristics of first -order system Exercise 1. Write a program or build the block diagram model using the given software. 2. Obtain the impulse, step and sinusoidal response characteristics. 3. Identify real time systems with similar characteristics. Equipment 1. System with MATLAB / MATHCAD (or) equivalent software - minimum 3 user license.

10.

Digital Simulation of Second Order Systems


Aim To digitally simulate the time response characteristics of second -order system Exercise 1. Write a program or build the block diagram model using the given software. 2. Obtain the impulse, step and sinusoidal response characteristics. 3. Identify real time systems with similar characteristics. Equipment System with MATLAB / MATHCAD (or) equivalent software - minimum 3 user license.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

LIST OF EXPERIMENTS
FIRST CYCLE: 1. Determination of transfer function of armature controlled DC servomotor. 2. Determination of transfer function of field controlled DC servomotor. 3. Determination of transfer function of AC servomotor.
4. Determination of transfer function of separately excited DC generator.

5. Determination of transfer function of DC motor. 6. DC position control system. SECOND CYCLE:


7. Analog simulation of Type-0 and Type-1 systems.

8. Digital simulation of first order systems. 9. Digital simulation of second order systems
10. Stability analysis of linear systems.

11. Stepper motor control system.


12. AC position control system.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

Expt. No:

Date: DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR

AIM: To determine the transfer function of armature controlled DC servo motor. APPARATUS / INSTRUMENTS REQUIRED: S. No 1. 2. 3. 4. 5. 6. 7. Description DC servo motor trainer kit DC servo motor Rheostat Ammeter Voltmeter Stopwatch Patch cords Range 500/1A (0-1)A (0-100) mA (0300) V (075) V Type Quantity 1 1 1 1 1 1 1 1 As required

MC MI MC MI

THEORY: In servo applications a DC motor is required to produce rapid accelerations from standstill. Therefore the physical requirements of such a motor are low inertia and high starting torque. Low inertia is attained with reduced armature diameter with a consequent increase in the armature length such that the desired power output is achieved. Thus, except for minor differences in constructional features a DC servomotor is essentially an ordinary DC motor. A DC servomotor is a torque transducer which converts electrical energy into mechanical energy. It is basically a separately excited type DC motor. The torque developed on the motor shaft is directly proportional to the field flux and armature current, Tm = Km Ia. The back emf developed by the motor is Eb = Kb m.. In an armature controlled DC Servo motor, the field winding is supplied with constant current hence the flux remains constant. Therefore these motors are also called as constant magnetic flux motors. Armature control scheme is suitable for large size motors. ARMATURE CONTROLLED DC SERVOMOTOR:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM

FORMULAE USED: Transfer function of the armature controlled DC servomotor is given as

(s) / Va(s) = Km / [s (1+sa)(1+sm ) + (Kb Kt /RaB)]


where Motor gain constant, Km = (Kt/RaB) Motor torque constant, Kt = T / Ia Torque, T in Nm = 9.55 Eb Ia Back emf, Eb in volts = Va Ia Ra Va = Excitation voltage in volts Back emf constant, Kb = Va / Angular velocity in rad/ sec = 2N / 60 Armature time constant, a = La / Ra Armature Inductance, La in H= XLa / 2f XLa in =(Za2 Ra2) Za in = Va2 / Ia2 Armature resistance,Ra in = Va1 / Ia1 Mechanical time constant, m = J / B Moment of inertia, J in Kg m2 / rad = W x (60 / 2 )2 x dt/dN N Stray loss, W in Watts = W x [ t2 / (t1-t2) ] Power absorbed, W in watts = Va Ia t2 is time taken on load in secs t1 is time taken on no load in secs dt is change in time on no load in secs dN is change in speed on no load is rpm N is rated speed in rpm

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

10

Control Systems Laboratory Manual / II EEE, IV SEM

Frictional co-efficient, B in N-m / (rad / sec ) = W / (2N / 60 )2 W = 30 % of Constant loss Constant loss = No load i/p Copper loss No load I/P = V ( Ia + If ) Copper loss = Ia2 Ra N is rated speed in rpm

PROCEDURE: 1. To determine the motor torque constant Kt and Back emf constant Kb: Check whether the MCB is in OFF position in the DC servomotor trainer kit Press the reset button to reset the over speed. Patch the circuit as per the patching diagram. Put the selection button of the trainer kit in the armature control mode. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and apply rated voltage of 220 V to the armature of the servomotor. Note the values of the armature current Ia, armature voltage Va, and speed N. Find the motor torque constant Kt and Back emf constant Kb using the above values. Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: Armature Voltage,Va (V) Armature Current,Ia (A) Speed,N (rpm)

S. No.

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

11

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

12

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE THE MOTOR TORQUE CONSTANT Kt AND BACK EMF CONSTANT Kb

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

13

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 2. To determine armature resistance Ra: Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the armature control mode. The field terminal is left opened. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and apply rated voltage of 220 V to the armature of the servomotor. Note the values of the armature current Ia, armature voltage Va. Find the value of armature resistance Ra using the above values Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: Armature Voltage, Va1 (V) Armature Current, Ia1 (A) Armature resistance, Ra ()

S. No.

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

14

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE ARMATURE RESISTANCE Ra

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

15

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 3. To find armature inductance, La Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the armature control mode. The field terminal is left opened. Switch ON the MCB. Note the values of the armature current Ia, armature voltage Va. Find the value of armature inductance La.using the above values Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: S. No. Armature Voltage, Va2 (V) Armature Current, Ia2 (mA) Armature impedance Za ()

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

16

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE ARMATURE INDUCTANCE, La

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

17

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 4. To determine moment of inertia J and frictional co-efficient B: Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the armature control mode and the DPDT switch in power circuit position. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and adjust the motor to run at rated speed. Note the values of armature current Ia, armature voltage Va, field current If, Speed N. Change the DPDT switch position from power circuit side to load side, simultaneously noting the time taken t1 of the motor to come to rest from rated speed, using a stop watch. Set the potentiometer to minimum position and change the DPDT switch to power circuit side Connect a load of 500 Ohms in the load position Vary the pot and adjust the motor to run at rated speed Change the DPDT switch position from power circuit side to load side, simultaneously noting the time taken t2 of the motor to come to rest from rated speed, using a stop watch. Find the values of moment of inertia J and frictional co-efficient B using the above values

OBSERVATIONS: S. No. Armature Voltage, Va (V) Armature Current, Ia (A) Field Current, If (A) Speed, N (rpm)
t1 (secs) t2 (secs)

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

18

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

19

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE MOMENT OF INERTIA J , FRICTIONAL CO-EFFICIENT B: ( t1 No load)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

20

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE MOMENT OF INERTIA J , FRICTIONAL CO-EFFICIENT B: ( t2 load)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

21

Control Systems Laboratory Manual / II EEE, IV SEM CALCULATIONS:

RESULT: The transfer function of armature controlled DC servomotor is determined as

VIVA-VOCE QUESTIONS: 1. 2. 3. 4. 5. Define transfer function. What is DC servo motor? State the main parts. What is servo mechanism? Is this a closed loop or open loop system .Explain. What is back EMF?

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

22

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No: Date:

DETERMINATION OF TRANSFER FUNCTION PARAMETERS OF FIELD CONTROLLED DC SERVO MOTOR AIM: To determine the transfer function of field controlled DC servo motor. APPARATUS / INSTRUMENTS REQUIRED: S. No 1. 2. 3. 4. 5. 6. 7. Description DC servo motor trainer kit DC servo motor Rheostat Ammeter Voltmeter Stopwatch Patch cords Range 500/1A (0-1)A (0-100) mA (0300) V (075) V Type Quantity 1 1 1 1 1 1 1 1 As required

MC MI MC MI

THEORY: In a field controlled DC Servo motor, the electrical signal is externally applied to the field winding. The armature current is kept constant. In a control system, a controller generates the error signal by comparing the actual o/p with the reference i/p. Such an error signal is no enough to drive the DC motor. Hence it is amplified by the servo amplifier and applied to the field winding. With the help of constant current source, the armature current is maintained constant. When there is change in voltage applied to the field winding, the current through the field winding changes. This changes the flux produced by field winding. This motor has large Lf / Rf ratio, so time constant of this motor is high and it cant give rapid responses to the quick changing control signals. FIELD CONTROLLED MOTOR:

FORMULAE USED: Prepared by V.Arivumani, AP/EEE, Vels University, Chennai 23

Control Systems Laboratory Manual / II EEE, IV SEM Transfer function of field controlled DC servo motor is given as, where (s) / Vf (s) = Km / s (1+sTf) (1+sTm)

Motor gain constant Km = Ktf / Rf B Motor torque constant Ktf in N-m / A = T / If Torque T in N-m = 9.55 Eb Ia / N Back EMF Eb in volts = Va Ia Ra Va = Excitation voltage in volts Armature resistance,Ra in = Va1 / Ia1 Field resistance,Rf in = Vf1 / If1 Field time constant Tf = Lf / Rf Field Inductance,Lf in H= XLf / 2f XLf in = (Zf2 Rf2) Zf in = Vf2 / If2 Mechanical time constant Tm = J / B Moment of inertia J in Kg m2 / rad = W x (60 / 2)2 x dt/dN N Stray loss, W in watts = W x [ t2 / (t1-t2) ] Power absorbed, W in Watts = Va Ia t2 is time taken on load in secs t1 is time taken on no load in secs dt is change in time on no load in secs dN is change in speed on no load is rpm N is rated speed in rpm Frictional co-efficient, B in N-m / (rad / sec ) = W / (2N / 60 )2 W = 30 % of Constant loss Constant loss = No load i/p Copper loss No load I/P = V ( Ia + If ) Copper loss = Ia2 Ra N is rated speed in rpm

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

24

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 1. To determine the motor torque constant Ktf : Check whether the MCB is in OFF position in the DC servomotor trainer kit Press the reset button to reset the over speed. Patch the circuit as per the patching diagram. Put the selection button of the trainer kit in the field control mode. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and apply rated voltage of 220V to the armature of the servomotor. Note the values of the armature current Ia, armature voltage Va, and speed N. Find the motor torque constant Kt f using the above values. Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: Armature Voltage,Va (V) Armature Current,Ia (A) Speed,N (rpm)

S. No.

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

25

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF FIELD CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE THE MOTOR TORQUE CONSTANT Ktf

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

26

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 2. To determine armature resistance Ra: Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the armature control mode. The field terminal is left opened. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and apply rated voltage of 220V to the armature of the servomotor. Note the values of the armature current Ia, armature voltage Va. Find the value of armature resistance Ra using the above values Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: Armature Voltage, Va1 (V) Armature Current, Ia1 (A) Armature Resistance, Ra ()

S. No.

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

27

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF FIELD CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE ARMATURE RESISTANCE Ra

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

28

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 3. To determine field resistance Rf: Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the field control mode. The armature terminal is left opened. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and apply rated voltage of 220V to the field of the servomotor. Note the values of the field current If, field voltage Vf. Find the value of field resistance Rf using the above values Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: Field Voltage, Va1 (V) Field Current, Ia1 (A) Field Resistance, Rf ()

S. No.

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

29

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF FIELD CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE FIELD RESISTANCE RF

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

30

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 4. To determine Field Inductance, Lf Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the field control mode. The armature terminal is left opened. Switch ON the MCB. Note the values of the field current If2, field voltageVf2. Find the value of field inductance Lf.using the above values Note: If the voltmeter and ammeter in the trainer kit is found not working external meters of suitable range can be used. OBSERVATIONS: S. No. Field Voltage, Vf2 (V) Field Current, If2 (mA) Field Impedance Zf ()

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

31

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF FIELD CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE FIELD INDUCTANCE, LF

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

32

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 5. To determine moment of inertia J and frictional co-efficient B: Check whether the MCB is in OFF position in the DC servomotor trainer kit Patch the circuit as per the patching diagram Put the selection button of the trainer kit in the armature control mode and the DPDT switch in power circuit position. Check the position of the potentiometer; let it initially be in minimum position. Switch ON the MCB. Vary the pot and adjust the motor to run at rated speed. Note the values of armature current Ia, armature voltage Va, field current If, Speed N. Change the DPDT switch position from power circuit side to load side, simultaneously noting the time taken t1 of the motor to come to rest from rated speed, using a stop watch. Set the potentiometer to minimum position and change the DPDT switch to power circuit side Connect a load of 500 Ohms in the load position Vary the pot and adjust the motor to run at rated speed Change the DPDT switch position from power circuit side to load side, simultaneously noting the time taken t2 of the motor to come to rest from rated speed, using a stop watch. Find the values of moment of inertia J and frictional co-efficient B using the above values

OBSERVATIONS: S. No Armature Voltage, Va (V) Armature Current, Ia (A) Field Current, If (A) Speed, N (rpm)
t1 (secs) t2 (secs)

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

33

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

34

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF FIELD CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE MOMENT OF INERTIA J , FRICTIONAL CO-EFFICIENT B: ( t1 No load)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

35

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF ARMATURE CONTROLLED DC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE MOMENT OF INERTIA J , FRICTIONAL CO-EFFICIENT B: ( t2 load)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

36

Control Systems Laboratory Manual / II EEE, IV SEM CALCULATIONS:

RESULT: The transfer function of field controlled DC servomotor is determined as

VIVA-VOCE QUESTIONS: 1. What are the main parts of a DC servo motor? 2. Name the two types of servo motor. 3. State the advantages and disadvantages of a DC servo motor. 4. Give the applications of DC servomotor. 5. What is servo mechanism? 6. What do you mean by field controlled DC servo motor?

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

37

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No: Date: DETERMINATION OF TRANSFER FUNCTION OF AC SERVO MOTOR AIM: To derive the transfer function of the given AC Servomotor. APPARATUS / INSTRUMENTS REQUIRED: S. No 1. 2. 3. 4. 5. Description AC servo motor trainer kit AC servo motor Ammeter Voltmeter Patch cords Range (0-1) A (0-100) mA (0300) V (075) V Type MC MI MC MI Quantity 1 1 1 1 1 1 As required

THEORY: An AC servo motor is basically a two phase induction motor with some special design features. The stator consists of two pole pairs (A-B and C-D) mounted on the inner periphery of the stator, such that their axes are at an angle of 90o in space. Each pole pair carries a winding, one winding is called reference winding and other is called a control winding. The exciting current in the winding should have a phase displacement of 90o. The supply used to drive the motor is single phase and so a phase advancing capacitor is connected to one of the phase to produce a phase difference of 90o.The rotor construction is usually squirrel cage or drag-cup type. The rotor bars are placed on the slots and short-circuited at both ends by end rings. The diameter of the rotor is kept small in order to reduce inertia and to obtain good accelerating characteristics. The drag cup construction is employed for very low inertia applications. In this type of construction the rotor will be in the form of hollow cylinder made of aluminium. The aluminium cylinder itself acts as short-circuited rotor conductors. Electrically both the types of rotor are identical.

WORKING PRINCIPLE :
The stator windings are excited by voltages of equal magnitude and 90o phase difference. These results in exciting currents i1 and i2 that are phase displaced by 90o and have equal values. These currents give rise to a rotating magnetic field of constant magnitude. The direction of rotation depends on the phase relationship of the two currents (or voltages). This rotating magnetic field sweeps over the rotor conductors. The rotor conductor experience a change in flux and so voltages are induced rotor conductors. This voltage circulates currents in the short-circuited rotor conductors and currents create rotor flux. Due to the interaction of stator & rotor flux, a mechanical force (or torque) is developed on the rotor and so the rotor starts moving in the same direction as that of rotating magnetic field.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

38

Control Systems Laboratory Manual / II EEE, IV SEM

GENERAL SCHEMATIC OF AC SERVOMOTOR:

FORMULAE USED: Transfer function, Gm (s) = Km / (1+ sm) Where Motor gain constant, Km = K / FO + F K is T / C FO is T / N Torque, T is 9.81 X R (S1 S2) R is radius of the rotor in m Frictional co-efficient, F = W / (2N / 60)2 Frictional loss, W is 30 % of constant loss in Watts Constant loss in watts = No load input Copper loss No load i/p = V (IR+IC) V is supply voltage, V IR is current through reference winding, A IC is current through control winding, A Copper loss in watts = IC2 RC RC = 174 N is rated speed in rpm Motor time constant, m = J / FO + F Moment of inertia J is d4 L R / 32 d is diameter of the rotor in m ( Given d =39.5 mm) LR is length of the rotor in m (Given L R =76 mm) is density = 7.8 X 102 gm / m

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

39

Control Systems Laboratory Manual / II EEE, IV SEM

PROCEDURE: 1. 1. 2. 3. 4. 5. 6. DETERMINATION OF FRICTIONAL CO-EFFICIENT, F Check whether the MCB is in OFF position. Patch the circuit using the patching diagram. Switch ON the MCB Vary the control pot to apply rated supply voltage Note the control winding current, reference winding current, supply voltage and speed. Find the frictional co-efficient using the above values

OBSERVATIONS: Supply Voltage V (V) Control winding Current Ic (A) Reference Winding Current Ir (A) Speed N (rpm)

S. No.

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

40

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF AC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE FRICTIONAL CO-EFFICIENT F:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

41

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 2. To determine the motor gain constant Km
DETERMINATION OF FO FROM TORQUE - SPEED CHARACTERISTICS:

1. 2. 3. 4. 5. 6.

Check whether the MCB is in OFF position. Patch the circuit using the patching diagram. Set the control pot in minimum position. Check whether the motor is in no load condition Switch ON the MCB Vary the control pot and apply rated voltage to the reference phase winding and control phase winding. Note down the no load speed. 7. Apply load in steps. For each load applied note down the speed and spring balance readings. ( Take 3 or 4 sets of readings) 8. Reduce the load fully and allow the motor to run at rated speed. 9. Repeat steps 7 and 8 for 75 % control winding voltage. 10. Draw the graph between speed and torque, the slope of the graph gives FO. OBSERVATIONS: Control voltage Vc1 = Spring Balance Speed Torque values N T S1 S2 (Nm) (rpm) (kg) (kg) Control voltage Vc2 = Spring Balance Torque Speed values T N S1 S2 (rpm) (Nm) (kg) (kg)

S. No

MODEL GRAPH: TORQUE - SPEED CHARACTERISTICS

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

42

Control Systems Laboratory Manual / II EEE, IV SEM

DETERMINATION OF K FROM TORQUE - CONTROL VOLTAGE CHARACTERISTICS: 1. Check whether the MCB is in OFF position. 2. Patch the circuit using the patching diagram. 3. Set the control pot in minimum position. 4. Check whether the motor is in no load condition 5. Switch ON the MCB 6. Vary the control pot and apply rated voltage to the reference phase winding and control phase winding. Note down the no load speed. 7. Load the motor gradually; the speed of the motor will decrease. Vary the control pot and increase the control winding voltage till the speed obtained at no load is reached. Note down control voltage and spring balance readings. 8. Repeat step 7 for various speeds and tabulate. (for 1000 rpm) 9. Plot the graph between torque and control winding voltage. The slope of the graph gives the value of K. OBSERVATIONS: Control Voltage Vc (V) Speed N1 = Spring Balance values S1 S2 (kg kg Torque T Nm Speed rpm Speed N2 = Spring Balance values S1 S2 Kg Kg Control Voltage Vc V

S. No

MODEL GRAPH: TORQUE - CONTROL VOLTAGE CHARACTERISTICS

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

43

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

44

Control Systems Laboratory Manual / II EEE, IV SEM DETERMINATION OF TRANSFER FUNCTION OF AC SERVO MOTOR PATCHING DIAGRAM TO DETERMINE MOTOR GAIN CONSTANT KM:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

45

Control Systems Laboratory Manual / II EEE, IV SEM CALCULATIONS:

RESULT: The transfer function of AC servomotor is determined as

VIVA-VOCE QUESTIONS: 1. What are the main parts of an AC servomotor? 2. State the advantages and disadvantages of an AC servo motor. 3. Give the applications of AC servomotor. 4. What do you mean by servo mechanism? 5. What are the characteristics of an AC servomotor?

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

46

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No: DETERMINATION OF TRANSFER FUNCTION OF SEPARATELY EXCITED DC GENERATOR AIM: To obtain the transfer function of separately excited DC generator on no load and loaded condition. APPARATUS / INSTRUMENTS REQUIRED: S. No Description Range Type Quantity Date:

THEORY: Derivation of transfer function of separately excited DC generator is as follows, Applying KVL to the field side, ef = Rf if + Lf (dif / dt) Applying KVL to the armature side, eg = Ra ia + La (dia / dt) + RL ia VL = RL ia Also since eg if , let eg = Kg if Taking Laplace transform of equation (1) we get Ef (s) = Rf If(s) + sLf If(s) Ef (s) = If (s) [Rf + sLf] If (s) = Ef (s) / [Rf + sLf] (5) (4) (2) (3) (1)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

47

Control Systems Laboratory Manual / II EEE, IV SEM

Taking Laplace transform of equation (2) we get Eg (s) = Ra Ia(s) + sLa Ia(s) + RL Ia(s) Eg (s) = Ia(s) [Ra + sLa + RL] Taking Laplace transform of equations (3) and (4) we get VL(s) = RL Ia( s) Therefore, Ia( s) = VL(s) / RL Eg(s) = Kg If(s) Substituting. equations (7) and (8) in equation (6) we get Kg If(s) = [Ra + sLa + RL] [VL(s) / RL] Substituting the value of If (s) in the above equation we get Kg Ef (s) / [Rf + sLf] = [Ra + sLa + RL] [ VL(s) / RL] Hence transfer function, VL(s) / Ef (s) = Kg RL / {[Rf + sLf] [Ra + sLa + RL]} For unloaded condition, Ia = 0 Therefore transfer function VL(s) / Ef (s) = Kg / [Rf + sLf] For loaded condition Lf = (Zf2 Rf2) / 2f La = (Za2 Ra2) / 2f Transfer function VL(s) / Ef (s) = Kg RL / [Rf (Ra + RL) (1+sf) (1 + sa)] where f = Lf / Rf and a = La / (Ra + RL) FORMULAE USED: Transfer function of DC generator, On no load condition: VL(s) / Ef (s) = Kg / [Rf + sLf] where Kg is gain constant Rf is field resistance in Ohms Lf is field inductance in Henry On loaded condition: VL(s) / Ef (s) = Kg RL / [Rf (Ra + RL) (1+sf) (1 + sa)] where Kg is gain constant Field time constant f = Lf / Rf Rf is field resistance in Ohms Lf is field inductance in Henry Armature time constant a = La / (Ra + RL) Ra is armature resistance in Ohms La is armature inductance in Henry Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

(6)

(7) (8) (9)

(10) (11)

(12)

48

Control Systems Laboratory Manual / II EEE, IV SEM

PROCEDURE: 1. To determine the gain constant Kg : No load or open circuit characteristics: 1. Connections are made as shown in the circuit diagram 2. The motor field rheostat should be in minimum resistance position and the generator field rheostat should be in maximum resistance position or minimum potential position while switching ON and switching OFF the supply side DPST switch. 3. Ensure that the DPST switch on the load side is open. 4. Switch ON the supply DPST switch. 5. Using the 3- point starter the DC motor is started and it is brought to rated speed by adjusting the motor field rheostat. 6. Keeping the DPST switch on the load side open, the generated voltage Eg and field current If of generator is noted down by varying the generator field rheostat. 7. The above step is repeated till 125 % of rated voltage is reached. 8. A graph is plotted between Eg and If taking If along x- axis. A tangent to the linear portion of the curve is drawn from the origin and slope of this line gives Kg. OBSERVATIONS: S. No. Field current, If (A) Induced Voltage, Eg (V)

MODEL GRAPH:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

49

Control Systems Laboratory Manual / II EEE, IV SEM

CIRCUIT DIAGRAM: To determine gain constant, Kg:

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

50

Control Systems Laboratory Manual / II EEE, IV SEM

Load characteristics: 1. Connections are made as shown in the circuit diagram 2. The motor field rheostat should be in minimum resistance position and the generator field rheostat should be in maximum resistance position or minimum potential position while switching ON and switching OFF the supply side DPST switch. 3. Ensure that the DPST switch on the load side is open. 4. Switch ON the supply DPST switch 5. The generator is brought to its rated voltage by varying the generator field rheostat. 6. The DPST switch on the load side is closed, and the load is varied for convenient steps of load current up to 120 % of its rated capacity and the voltmeter VL and ammeter Ia readings are observed. On each loading the speed should be maintained at rated speed. 7. A graph is plotted between VL and IL taking IL on x- axis. The slope of the graph gives Kg. OBSERVATIONS: S. No. Terminal Voltage, VL (V) Load Current, IL (A)

MODEL GRAPH:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

51

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 2. To determine field Inductance Lf : 1. Connections are made as per the circuit diagram. 2. Auto transformer is varied in steps for different voltages and corresponding voltmeter and ammeter readings are noted down. 3. Field impedance Zf is calculated as V/I and the average value of Zf is obtained. 4. Field resistance (Rf) is measured using multimeter. 5. Field inductance (Lf) can be calculated using formula Lf = (Zf2 Rf2) / 2f CIRCUIT DIAGRAM:

OBSERVATIONS: S. No Field Voltage, V (V) Field Current, I (A) Field Impedence, Zf (Ohms)

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

52

Control Systems Laboratory Manual / II EEE, IV SEM PROCEDURE: 3. Determination of armature inductance La : 1. Connections are made as per the circuit diagram. 2. Auto transformer is varied in steps for different voltages and corresponding voltmeter and ammeter readings are noted down. 3. Armature impedance Za is calculated as V/I and the average value of Za is obtained. 4. Armature resistance Ra is measured using multimeter. 5. Armature inductance La can be calculated using formula, La = (Za2 Ra2) / 2f CIRCUIT DIAGRAM:

OBSERVATIONS: S. No Armature Voltage, V (V) Armature Current, I (A) Armature Impedence, Za (Ohms)

CALCULATIONS:

CALCULATIONS: Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

53

Control Systems Laboratory Manual / II EEE, IV SEM

RESULT: The transfer function of separately excited DC generator is determined as

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

54

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No: Date: DETERMINATION OF TRANSFER FUNCTION OF DC MOTOR AIM: To obtain the transfer function of field controlled DC motor. APPARATUS / INSTRUMENTS REQUIRED: S. No Description Range Type Quantity

THEORY:

FIELD CONTROLLED MOTOR:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

55

Control Systems Laboratory Manual / II EEE, IV SEM

FORMULAE USED: Transfer function of field controlled DC motor, (s) / Vf (s) = Km / [s (1+sf) (1 + sm)] where Motor gain constant, Km = Ktf / (BRf) Ktf is motor torque constant Torque, T is 9.81 X R (S1 S2) R is radius of the brake drum in m R = circumference of the brake drum/ (2 ) B is viscous co-efficient of friction Rf is field resistance in Ohms Field time constant f = Lf / Rf Rf is field resistance in Ohms Lf is field inductance in Henry Lf = (Zf2 Rf2) / 2f Zf is field impedence in Ohms Rf is field resistance in Ohms Mechanical time constant m = J/B Moment of inertia J = Pav / [22(N12 N22 )((1/t1)-(1/t2))] Average power delivered to the load, Pav= (V1I1 + I12 Ra + V2I2 + I22 Ra) / 2 Ra is armature resistance in Ohms La is armature inductance in Henry t2 is time taken on load in secs t1 is time taken on no load in secs Viscous Co-efficient of friction, B = Pstray / (N1 + N2)2 Stray loss, Pstray = [22(N12 N22 )] J / t1 PROCEDURE:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

56

Control Systems Laboratory Manual / II EEE, IV SEM 1. To determine motor torque constant, Ktf : 1. Connections are made as shown in the circuit diagram 2. The armature current Ia of the motor is set to some value by adjusting the armature circuit resistance. This value of Ia is maintained constant throughout the experiment. 3. The field current If is varied in steps by adjusting the field rheostat and for each value of If the brake drum is adjusted such that it just fails to rotate. The corresponding readings of ammeter and spring balances are noted. 4. The value of torque for each value of If is calculated 5. A graph is plotted between torque T and field current IF taking IF along x-axis. The slope of the graph gives the value of Ktf OBSERVATIONS: S. No. Armature current Ia (A) Field current If (A) Spring balance readings S1 S2 (kg) (kg) Torque T (Nm)

MODEL GRAPH:

CIRCUIT DIAGRAM: Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

57

Control Systems Laboratory Manual / II EEE, IV SEM

CALCULATIONS:

PROCEDURE 2. To determine field Inductance Lf : Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

58

Control Systems Laboratory Manual / II EEE, IV SEM

1. Connections are made as per the circuit diagram. 2. Auto transformer is varied in steps for different voltages and corresponding voltmeter and ammeter readings are noted down. 3. Field impedance Zf is calculated as V/I and the average value of Zf is obtained. 4. Field resistance (Rf) is measured using multimeter. 5. Field inductance (Lf) can be calculated using formula Lf = (Zf2 Rf2) / 2f CIRCUIT DIAGRAM:

OBSERVATIONS: S. No. Field Voltage, V (V) Field Current, I (A) Field Impedence, Zf ()

CALCULATIONS:

PROCEDURE:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

59

Control Systems Laboratory Manual / II EEE, IV SEM 3. To determine moment of inertia J and Viscous friction Co-efficient B: 1. Connections are made as shown in the circuit diagram 2. The field current of the motor is set to some value by adjusting the field resistance. 3. DPDT switch is thrown to position (1,11) and the motor is made to run at a speed N1 (1700 rpm) by adjusting the armature rheostat. 4. DPDT switch is opened from position (1,11) and the stop watch is started simultaneously. The time taken t1 for the speed to drop from N1(1700 rpm) to N2 ( 1300 rpm) is noted. 5. Again the DPDT switch is thrown to position (1,11) and the motor is made to run at a speed greater than N1 (1700 rpm) by adjusting the armature rheostat. 6. DPDT switch is thrown to position (2,21) and the stop watch is started when the motor speed reaches N1 (1700 rpm). The time taken t2 for the speed to drop from N1 (1700 rpm) to N2( 1300 rpm) is noted. Simultaneously the readings of the ammeter and voltmeter corresponding to N1 and N2 are noted. OBSERVATIONS: S. No. N1 (rpm) t1 (Sec) V1 (V) I1 (A) N2 (rpm) T2 (Sec) V2 (V) I2 (A)

CALCULATIONS:

CIRCUIT DIAGRAM:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

60

Control Systems Laboratory Manual / II EEE, IV SEM

CALCULATIONS:

CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

61

Control Systems Laboratory Manual / II EEE, IV SEM

RESULT: The transfer function of field controlled DC motor is determined as

Expt. No: DC POSITION CONTROL SYSTEM

Date:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

62

Control Systems Laboratory Manual / II EEE, IV SEM

AIM: To study the characteristics of a DC position control system. APPARATUS / INSTRUMENTS REQUIRED:
i)

DC position control kit and Motor unit Multimeter

THEORY: A DC position control system is a closed loop control system in which the position of the mechanical load is controlled with the position of the reference shaft. A pair of potentiometers acts as error-measuring device. They convert the input and output positions into proportional electric signals. The desired position is set on the input potentiometer and the actual position is fed to feedback potentiometer. The difference between the two angular positions generates an error signal, which is amplified and fed to armature circuit of the DC motor. The tachogenerator attached to the motor shaft produces a voltage proportional to the speed which is used for feedback. If an error exists, the motor develops a torque to rotate the output in such a way as to reduce the error to zero. The rotation of the motor stops when the error signal is zero, i.e., when the desired position is reached. PROCEDURE: 1. The input or reference potentiometer is adjusted nearer to zero initially( R). 2. The command switch is kept in continuous mode and some value of forward gain K A is selected. 3. For various positions of input potentiometer ( R) the positions of the response potentiometer ( 0) is noted. Simultaneously the reference voltage (VR) measured between the terminals VR & E and the output voltage (VO) measured between the terminals VO & E are noted. 4. A graph is plotted with 0 along y-axis and R along x-axis.

OBSERVATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

63

Control Systems Laboratory Manual / II EEE, IV SEM Reference angular position, R (degrees) KA = KA = Output angular position, O (degrees) KA = KA = Reference Voltage, Vr (V) KA = KA = Output VoltageVO (V) KA = KA =

S. No

MODEL GRAPH:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

64

Control Systems Laboratory Manual / II EEE, IV SEM

DC POSITION CONTROL SYSTEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

65

Control Systems Laboratory Manual / II EEE, IV SEM

RESULT: The DC position control system characteristics are studied and corresponding graphs are drawn.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

66

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No. Date: ANALOG SIMULATION OF TYPE 0 and TYPE 1 SYSTEMS AIM: To study the time response of first and second order type 0 and type- 1 systems. APPARATUS / INSTRUMENTS REQUIRED: 1. Linear system simulator kit 2. CRO 3. Patch cords FORMULAE USED: Damping ratio, = (ln MP)2 / (2 +(ln MP)2) Where MP is peak percent overshoot obtained from the time response graph Undamped natural frequency, n = / [tp (1 - 2)] where tp is the peak time obtained from the time response graph Closed loop transfer function of the type 0 second order system is C(s)/R(s) = G(s) / [1 + G(s) H(s)] where H(s) = 1 G(s) = K K2 K3 / (1+sT1) (1 + sT2) where K is the gain K2 is the gain of the time constant 1 block =10 K3 is the gain of the time constant 2 block =10 T1 is the time constant of time constant 1 block = 1 ms T2 is the time constant of time constant 2 block = 1 ms Closed loop transfer function of the type 1-second order system is C(s)/R(s) = G(s) / [1 + G(s) H(s)] where H(s) = 1 G(s) = K K1 K2 / s (1 + sT1) where K is the gain K1 is the gain of Integrator = 9.6 K2 is the gain of the time constant 1 block =10 T1 is the time constant of time constant 1 block = 1 ms THEORY: The type number of the system is obtained from the number of poles located at origin in a given system. Type 0 system means there is no pole at origin. Type 1 system means there is one pole located at the origin. The order of the system is obtained from the highest power of s in the denominator of closed loop transfer function of the system. The first order system is characterized Prepared by V.Arivumani, AP/EEE, Vels University, Chennai 67

Control Systems Laboratory Manual / II EEE, IV SEM by one pole or a zero. Examples of first order systems are a pure integrator and a single time constant having transfer function of the form K/s and K/(sT+1). The second order system is characterized by two poles and up to two zeros. The standard form of a second order system is G(s) = n2 / (s2 + 2ns + n2) where is damping ratio and n is undamped natural frequency. PROCEDURE: 1. To find the steady state error of type 0 first order system 1. Connections are made in the simulator kit as shown in the block diagram. 2. The input square wave is set to 2 Vpp in the CRO and this is applied to the REF terminal of error detector block. The input is also connected to the X- channel of CRO. 3. The output from the simulator kit is connected to the Y- channel of CRO. 4. The CRO is kept in X-Y mode and the steady state error is obtained as the vertical displacement between the two curves. 5. The gain K is varied and different values of steady state errors are noted. Block diagram of Type-0 first order system

OBSERVATIONS: S. No. 1 2 3 Gain, K Steady state error, ess

TRACES FROM CRO: Prepared by V.Arivumani, AP/EEE, Vels University, Chennai 68

Control Systems Laboratory Manual / II EEE, IV SEM For Gain, K =

For Gain, K =

For Gain, K=

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

69

Control Systems Laboratory Manual / II EEE, IV SEM

LINEAR SYSTEM SIMULATOR PATCHING DIAGRAM TO OBTAIN THE STEADY STATE ERROR OF TYPE 0 FIRST ORDER SYSTEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

70

Control Systems Laboratory Manual / II EEE, IV SEM

2. To find the steady state error of type 1 first order system 1. The blocks are Connected using the patch chords in the simulator kit. 2. The input triangular wave is set to 2 Vpp in the CRO and this applied o the REF terminal of error detector block. The input is also connected to the X- channel of CRO. 3. The output from the system is connected to the Y- channel of CRO. 4. The experiment should be conducted at the lowest frequency to allow enough time for the step response to reach near steady state. 5. The CRO is kept in X-Y mode and the steady state error is obtained as the vertical displacement between the two curves. 6. The gain K is varied and different values of steady state errors are noted. 7. The steady state error is also calculated theoretically and the two values are compared. Block diagram of Type- 1 First order system

OBSERVATIONS: S. No. 1 2 3 Gain, K Steady state error, ess

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

71

Control Systems Laboratory Manual / II EEE, IV SEM

TRACES FROM CRO: For Gain, K =

For Gain, K =

For Gain, K =

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

72

Control Systems Laboratory Manual / II EEE, IV SEM

LINEAR SYSTEM SIMULATOR PATCHING DIAGRAM TO OBTAIN THE STEADY STATE ERROR OF TYPE 1 FIRST ORDER SYSTEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

73

Control Systems Laboratory Manual / II EEE, IV SEM 3. To find the closed loop response of type 0 and type- 1 second order system 1. The blocks are connected using the patch chords in the simulator kit. 2. The input square wave is set to 2 Vpp in the CRO and this applied to the REF terminal of error detector block. The input is also connected to the X- channel of CRO. 3. The output from the system is connected to the Y- channel of CRO. 4. The output waveform is obtained in the CRO and it is traced on a graph sheet. From the waveform the peak percent overshoot, settling time,rise time, peak time are measured. Using these values n and are calculated. 5. The above procedure is repeated for different values of gain K and the values are compared with the theoretical values. Block diagram to obtain closed loop response of Type-0 second order system

OBSERVATIONS: Peak percent Overshoot %MP 1 2 Rise time tr (sec) Peak Time tp (sec) Settling time ts (sec) Undamped Natural frequency n (rad/sec)

S. No.

Gain K

Damping ratio

TRACES FROM CRO: For Gain, K = For Gain, K =

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

74

Control Systems Laboratory Manual / II EEE, IV SEM Block diagram to obtain closed loop response of Type-1 second order system

OBSERVATIONS: Peak percent Overshoot %MP 1 2 Rise time tr (sec) Peak Time tp (sec) Settling time ts (sec) Undamped Natural frequency n (rad/sec)

S. No.

Gain K

Damping ratio

TRACES FROM CRO: For Gain, K = For Gain, K =

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

75

Control Systems Laboratory Manual / II EEE, IV SEM

LINEAR SYSTEM SIMULATOR PATCHING DIAGRAM TO OBTAIN THE CLOSED LOOP RESPONSE OF TYPE 0 SECOND ORDER SYSTEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

76

Control Systems Laboratory Manual / II EEE, IV SEM

LINEAR SYSTEM SIMULATOR PATCHING DIAGRAM TO OBTAIN THE CLOSED LOOP RESPONSE OF TYPE 1 SECOND ORDER SYSTEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

77

Control Systems Laboratory Manual / II EEE, IV SEM CALCULATIONS:

RESULT: The time response of first and second order type-0 and type-1 systems are studied.

VIVA-VOCE QUESTIONS: 1. 2. 3. 4. 5. 6. Define order and type number. What are dominant poles? What is a closed loop system? What is the effect of negative feedback? What are poles and zeros of a system? Define transfer function.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

78

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No. AIM: To digitally simulate the time response characteristics of a linear system without non- linearities and to verify it manually. APPARATUS REQUIRED: A PC with MATLAB package THEORY: The time response characteristics of control systems are specified in terms of time domain specifications. Systems with energy storage elements cannot respond instantaneously and will exhibit transient responses, whenever they are subjected to inputs or disturbances. The desired performance characteristics of a system of any order may be specified in terms of transient response to a unit step input signal. The transient response characteristics of a control system to a unit step input is specified in terms of the following time domain specifications Delay time td Rise time tr Peak time tp Maximum peak overshoot Mp Settling time ts STUDY OF BASIC MATLAB COMMANDS: The name MATLAB stands for MATRIX LABORATORY. MATLAB was originally written to provide easy access to matrix software developed by the LINPACK and EISPACK projects. Today, MATLAB engines incorporate the LAPACK and BLAS libraries, embedding the state of the art in software for matrix computation. It has evolved over a period of years with input from many users. In university environments, it is the standard instructional tool for introductory and advanced courses in MATHEMATICS, ENGINEERING, AND SCIENCE. In industry, MATLAB is the tool of choice for high-productivity research, development, and analysis. MATLAB is a high-performance language for technical computing. It integrates computation, visualization, and programming in an easy-to-use environment where problems and solutions are expressed in familiar mathematical notation. Typical uses include, Math and computation Algorithm development Data acquisition Modeling, simulation, and prototyping Data analysis, exploration, and visualization Scientific and engineering graphics 79 Date: DIGITAL SIMULATION OF FIRST ORDER SYSTEMS

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

Control Systems Laboratory Manual / II EEE, IV SEM Application development, including graphical user interface building

It is an interactive system whose basic data element is an array that does not require dimensioning. This allows you to solve many technical computing problems, especially those with matrix and vector formulations, in a fraction of the time it would take to write a program in a scalar non-interactive language such as C or Fortran. It also features a family of add-on application-specific solutions called toolboxes. Very important to most users of MATLAB, toolboxes allow you to learn and apply specialized technology. Toolboxes are comprehensive collections of MATLAB functions (M-files) that extend the MATLAB environment to solve particular classes of problems. Areas in which toolboxes are available include SIGNAL PROCESSING, CONTROL SYSTEMS, NEURAL NETWORKS, FUZZY LOGIC, WAVELETS, SIMULATION, AND MANY OTHERS. Some practical examples of first order systems are RL and RC circuits. PROCEDURE: 1. Derive the transfer function of a RL series circuit. 2. Assume R= 1 Ohms L = 0. 1 H. Find the step response theoretically and plot it on a graph sheet. 3. To build a SIMULINK model to obtain step response / sine response of a first order system, the following procedure is followed: 1. In MATLAB software open a new model in SIMULINK library browser. 2. From the continuous block in the library drag the transfer function block. 3. From the source block in the library drag the step input/ sine input. 4. From the sink block in the library drag the scope. 5. From the math operations block in the library drag the summing point. 6. Connect all to form a system and give unity feedback to the system. 7. For changing the parameters of the blocks connected double click the respective block. 8. Start simulation and observe the results in scope. (Use a mux from the signal routing block to view more than one graph in the scope) 9. Compare the simulated and theoretical results. BLOCK DIAGRAM: Step response of a first order system:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

80

Control Systems Laboratory Manual / II EEE, IV SEM

Sine response of a first order system:

2. MATLAB (m-file) program to obtain the step response and impulse response % MATLAB program to find the step response num=[ ]; den=[ ]; sys = tf (num,den); step (sys); grid OUTPUT: (Paste the graph obtained from PC)

% MATLAB program to find the impulse response num=[ ]; den=[ ]; sys = tf (num,den); impulse (sys); grid

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

81

Control Systems Laboratory Manual / II EEE, IV SEM OUTPUT: (Paste the graph obtained from PC)

CALCULATIONS: Unit step response of the given RL series circuit:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

82

Control Systems Laboratory Manual / II EEE, IV SEM

Unit Impulse response of the given RLC series circuit:

RESULT: The time response characteristics of a first order system is simulated digitally and verified manually. VIVA-VOCE QUESTIONS: 1. 2. 3. 4. 5. 6. 7. 8. What is MATLAB? What is the use of MATLAB Package? What are the toolboxes available in MATLAB? What is the use of a simulation? Differentiate real time systems and simulated systems. Give two examples for first order system. Name the standard test signals used in control system. What is time response?

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

83

Control Systems Laboratory Manual / II EEE, IV SEM

Expt. No: DIGITAL SIMULATION OF SECOND ORDER SYSTEMS AIM:

Date:

To digitally simulate the time response characteristics of a second order system and verify manually. APPARATUS REQUIRED A PC with MATLAB Software THEORY The time characteristics of control systems are specified in terms of time domain specifications. Systems with energy storage elements cannot respond instantaneously and will exhibit transient responses, whenever they are subjected to inputs or disturbances. The desired performance characteristics of a system of any order may be specified in terms of transient response to a unit step input signal. The transient response characteristics of a control system to a unit step input is specified in terms of the following time domain specifications: Delay time td Rise time tr Peak time tp Maximum overshoot Mp Settling time ts PROCEDURE: 1. Derive the transfer function of a RLC series circuit. 2. Assume R= 1 Ohms, L = 0. 1 H and C = 1 micro Farad. Find the step response theoretically and plot it on a graph sheet. 3. To build a SIMULINK model to obtain step response / sine response of a second order system, the following procedure is followed: 1. In MATLAB software open a new model in SIMULINK library browser. 2. From the continuous block in the library drag the transfer function block. 3. From the source block in the library drag the step input/ sine input. 4. From the sink block in the library drag the scope. 5. From the math operations block in the library drag the summing point. 6. Connect all to form a system and give unity feedback to the system. 7. For changing the parameters of the blocks connected double click the respective block. 8. Start simulation and observe the results in scope. (Use a mux from the signal routing block to view more than one graph in the scope) 9. From the step response obtained note down the rise time, peak time, peak overshoot and settling time. 10. Compare the simulated and theoretical results. Prepared by V.Arivumani, AP/EEE, Vels University, Chennai 84

Control Systems Laboratory Manual / II EEE, IV SEM

BLOCK DIAGRAM: Step response of a second order system:

Sine response of a second order system:

2. MATLAB program to obtain the step response and impulse response of second order system. % MATLAB program to find the step response num=[ ]; den=[ ]; sys = tf (num,den); step (sys); OUTPUT: (Paste the graph obtained from PC)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

85

Control Systems Laboratory Manual / II EEE, IV SEM

% MATLAB program to find the impulse response num=[ ]; den=[ ]; sys = tf (num,den); impulse (sys); OUTPUT: (Paste the graph obtained from PC)

CALCULATIONS: Unit step response of the given RLC series circuit:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

86

Control Systems Laboratory Manual / II EEE, IV SEM

Unit impulse response of the given RLC series circuit:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

87

Control Systems Laboratory Manual / II EEE, IV SEM

RESULT: The time response characteristics of the given second order system is simulated digitally and verified manually. VIVA-VOCE QUESTIONS: 1. 2. 3. 4. 5. 6. 7. 8. What is MATLAB? What is the use of MATLAB Package? What are the toolboxes available in MATLAB? What is the use of a simulation? Differentiate real time systems and simulated systems. Give two examples for second order system. Name the standard test signals used in control system. What is time response?

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

88

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No: STABILITY ANALYSIS OF LINEAR SYSTEMS a. USING BODE PLOT
AIM:

Date:

To obtain the bode plot and check for stability of the system with open loop transfer function, G(S) = APPARATUS REQUIRED: A PC with MATLAB Software THEORY: A Linear Time-Invariant Systems is stable if the following two notions of system stability are satisfied When the system is excited by Bounded input, the output is also a Bounded output. In the absence of the input, the output tends towards zero, irrespective of the initial conditions. The following observations are general considerations regarding system stability, If all the roots of the characteristic equation have negative real parts, then the impulse response is bounded and eventually decreases to zero, then system is stable. If any root of the characteristic equation has a positive real part, then system is unstable. If the characteristic equation has repeated roots on the j-axis, then system is unstable. If one are more non-repeated roots of the characteristic equation on the j-axis, then system is unstable. BODE PLOT : Consider a Single-Input Single-Output system with transfer function C(s) = R(s) Where m < n. a0 sn + a1sn-1 + +an b0 sm + b1 sm-1 + + bm

Rule 1 A system is stable if the phase lag is less than 180 at the frequency for which the gain is unity (one). Prepared by V.Arivumani, AP/EEE, Vels University, Chennai 89

Control Systems Laboratory Manual / II EEE, IV SEM Rule 2 A system is stable if the gain is less than one (unity) at the frequency for which the phase lag is 180. The application of these rules to an actual process requires evaluation of the gain and phase shift of the system for all frequencies to see if rules 1 and 2 are satisfied. This is obtained by plotting the gain and phase versus frequency. This plot is called BODE PLOT. The gain obtained here is open loop gain. The exact terminology is in terms of a Gain Margin and Phase Margin from the limiting values quoted. If the phase lag is less than 140 at the unity gain frequency, the system is stable. This then, is a 40 Phase Margin from the limiting values of 180. If the gain is 5dB below unity (or a gain of about 0.56) when the phase lag is 180, the system is stable. This is 5dB Gain Margin.

PROCEDURE: Step 1: Write a program to obtain the Bode plot for the given system. Step 2: Assess the stability of given system using the plot obtained. PROGRAM %BODE PLOT OF THE SYSTEM %Enter the numerator and denominator of the transfer function num=[ den=[ sys=tf(num,den) %Specify the frequency range and enter the command w=logspace(-2,4,1000); bode(sys,w) xlabel('Frequency') ylabel( ' Phase angle in degrees Magnitude of G(s) in decibels') title('Bode Plot of the system %Phase cross over frequency margin(sys) [ Gm, Pm, Wpc, Wgc ]= margin (sys) ') %To determine the Gain Margin, Phase Margin, Gain crossover frequency and ]; ];

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

90

Control Systems Laboratory Manual / II EEE, IV SEM

MANUAL CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

91

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

92

Control Systems Laboratory Manual / II EEE, IV SEM

OUTPUT (from manual calculation):

OUTPUT (from program):

RESULT: The Bode plot is drawn for the given transfer function using MATLAB and verified manually. From the plot obtained, the system is found to be ______________. VIVA-VOCE QUESTIONS: 1. 2. 3. 4.
5.

6. 7. 8. 9.

Define stability of Linear Time Invariant System. Give the stability conditions of system using Pole-Zero plot. Define Bode Plot. What is the use of Bode Plot? What the conditions of stability are in Bode plot? Define Stability criteria. Define Limits of stability. Define safe regions in stability criteria. Define Phase margin and Gain margin.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

93

Control Systems Laboratory Manual / II EEE, IV SEM b. Using Root Locus AIM: To obtain the Root locus plot and to verify the stability of the system with transfer function, G(s) = APPARATUS REQUIRED: A PC with MATLAB Software THEORY: ROOT LOCUS PLOT: The characteristic of the transient response of a closed-loop system is related to the location of the closed loop poles. If the system has a variable loop gain, then the location of the closedloop poles depend on the value of the loop gain chosen. A simple technique known as Root Locus Technique used for studying linear control systems in the investigation of the trajectories of the roots of the characteristic equation. This technique provides a graphical method of plotting the locus of the roots in the s-plane as a given system parameter is varied over the complete range of values (may be from zero to infinity). The roots corresponding to a particular value of the system parameter can then be located on the locus or the value of the parameter for a desired root location can be determined form the locus. The root locus is a powerful technique as it brings into focus the complete dynamic response of the system. The root locus also provides a measure of sensitivity of roots to the variation in the parameter being considered. This technique is applicable to both single as well as multiple-loop systems. PROCEDURE: 1. Write a program to obtain the root locus plot for the given system. 2. Assess the stability of given system using the plot obtained. PROGRAM: %ROOT LOCUS OF THE SYSTEM% num=[ den=[ sys=tf(num,den) rlocus(sys) v=[-10,10,-8,8]; axis(v) Prepared by V.Arivumani, AP/EEE, Vels University, Chennai 94 ] ]

Control Systems Laboratory Manual / II EEE, IV SEM xlabel('Real Axis') ylabel('Imaginary Axis') title('Root Locus of the system') title('Root Locus Plot of the system MANUAL CALCULATIONS: ')

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

95

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

96

Control Systems Laboratory Manual / II EEE, IV SEM OUTPUT (from manual calculation)

OUTPUT (from program):

RESULT: The Root locus plot is drawn for the given transfer function, G(s)= ___________________ using MATLAB and the range of gain K for stability is______________. VIVA-VOCE QUESTIONS: 1. Define root locus technique. 2. What are the conditions of stability in root locus criteria? 3. What is the advantage of root locus technique? 4. Which method of stability analysis is more advantageous? 5. How the stability of unstable is improved? 6. What are the methods to improve the stability? 7. What is the use of compensators? 8. What do you mean by Root-Loci? 9. What is complementary Root Loci? 10. What are contours? 11. State the basic properties of Root Locus. 12. How would you find the number of branches of Root Loci? 13. How are the break away points of the root locus determined? 14. How is the point of intersection of the asymptotes with real axis found out.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

97

Control Systems Laboratory Manual / II EEE, IV SEM c. USING NYQUIST PLOT AIM: To obtain the Nyquist plot and check the stability of the system using Nyquist Stability Criterion for the given unity feedback system with transfer function G(s)H(s) = APPARATUS REQUIRED A PC with MATLAB Software THEORY: NYQUIST STABILITY CRITERION:

POLAR PLOTS / NYQUIST PLOTS: The sinusoidal transfer function G(j) is a complex function is given by G(j) = Re[ G(j)] + j Im[G(j)] or G(j) = G(j) G(j) = M -----------(1) From equation (1), it is seen that G(j) may be represented as a phasor of magnitude M and phase angle . As the input frequency varies from 0 to , the magnitude M and phase angle changes and hence the tip of the phasor G(j) traces a locus in the complex plane. The locus thus obtained is known as POLAR PLOT. The major advantage of the polar plot lies in stability study of systems. Nyquist related the stability of a system to the form of these plots. Polar plots are referred as NYQUIST PLOTS. PROCEDURE: 1. Write a program to obtain the Nyquist plot for the given system. 2. Assess the stability of given system using the plot obtained.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

98

Control Systems Laboratory Manual / II EEE, IV SEM PROGRAM %NYQUIST PLOT %Enter the numerator and denominator of the transfer function num=[ ] den=[ ] sys=tf(num,den) %Specify the frequency range and enter the command nyquist(sys) v=[ ] axis(v) xlabel('Real Axis'); ylabel('Imaginary Axis'); title('Nyquist Plot of the system MANUAL CALCULATIONS:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

99

Control Systems Laboratory Manual / II EEE, IV SEM

OUTPUT ( from Manual calculation)

OUTPUT (from program)

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

100

Control Systems Laboratory Manual / II EEE, IV SEM RESULT: The Nyquist plot is drawn for the given transfer function, G(s) = ______________________ using MATLAB and the system is found to be ______________________.

VIVA-VOCE QUESTIONS: 1. 2. 3. 4. 5. What is polar plot? What is Nyquist plot? Define the conditions of stability in polar plot. What is the use and advantage of polar plot? State Nyquist stability criterion.

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

101

Control Systems Laboratory Manual / II EEE, IV SEM Expt. No: STEPPER MOTOR CONTROL SYSTEM Date:

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

102

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

103

Control Systems Laboratory Manual / II EEE, IV SEM

Prepared by V.Arivumani, AP/EEE, Vels University, Chennai

104

Das könnte Ihnen auch gefallen