Sie sind auf Seite 1von 53

Emphasis is laid on analog and digital

w w

techniques used to measure voltage, current, energy and power etc.


by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE 1

.e e

ee xc

lu si v

error, calibration etc.

e. bl

og

Introduction to general instrument system,

sp

ot

.c o

EE 2201MEASUREMENTS AND 2201MEASUREMENTS INSTRUMENTATION

To have an adequate knowledge of comparison methods of measurement.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

Exposure to various transducers and data acquisition system.

e. bl

og

sp

Elaborate discussion about storage & display devices.


ot .c o

1.INTRODUCTION
Functional elements of an instrument Static and dynamic characteristics Errors in measurement Statistical evaluation of measurement data Standards and calibration. 9

Principle and types of analog and digital voltmeters, ammeters, multimeters Single and three phase wattmeters and energy meters Magnetic measurements Determination of B-H curve and measurements of iron loss Instrument transformers Instruments for measurement of frequency and phase. 9 by V.BALAJI, M.Tech,(P h.D),

w w

.e e

ee xc

2. ELECTRICAL AND ELECTRONICS INSTRUMENTS

lu si v

e. bl

og

sp

ot

.c o

AP/EEE ,DCE

3.

COMPARISON METHODS OF MEASUREMENTS 9

Magnetic disk and tape Recorders, digital plotters and printers, CRT display, digital CRO, LED, LCD & dot matrix display- Data Loggers.

w w

.e e

4.

STORAGE AND DISPLAY DEVICES

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

D.C & A.C potentiometers, D.C & A.C bridges, transformer ratio bridges, selfbalancing bridges. Interference & screening Multiple earth and earth loops Electrostatic and electromagnetic interference Grounding techniques.

e. bl

og

sp

ot

.c o

TRANSDUCERS AND DATA ACQUISITION SYSTEMS

w w

.e e

ee xc

Classification of transducers Selection of transducers Resistive, capacitive & inductive transducers Piezoelectric, optical and digital transducers Elements of data acquisition system A/D, D/A convertersSmart Sensors.
lu si v e. bl og sp ot .c o m

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

INTRODUCTION
og

sp

ot

.c o

FUNCTIONAL ELEMENTS OF MEASUREMENT SYSTEM Three main functional elements are Primary sensing element Variable conversion element Data presentation element
w w w .e e ee xc lu si v e. bl og sp ot .c o m
by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

BLOCK DIAGRAM OF FUNCTIONAL ELEMENTS OF MEASUREMENT SYSTEM


.c o
Measuring quantity (Measurand)
Primary sensing Element Variable Conversion Element Variable Manipulation Element

m e. bl og
Data storage/ Playback Element

sp

ot

.e e

ee xc

Data Transmission Element

Data Presentation Element

lu si v

w w

To Observer

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

Static And Dynamic Characteristics


Static Characteristics : Static characteristics are those that must be considered when the system or instrument is used to condition not varying with time or vary only quite slowly. Main Static characteristics: i) Accuracy ii) Static error iii) Sensitivity iv) Dead zone V) Reproducibility vi) Drift vii) True value

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

Accuracy: Accuracy is the closeness with which an instrument reading approaches the true value of the quantity being measured.

Sensitivity = change in output signal or measure change in output signal or measure Reproducibility: Reproducibility is the degree of closeness with which a given value may be repeatedly measured. It may be specified in turns of units for a given period of time. Drift : Drift means that with given input the measured value do not vary with time. It is undesirable in instruments because it is rarely apparent by V.BALAJI, M.Tech,(P h.D), and cannot be easily compensated.AP/EEE ,DCE

w w

.e e

ee xc

lu si v

e. bl

og

Sensitivity means the ability to feel or realize readily an accurately the slight changes in the input quantity.

sp

ot

.c o

Sensitivity:

10

DRIFT CLASSSIFICATION

Characteristics with zero drift

Input

w w

.e e

Output

ee xc

Nominal characteristics

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

1.

Zero drift: If entire calibration shifts due to slippage permanent or due to undue warming up of electronic tube circuits ,zero drift occurs as shown in fig 1.1.
m

11

DRIFT CLASSSIFICATION

Input

w w

.e e

Output

ee xc

Nominal characteristics

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

Characteristics with Span drift

e. bl

og

sp

ot

.c o

2.

Span (or) Sensitivity drift: If there is proportional change in the indication all along the upward scale, the drift is called span or sensitivity drift as shown in fig 1.

12

DRIFT CLASSSIFICATION

Input

w w

.e e

Output

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

Characteristics with zero drift

Repeatability

e. bl

og

sp

ot

.c o

3.

Zonal drift: If the drift occurs only over a portion of span over a portion of instrument, it is called as zonal drift as shown in fig 1.3.

13

Precision: Precision is measure of the reproducibility of the measurements, i.e. given a fixed value of a quantity; it is a measure of the degree of agreement within a group of measurements.

static error = Am Ar Am = Measured value of quantity A r = true value of quantity by V.BALAJI, M.Tech,(P h.D),
AP/EEE ,DCE 14

w w

Static error is defined as the difference between the measured value and true value of the quantity.

.e e

Static error:

ee xc

True value of a quantity to be measured is defined as the average of an infinite number of measured values when the average deviation to the various contributing factors tends to zero.

lu si v

e. bl

og

True value:

sp

ot

.c o

Dead zone: Dead zone is defined as the largest change of input quantity for which there is no output for the system.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

Repeatability is defined as the variation of scale reading and is random in nature.

ot

.c o

Repeatability:

15

Dynamic characteristics
Dynamic characteristics: The Dynamic characteristics of an instrument refers to performance of instrument when it is subjected to time varying input. The performance criteria based upon the dynamic relation constitute the dynamic characteristics. Some of Dynamic characteristics are Speed of response Measuring lag Fidelity Dynamic error

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

16

1. Speed of response It is defined as the rapidity with which a measurement system responds to changes in the measured quantity.

ii)Time delay type:

w w

In this type response begins after a dead time, after the application of input. Dead time simply shift the response along the time scale and causes a corresponding dynamic error.

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

In this type, the response of an instrument begins immediately after a change in measured quantity has occurred.

e. bl

i) Retardation type:

og

sp

it refers to retardation or delay in the response of an instrument to a change in the input signal. The measurement lags are of two types

ot

.c o

2. Measuring lag

17

3. Fidelity: Fidelity of a system is defined as the ability of a system to reproduce the output in the same form as the input.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

Dynamic error is difference between the true value of the quantity changing with the time and the value indicated by the instrument if no static error is assumed.

og

sp

ot

4. Dynamic error:

.c o

18

Errors in measurement
ot
Error: There is always some difference between the Errors are mainly classified as Gross errors Systematic errors Random errors

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

actual value and observed value is called error.

sp

.c o

19

Errors
.c o
1.

w w

This error can be eliminated by 1. Great care should be taken in reading and recording the data. 2. Taking number of readings of same quantity and by number of observers.

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

Gross errors gross errors are largely due to human mistakes in reading instruments and recording and calculating measurement results.

og

sp

ot

20

2. Systematic errors:

c. Observational errors

ii) Due to misuse of the instruments iii) due to loading effects


by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE 21

w w

i) Due to inherent short comings in instrument

.e e

These errors are due to the following:

ee xc

a. Instrumental errors:

lu si v

e. bl

og

b. Environmental errors

sp

ot

a. Instrumental errors

.c o

They are classified as

INHERENT SHORT COMINGS IN INSRUMENT


These errors are inherent in instruments because of their mechanical structure. They may due to: Construction Calibration or operation of instrument or measuring devices Example: If the spring used for producing controlling torque of permanent magnet instrument has become week, the instrument will read high. These errors are eliminated by careful planning and recalibration.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

22

Misuse of instruments These errors are due to the fault of the Example:

w w

.e e

ee xc

An experimenter may fail to adjust the zero of instrument, poor initial adjustments.

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

experimenter than that of the instrument.

ot

.c o

23

Due to loading effects

Example: A well calibrated voltmeter may give a misleading voltage when connected across a high resistance circuit. Same voltmeter when connected across a low resistance circuit may give a more dependable reading. hence the voltmeter is said to have loading effect.
w w w .e e ee xc
by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

These errors are committed by beginners, is the improper use of instrument


.c o m

24

Environmental Errors Errors which are introduced due to using an instrument in different conditions than in which it was assembled and calibrated are called environmental errors. These may due to Temperature Pressure Humidity Dust Vibration

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

25

ENVIRONMENTAL ERRORS

Automatic compensation employing devices for such deviation is also possible. Although new calibration may be made in the new conditions.
by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE 26

w w

.e e

If above condition is not possible then deviation in local condition must be determined and suitable correction to instrumental readings applied.

ee xc

lu si v

e. bl

Using instrument in controlled conditions of temperature and pressure

og

sp

ot

.c o

These can be eliminated by

Observational Errors The errors which occur due to improper observation made by the observer are called observational errors.
Example: The pointer of a voltmeter rests slightly above the surface of the scale. Thus an error on account of parallax will be incurred unless the line vision of the observer is exactly above the pointer. To minimize parallax errors , highly accurate meters are provided with mirrored by V.BALAJI, M.Tech,(P h.D), 27 AP/EEE ,DCE scales.

w w

.e e

ee xc

lu si v

e. bl

og

sp

ot

.c o

RANDOM OR RESIDUAL ERRORS Errors which occur due to the multitude of small factors which change or fluctuate from one measurement to another and are surely to change. The happenings or disturbances about which we unaware are lumped together and called random or residual. These are unpredictable errors.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

28

LIMITING ERRORS All components are guaranteed by the manufacturer have nominal value and a specified percentage of deviation (from the nominal value). the limiting of these deviations from the marked value are known as limiting errors. Fractional limiting error: The ratio of the error to the specified (nominal) magnitude of a quantity is called fractional error. It is expressed as,

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

29

Statistical evaluation of measurement of data


This is necessary to obtain the probable true value of the measured quantity. Systematic way of specifying this uncertainty is the systematic method The most probable value of a measured value can be estimated by following different methods are: a) Arithmetic mean b) Median c) Mode d) deviation from the mean e) Average deviation f) Standard deviation g) Variance

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

30

ARITHMETIC MEAN
Arithmetic mean is the average number of values taken. The best approximation will be made when the number of readings of the same quantity is very large. The Arithmetic mean is given by the following expression X= X1+X2+X3+.+Xn = X n n
Where X X1,X2,X3. n

lu si v

w w

.e e

= = =

e. bl

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

og

sp

Arithmetic mean Readings taken number of readings

ot

.c o

31

Median Median is also indicate the most probable value of the measured quantity when a set of readings taken.
When the readings are arranged an ascending and descending order of magnitude , the middle value of the set of readings is taken as the median.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

32

MODE Mode is the value which occurs frequently in a set of observations and around which other readings of the set cluster densely.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

33

DEVIATION FROM THE MEAN Deviation is the departure of a given reading from the arithmetic mean of the group of readings. If the deviation of first reading X1 is called d1 , and that of second reading X2 is called as d2 and so on , then the deviations from the mean can be expressed as, d1 = X1 X d2 = X2 X , etc.

Deviation from the mean may be positive or negative. But sumV.BALAJI, M.Tech,(P h.D), of the deviation is zero. by
AP/EEE ,DCE 34

w w

.e e

ee xc

lu si v

e. bl

og

sp

ot

.c o

Average Deviation Average deviation is defined as the sum of the absolute values of the deviation D= |d1| +|d2|+|d3|+|dn| n D = |d| n

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

35

STANDARD DEVIATION

The standard deviation or root mean square deviation of an infinite number of data is the square root of the sum of all the individual deviation squared ,divided by number of readings. It is expressed as o = d12 + d22+d32+.+dn n

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

Standard deviation or root mean square deviation is a very valuable aid in statistical analysis of random errors.

og

sp

ot

.c o

36

Standard deviation for a finite number of data (less than 20) O = d12 + d22+d32+.+dn2 n -1
0 =

w w

.e e

ee xc

d2 n-1

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

37

VARIANCE The variance is the mean of square deviation ,which is same as standard deviation, except that square root is not extracted . variance ,V = d12 + d22+d32+.+dn2 n =

w w

d2 n

.e e

ee xc

lu si v

e. bl

og

sp

ot

.c o

When number of observation less than 20, V =

d2 n-1
38

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

STANDARDS
A standard is a physical representation of a unit of measurement. The term standard is applied to a equipment having a known measure of physical quantity. They are used for the purposes of obtaining the values of the physical properties of other equipment by comparison methods.
Standards of Measurement classified by their function and application in the following categories:
ii. iii. iv.

w w

.e e

i.

International standards Primary standards Secondary Standards Working Standards


by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE 39

ee xc

lu si v

e. bl

og

sp

ot

.c o

STATIC CALIBRATION OF INSTRUMETS


.c o .e e ee xc
by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

CALIBRATON:

It is defined as the process by which all the static performance characteristics are obtained in one form or another. Calibration is used to find errors and accuracy.
40

w w

STATIC CALIBRATION :

lu si v

Calibration is defined as the comparison of an instrument with a primary or secondary standard of an instrument of known accuracy.

e. bl

og

sp

ot

Calibration procedure may be classified as


.c o e. bl og sp ot

Primary calibration:

Instrument is calibrated against primary standards . Examples: standard resistor and standard cell After calibration, that instrument s called as secondary calibration.
w w w .e e ee xc lu si v

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

41

Secondary calibration
Secondary calibration instrument is used for further calibrating another instrument of lesser accuracy.
Widely used in laboratory practice as well as in industry.

Example: Standard cell may be used for calibrating a voltmeter or ammeter with a suitable circuit.

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

42

Direct calibration with known input source


Same order of accuracy as primary calibration. Instruments which calibrated directly are used as secondary calibration instruments. Example: flow meter
w w w ee xc lu si v e. bl og sp ot .c o m

.e e
by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

43

Indirect calibration
Equivalence of two different instruments used for measurement of certain physical quantity. Consider two flow meters having similarity Reynolds number i.e.,
ee xc lu si v .c o m

D11V1 = D22V2 D11V1 D22V2 1 2


w w w

.e e

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

e. bl

og

Where, D - diameter of the pipe density of the fluid V velocity of fluid stream
44

sp

ot

ROUTINE CALIBRATION periodically checking the accuracy and proper functioning of the instrument with standards. Usual steps of calibration: Visual inspection of the instrument for the obvious physical defeats. Checking the instrument for proper installation in accordance with the manufacturer specifications.
w w w .e e ee xc
by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

1.

2.

lu si v

e. bl

og

sp

ot

.c o

45

w w

.e e

ee xc

5.

Recommended operation tests to detect to major defects.

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

4.

Leveling of instruments which needs this precaution.

sp

ot

.c o

3.

Zero setting of all the indicators.

46

LIMITING ERRORS
Limiting of these deviations from the marked values are known as limiting errors or guarantee errors Fractional or relative limiting error: The ratio of the error to the specified (nominal) magnitude of a quantity is called fractional error. r = A = Aa As (or) A = r As As As

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

47

w w

.e e

Actual value of the quantity , Aa =As + A = As + r As = As (1 + r ) Percentage limiting error % r = r x 100 Where Aa = Actual error As = specified value A = limiting error

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

48

Problem 1
Two resistors having the following ratings: R1= 36 + 5% and R2 =75 + 5%. Calculate the limiting error when the resistors are connected in series and connected in parallel. Solution: R1= 36 + 5%
Rl = 36+1.8 (max) and Rl = 36-1.8 (min) 36Limits of R1 are 37.8 and 34.2 Limits of R2 are 78.75 and 71.25

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

49

R = R1 + R2 = 37.8 +78.75 = 116.55(max) or R = R1 + R2 = 34.2+71.25 =105.45(min) Rated value =36 +75=111 Limiting error = 116.55-111 116.55= 105.45

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

Series connection:

50

Parallel connection
.c o m w w
R = R1R2 / (R1 + R2) = 78.75 x 37.8 /(78.75 + 37.8) = 25.54 Rated value of parallel resistors = 75x36 /(75+36) = 24.32 Limiting error = 25.54 -24.32 = 1.22

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

51

Problem no:2
A 0 10 A ammeter has guaranteed accuracy of 1.5% of full scale reading. The current measured by the instrument is 2.5 A. calculate the limiting values of current and the percentage limiting error. Solution: Given: Full scale reading = 10A limiting error r = 1.5% of full scale reading specified value As = 2.5 A

w w

.e e

ee xc

by V.BALAJI, M.Tech,(P h.D), AP/EEE ,DCE

lu si v

e. bl

og

sp

ot

.c o

52

Magnitude of limiting error of ammeter is A=1.5x10/100 =0.15A Relative error, er = A = 0.15 = 0.06 As 2.5 Limiting value of current = As (1 + r ) = 2.5(1 + 0.06) = 2.5+0.15A Percentage limiting error % r = r x 100 =0.06x100 =6%

w w

.e e

by V.BALAJI, M.Tech,(P h.D), AP/EEE M.Tech,(P h.D), ,DCE

ee xc

lu si v

e. bl

og

sp

ot

.c o

53

Das könnte Ihnen auch gefallen