Sie sind auf Seite 1von 5

Document No TITLE OF DOCUMENT Rev.

No 0A PROJECT PHASE SUB PROJECT PLANT DHRUV-MANDIDEEP DETAIL ENGINEERING FLAMMABLE SHED MDP-BHOPAL DISCIPLINE REFERENCE DOC. FORMAT ISSUED STRU Date 9-Jul-12 Prepared By ATB/SMA

DHRUV-S-SY-BOQ-001 Checked By RAJE Approved By ARUP

A3/A4 SIZE FOR REVIEW UNIT (MTRS/ KG/ TON/ NO.)

Sr. No. A 1

DESCRIPTION/ SPECIFICATIONS EARTH WORK Earthwork excavation in all types of soil up to the required depth from the existing ground level for foundations to required line, level and grades in both dry and wet condition including shoring, strutting, bailing and pumping out water from all sources, dressing of sides, ramming of bottoms, stacking the excavated material clear from the edges of the trenches and disposal of soil as directed by the engineer within the site, all materials and labour complete in all respects. Filling with selected earth in layers not exceeding 200mm depth consolidating deposited layer by watering, thorough mechanical ramming to 98% of Proctor's density and dressing etc., all materials and labour complete with all respects. i) From natural ground level to 2 m below ii)Providing and Laying Dry Stone Rubble packing/soling of 300mm compacted thickness with hard stones set in regular lines, intertices filled and compacted with small chips/stone grits or any other approved filler material, watering, dressing.Compaction by 10 ton roller or by ramming with heavy rammers or using vibratory compactors.

QUANTITY

MAKE

REMARK

m3

802

m3

150

m3

95

iii) Bringing selected murrum from outside the site wherever available and depositing in places 1700 mm thick , breaking clods, watering, and consolidation by power roller of required capacity to obtain 95% proctor density etc.

m3

530

PLAIN CEMENT CONCRETE (PCC) Providing and laying PCC 1:4:8 below foundations using 20 mm gauge down stone aggregates, machine mixed, mechanically vibrated and cured properly in leveling course including formwork, if required, all material and labour complete in all respects. REINFORCED CEMENT CONCRETE (RCC) Providing and laying at all levels RCC of grade M30 using OPC & 20 mm gauge & down machine crushed stone aggregates, machine mixed, mechanically vibrated and properly cured, all material and labour complete in all respects.

55 m3

m3

207

SHUTTERING Supplying, fabricating, erecting and fixing in position with bolts and nuts, nails and ties, etc. centering and shuttering to correct line and levels, propping, etc. with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof to avoid leakage of mortar, dismantling and removing the aforesaid assembly after the concrete attains the required strength, all material and labour complete in all respects.

m2

190

Document No TITLE OF DOCUMENT Rev.No 0A PROJECT PHASE SUB PROJECT PLANT F Sr. No. DHRUV-MANDIDEEP DETAIL ENGINEERING FLAMMABLE SHED MDP-BHOPAL DISCIPLINE REFERENCE DOC. FORMAT ISSUED STRU Date 9-Jul-12 Prepared By ATB/SMA

DHRUV-S-SY-BOQ-001 Checked By RAJE Approved By ARUP

A3/A4 SIZE FOR REVIEW UNIT (MTRS/ KG/ TON/ NO.)

REINFORCEMENT DESCRIPTION/ SPECIFICATIONS Providing and decoiling wherever necessary, cutting, bending, placing and fixing in position reinforcing conforming to Fe415 grade steel of all diameter for reinforcement in all cast-in-situ reinforced concrete works at all levels and height and tying with 18 gauge annealed GI binding wire, providing and fixing cement cover blocks, all material and labour complete in all respects. (Only laid weight shall be measured including authorized. laps. Cuts and wastages shall not be measured for payment. Rate shall include rolling margin of 3% for reinforcement ) STRUCTURAL STEEL Providing, fabricating, erecting and fixing in position of steel structures at all elevations using fusion welding quality steel conforming to IS:2062Grade/Classification E250(Fe410W) (as required and indicated in drawings) , including cutting, welding or bolting, supply of bolts/nuts/washers etc. complete as per drawings including surface preparation conforming to SA 2 1/2 according to and applying one coat of Epilux 4 Zinc Rich HB ESR Primer of not less than 50 microns and two intermediate coats of Epilux 455HB MIO(Micaceous Iron Oxide) of not less than 75 microns and two coats of Bergerthane Acrylic PUHB coat of not less than 50 microns (one coat after completion of fabrication at fabrication yard and the final coat just before despatching for erection), all material and labour complete. (shall include cost of washers, welding and electrodes required for the work and Transportation, if any,from Contractors' yard to the site) Payment for quantity shall be worked out from the final drawings used for construction.This Beams, columns,main , secondary members, sag rod, sag angle, etc. These may be Standard Sections available in market or made out of standard sections with suitable detailing/ stiffening(Eg. With gusset plates,Batten plates, lacing plates etc).

QUANTITY

MAKE

REMARK

MT

10

MT

35

COLD FORMED STEEL Supplying, fabricating, erecting and fixing in position steel structures at all elevations using light weight cold form sections of minimum tensile strength of 450Mpa conforming to IS:1079, IS:811,IS:801, including surface preparation by sand blasting in accordance with grade SA 21/2 and applying two coats of zinc phosphate primer of not less than 25 microns DFT/ coat and two coats of Epoxy Polyamide paint of not less than 25 microns DFT/ coat as per specification one coat before erection and the final coat after erection and all material and accessories like studs, gussets, screws, etc and all material and labour complete. ANCHOR BOLT Providing and fixing in position holding down bolts of property class 8.8 for steel columns, trusses and equipments in concrete or masonry of various diameters ranging from 12mm to 50 mm including nuts, washers, sleeves ,etc. as per drawings including supply and fixing templates ,supports ,setting out etc. complete as specified and directed (templates and support will not be measured and paid separately)

MT

7.2

MT

0.05

Document No TITLE OF DOCUMENT Rev.No 0A PROJECT PHASE SUB PROJECT PLANT J Sr.K No. DHRUV-MANDIDEEP DETAIL ENGINEERING FLAMMABLE SHED MDP-BHOPAL DISCIPLINE REFERENCE DOC. FORMAT ISSUED STRU Date 9-Jul-12 Prepared By ATB/SMA

DHRUV-S-SY-BOQ-001 Checked By RAJE Approved By ARUP

A3/A4 SIZE FOR REVIEW UNIT MT (MTRS/ KG/ TON/ NO.) 0.42 QUANTITY

INSERT PLATE/BASEPLATE DESCRIPTION/ WATER PROOFING SPECIFICATIONS Providing and laying the following items for water proofing in the sequence as listed below 3mm thick polyester reinforced APP modified bituminous waterproofing membrane including primer coat as per manufacturer's specification, all material and labour complete in all respects. Providing waterproofing to walls and sides of foundations. Protection board to protect water proofing membrane shall be preformed semi rigid asphalt boards 6 mm thick formed of selected blend of asphalt and mineral fillers reinforced with asphalt saturated felt on one side and fiberglass matt weather coated and with a bond breaking film on the other side. MISCELLANEOUS Anti-termite treatment Providing pre- constructional anti-termite treatment and creating a continuous chemical barrier by using Chlorpyrifos emulsifiable concentrate 20% with 1% concentration under raft slab and beam and all-round the raft, column pits, trenches, pits, tunnels, wall trenches, back fill, plinth filling, junction of wall upto natural ground level, surrounding of pipes, expansion joints, etc. (The treatment shall be carried out strictly accordance with IS6313(Part-2).) Laying of 1000G or 250micron or 0.25mm polyethylene sheet over levelled ground to house blinding concrete above below grade slab etc., including all laps at ends, material and labour in all respects. GROUTING Providing and laying non-shrinking cement grout under base plates of static strucutres/equipments, steel columns, etc., for grouts of thickness shown in drawings and filling of pockets of foundations & curing, cleaning out pockets, etc., complete as per drawings and Minimum thickness shall be 40mm, inclusive of proprietary cementitious (Conbex GPI or approved equivalent) in proportions specified by manufacturer to get a minimum 28 day compressive strength of 40MPa laid as per manufacturer's specification.

MAKE

REMARK

m2

185

185 m2

L 1

495

m2

m2

340

m3

0.09

POLY SULPHIDE SEALANT

m3

1.5

LARSEN & TOUBRO LIMITED


INTEGARTED ENGINEERING SERVICES
PROJECT. Doc. NO. DHRUV-MANDIDEEP DHRUV-S-FS-BOQ-001
JOB NO. REV. No. A CALCULATED ATB/SMA

PARTICULARS FLAMMABLE SHED Sub Head - I Sl No. Item No. Description of Items Unit Quantity

Unit Rate

Assumption & Exclusions: 1 2 3 4 5 6 7 8 Architectural quantity not included Dewatering is not included No water proofing is considered below grade slabs No wastage is considered for reinforcement and structural steel. Excavation quantities are provided by assuming 2:1 (Vertical:Horizontal) slope. All the building dimensions are considered as per the Work sheet enclosed. Safebearing capcity is considered as 750 kN/m2 below 2m from finished ground level. This BOQ gives the information about only the structural quantities.

TENTATIVE
SHEET DATE 7/9/2012 CHECKED RAJE Amount

Das könnte Ihnen auch gefallen