Errata Measures Thermal Measurements Thermal Power Calculations Power and Energy Densities COP Heat After Death
Errata
Inner Cylinder Hypothesis The inner cylinder hypothesis are wrong when it comes to radiation. The inner cylinder will only radiate from the area of the cylinder opening. This estimate was due to melting problems when trying to seal the openings. Heat was probably convected away through the openings in higher amounts but this has now been omitted in this Errata report.
Area
Weight
All parts were dissembled and weighted: Outer Cylinder: 1272,7 g Inner Cylinder: 705,4 g Ceramic Resistors: 2292,8 g Ceramic Washers: 24,4 g Putty: 27,7 g Active Material: 20,38 g Total Weight: 4343,4 g
The central thing for power and energy density measurements will be the weight of the active material.
Temperature
Temperature Measurements Measured by IR Camera Precision +/- 0.1 C Data taken by snapshots every minute for 420 minutes 150 x 120 measure points Emissivity set to 1 to only account for Radiant Temperature ECAT HT Key Resolution 128 x 32 measure points
Emissivity
Emissivity is defined,
e = Pg/Pb,
Kinetic Temperature, Tk Radiant Temperature, Tr Tr=e1/4Tk
IR Camera Measures Tr and calculates Tk by entering the emissivity, e. If set to, e =1, then one reads Tr .
Radiation
Convection
Conduction
As is seen from the setup there will also be heat losses due to conduction. In this case there can be heat conduction through the wirings and also from the steel framework. This amount has been impossible to estimate and is therefore omitted in the calculations.
Power
Power vs Time Max Output Power 8.4 kW Max Radiation: 7.5 kW Max Convection:0.9 kW Max Input Power 3.6 kW COP at Maximum 2.3 Energy vs Time Total Output 17.9 kWh Total Input 8.3 kWh Total Radiation Output 14.9 kWh Total Convection Output 2.9 kWh Avg COP: 2.2
COP
COP vs Time Drops because Input Power Steps Max measured value 3 Initially falls with power but at the end recovers
Avg COP vs Time Avg COP around 2.2 The increase in the end is due to Heat After Death and the early losses are due to Heat Capacity in the materials
Conclusion
The Rossi effect is verified The Power source can not be of chemical nature