Sie sind auf Seite 1von 57

For PASOLINK +

NEC International Training, Ltd.

PNMT - GENERAL
PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT HAUL RADIO TRANSMISSION NETWORK. PNMT IS DESIGNED AS AN ONSITE MAINTENANCE TOOL TO BE USED BY THE FIELD ENGINEERS AND TECHNICIANS. IT CONNECTS DIRECTLY TO THE PNMT PORT OF THE PASOLINK IDU. PNMT CAN BE USED TO MONITOR LOCAL / REMOTE EQUIPMENT STATUS AND PROVIDES CONTROL CAPABILITIES SIMILAR TO THOSE AVAILABLE IN PNMS. PNMT IS ALSO USED TO DOWN LOAD SYSTEM AND CONFIGURATION FILES TO THE NE AND UPGRADE THE SOFTWARE IN THE IDU WHEN CONNECTED TO AN IDU PNMT CAN MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT ANY REMOTE NETWORK ELEMENT UNDER THE CONTROL OF THE CENTRAL PM.

PNMT

FUNCTIONS

MICROSOFT WINDOWS 98/NT/2000/XP WORKSTATION GRAPHICAL USER INTERFACE ONE HOP LINK DISPLAY ON THE PNMT SCREEN COMMUNICATE WITH REMOTE NEs ON THE SAME NETWORK COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE NEs TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE CTRL MODULES SEVERAL LEVELS OF LOGIN / LOGOUT EVENT LOGGING WINDOW PERFORMANCE MONITORING FUNCTION WINDOW LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION LOCAL/REMOTE PM CONFIGURATION MANAGEMENT LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE

PNMT

PNMT COMMUNICATION INTERFACE


COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :

VIA THE PNMT PORT OF THE LOCAL PASOLINK EQUIPMENT


VIA THE DSC TO A REMOTE PASOLINK EQUIPMENT PNMT PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND CONSISTS OF A RJ45 CONNECTOR. PNMT PORT CONNECT THE PM CTRL MODULE IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT COMMUNICATION PORT OF THE PNMT COMPUTER.

PROPERTIES OF THE PNMT PORT ARE AS FOLLOWS:


PORT CONFIGURATION RS-232 CONNECTOR TYPE RJ45 BITS PER SECOND RATE1200 TO 19200 Default(19200)

PNMT PORT

PNMT

HARDWARE/SOFTWARE CONFIGURATION
RECOMMENDED PNMT MOBILE PC CONFIGURATION LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE) CPU: PENTIUM-II 500 MHz OR HIGHER RAM: 128 MB OR MORE HDD: 5 GB OR MORE FDD: 3.5INCH CD-ROM: 8 x OR HIGHER INTEGRATED SOUND CARD AND SPEAKER SOFTWARE CONFIGURATION ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD DISK AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM OPERATING SYSTEM WINDOWS 98 (ENGLISH VERSION) OR WINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION) WINDOWS 2000 (ENGLISH VERSION) WINDOWS XP (ENGLISH VERSION) APPLICATION PROGRAM NEC PNMT SOFTWARE
PNMT

START UP
CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU PNMT PORT USING A RS232C CABLE

DOUBLE CLICK ON THE PNMT SHORTCUT ICON ON THE DESKTOP OR CLICK ON START>>PROGRAM>>PNMT>>PNMT

PNMT PROGRAM STARTUP AND TRIES TO GET CONNECTED TO THE PASOLINK EQUIPMENT

AFTER CONNECTING TO THE PASOLINK EQUIPMENT TRIES TO ACQUIRE DATA FROM THE LOCAL EQUIPMENT AND THE REMOTE EQUIPMENT TO DISPLAY ON THE LINK SUMMARY WINDOW

PNMT

SHUT DOWN
IF YOU HAVE NOT LOGIN FIRST THE EXIT MENU CANNOT BE SELECTED.

TO EXIT THE PNMT PROGRAM CLICK ON EXIT IN THE SYSTEM DROPDOWN MENU AND CLICK YES.

IN THE DIALOG BOX THAT OPENS CLICK YES

THE SCREEN INDICATES NOW PNMT SHUTDOWN. IT WILL TAKE FEW MINUTES TO SHUTDOWN

PNMT

PNMT MAIN SCREEN


PNMT MAIN SCREEN IS SPLIT IN TO TWO TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.
PNMT WINDOW MENU BAR COMMON TOOL BAR LINK SUMMARY WINDOW NE-SPECIFIC MENU ITEMS

BLOCK DIAGRAM

NE-SPECIFIC DATA

CLICK ON THE ARROW ICONS IN THE MIDDLE OF THE SCREEN TO EXPAND THE LEFT OR RIGHT DATA WINDOW. CLICKING ON THE BLOCK WILL RETURN THE ORIGINAL SPLIT SCREEN.

TAB SELECTION FOR OTHER EQUIPMENT VIEWS SELECTED NE OPPOSITE NE LOGIN INFORMATION

PNMT

PNMT MAIN SCREEN


COMMON MENU BAR
COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEM HAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE. COMMON TOOL BAR COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS LINK SUMMARY WINDOW LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP). THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS WINDOW NE SPECIFIC DATA : NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM. NE SPECIFIC MENU ITEMS: EQUIPMENT CONFIGURATION EQUIPMENT SETUP PROVISIONING MAINTENANCE

EVENT LOG LINK PERFORMANCE MONITOR


TAB SELECTION

DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P CTRL AND VERSION) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.

NE BLOCK DIAGRAM:
STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND CTRL) ARE SHOWN IN THE BLOCK DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,

PNMT

PNMT WINDOW MENU ITEMS

SYSTEM

REFRESH

HELP HELP ABOUT DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT DISPLAY THE PNMT VERSION NUMBER THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY AND TO UPDATE EQUIPMENT INFORMATION THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE USER NAME AND PASSWORD. THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW

LOGIN / LOGOUT CHANGE PASSWORD ALARM BUZZER CONNECT EXIT THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN THE NETWORK THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND DEFINE THE BUZZER SOUND

PNMT

10

NE SPECIFIC MENU ITEMS


CONFIGURATION EVENT LOG LINK PERFORMANCE MONITOR
THIS FUNCTION DOWN LOAD THE PERFORMANCE DATA FROM THE SELECTED NE AND OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.

THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND DISPLAY THE INFORMATION IN EVENT LOG WINDOW FREQUENCY SETTING EQUIPMENT SETUP PROVISIONING MAINTENANCE MTPC / ATPC MODE

FRAME ID
INTERFACES REDUNDANCY SELECT

MAINT MODE ON/OFF NEAR END LOOPBACK FAR END LOOPBACK IF LOOPBACK SWITCHOVER (1+1)

OH ASSIGNMENT MTPC STATUS ATPC STATUS BER THRESHOLD

TX MUTE ON/OFF
CW ON/OFF ATPC MANUAL

PNMT

11

PNMT LOGIN / LOGOUT & EXIT


CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN THE LOGIN/LOGOUT WINDOW

TO LOGIN SELECT LOGIN IN THE LOGIN/LOGOUT WINDOW. ENTER THE USER NAME ACCORDING TO THE PRIVILEGES AND THE PASSWORD. CLICK OK TO LOGIN TO PROTECT THE NETWORK AND NETWORK MANAGEMENT SYSTEM FROM UNAUTHORIZED ACCESS OR MODIFICATIONS, FIVE LEVELS OF USERS ARE DEFINED WITH DIFFERENT PRIVILEGES. THE FUNCTIONS AVAILABLE DEPENDS ON THE USER ACCESS LEVEL, (SEE THE TABLE NEXT PAGE)

TO LOGOUT SELECT LOGOUT IN THE LOGIN/LOGOUT WINDOW AND CLICK OK.

PNMT

12

USER NAMES & PRIVILEGES

PNMT

13

USER NAMES & PRIVILEGES

PNMT

14

MODULE DETECTED SYMBOL


If IDU detects the difference between the module configuration and currently inserted modules in the slot(s), module detected symbol ( ! ) will be flashed in the block-diagram portion of the PNMT screen. You can click on this symbol to be redirected to the Equipment Setup window or go to Configuration Equipment Setup Slot/LAN tab to synchronize the module configuration.

PNMT

15

OVERALL WINDOW
OVERALL WINDOW FOR (1+0) CONFIGURATION OVERALL WINDOW FOR (1+1) CONFIGURATION

OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION: WHEN MTPC MODE IS SELECTED, MTPC POWER LEVEL

TX AND RX FREQUENCIES USED


FRAME ID USED TX POWER CONTROL MODE SELECTED (ATPC OR MTPC) SLOT1 THE CURRENT SETTING OF SLOT1. SLOT2 THE CURRENT SETTING OF SLOT2. MODULATION THE CURRENT MODULATION TYPE USED. SELECTED TX AND RX CHANNEL IN (1+1) CONFIGURATION CLICK THE OVERALL TAB TO DISPLAY THE OVERALL WINDOW

TRANSMISSION CAPACITY SHOWS THE TRANSMISSION CAPACITY OF THE SYSTEM.

PNMT

16

ODU WINDOW
CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS OR CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS

ODU WINDOW FOR (1+1) CONFIGURATION

ODU WINDOW FOR (1+0) CONFIGURATION

PNMT

17

ODU DETAIL
Monitored Items in the ODU

Following items are monitored.


TX PORTION Alarm o TX INPUT: alarm occurs when the TX IF input signal from the IDU is lost o TX POWER: TX RF Power decreases 3 to 6 dB from nominal value. o Selected/Not Selected: shows the current system used for signal transmission. (for 1+1 systems only) Metering TX Power: The transmitted power of the ODU in dBm. RX PORTION Alarm o RX LEVEL: alarm occurs when the input level decreases by preset value from squelch level. o Selected/Not Selected: shows the current system used for signal reception. (for 1+1 systems only) Metering

RX Level: The received level interpreted in dBm.


COMMON PORTION Alarm o APC: this alarm occurs when the Local Oscillator is locked out. o ODU CPU: this alarm occurs when the communication between the ODU and the IDU is lost. Metering Power Supply: Display PS voltage value (V)

PNMT

18

IDU WINDOW
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS OR CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS IDU WINDOW FOR (1+0) CONFIGURATION IDU WINDOW FOR (1+1) CONFIGURATION

PNMT

19

IDU DETAIL

Monitored Items Following items are monitored: MODULE Alarm o MODEM: alarm occurs if there is a modem failure. o Power supply: alarm occurs if the power supply fails. o MAIN BOARD: alarm occurs when the INTFC module or CPU (SUB) fails. o TNS/PNMS CARD: alarm occurs if when TNS Card or PNMS Card in Slot1 fails. o INTFC-S: alarm occurs when the LAN INTFC-S Card or 2M INTFC-S (8x2M) Card in Slot2 fails. MODEM TX Alarm o MOD: alarm occurs when the TX unit (modem) failed. Status o Selected (for 1+1 systems only) RX Alarm o DEM: alarm occurs when the RX unit (demodulator) fails or the IF signal is lost. o LOF: loss of frame occurred. o HIGH BER: alarm occurs if the signal is deteriorated below the threshold value. o LOW BER: alarm occurs if the signal is deteriorated below the threshold value.

PNMT

20

IDU DETAIL
Status o Selected (for 1+1 systems only) ODU INTFC Alarm o IF CABLE SHORT: alarm occurs when the cable between IDU and ODU is shorted. o ODU CPU: alarm occurs when the connection between IDU and ODUdisconnects.

COMMON Metering BER: The current overall value of the Bit-Error-Rate

MAIN INTFC Alarm/Status o USAGE ERROR: alarm occurs when 2MB bipolar signal is inputted into the channel that has been chosen Not Used.

o INPUT LOSS: alarm occurs when 2MB bipolar signal is disconnected.


o OUTPUT LOSS: alarm occurs when the received signal from radio link is lost. o AIS RECEIVED: indicates the status of AIS RECEIVED signal for transmitting channel in the MAIN INTFC. o AIS GENERATED: indicates the status of AIS generation signal for receiving channel in the MAIN INTFC.

LAN INTFC-S o Port Usage: enables to apply the each port.

o Link: alarm occurs when the link fails on each port.


o Speed & Duplex: indicates the status of Speed & Duplex. o Collision: indicates the status of Collision. o Link Loss Forwarding: indicates the status of Link Loss Forwarding.

PNMT

21

CHANGE PASSWORD

CLICK ON CHANGE PASSWORD IN THE SYSTEM DROPDOWN MENU TO OPEN THE CHANGE PASS WORD WINDOW.

ENTER THE OLD PASSWORD

ENTER THE NEW PASSWORD

RE-ENTER THE NEW PASSWORD TO CONFIRM

CLICK OK TO CHANGE THE PASSWORD. CLICK CANCEL TO EXIT WITHOUT CHANGING PASSWORD

PNMT

22

ALARM BUZZER
CLICK ON ALARM BUZZER ON THE SYSTEM DROP DOWN MENU TO OPEN THE ALARM BUZZER SETTING WINDOW. SELECT NO SOUND TO DISABLE THE BUZZER

SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER SOUND CAN BE CHANGED BY SELECTING A DIFFERENT WAV FILE. USE BROWSE TO LOCATE THE PATH TO THE WAV FILE. CLICK HERE TO TEST THE BUZZER SOUND

CLICK OK TO IMPLEMENT THE OPTION SELECTED OR CLICK CANCEL TO EXIT WITHOUT CHANGING THE SETTINGS.

SELECT BEEP TO ENABLE THE BUZZER WITH BEEP FREQUENCIES INSTEAD OF WAVE FILE SOUND BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.

PNMT

23

SEARCH / CONNECT TO NETWORK ELEMENT


CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.

LIST MENU

CLICK THE SEARCH FOR NETWORK ELEMENT TO SEARCH AND LIST THE OTHER NEs IN THE NETWORK

TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE DISPLAYED IN THE LINK SUMMARY WINDOW.
TOOL BAR ITEMS

CONNECT TO NETWORK ELEMENT SEARCH FOR NETWORK ELEMENT

PNMT

24

HELP FUNCTION
PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN PDF FILE FORMAT. IF THE ACROBAT READER IS INSTALLED IN THE PNMT PC, CLICKING HELP AND SELECTING THE RELEVANT PNMT FILE WILL OPEN THE PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.

BUZZER STOP ICON IS ACTIVE ONLY WHEN THE ALARMED EQUIPMENT DISPLAY WINDOW IS SELECTED FROM THE TABs OR FROM THE BLOCK DIAGRAM SYMBOLS.
REFRESH - OPEN THE NE LIST WINDOW CONNECT - OPEN THE NE LIST WINDOW OPEN THE LOGIN/LOGOUT WINDOW DISPLAY THE PNMT SOFTWARE VERSION INFORMATION

PNMT

25

EQIPMENT SETUP
Main signal, Service signal, ODU and CTRL portion can be monitored and controlled in this window.
To open the Equipment Configuration Monitor: 1. Select Configuration Equipment Setup in the NE-specific menu bar. 2. This window contains the setup information and control for the ODU and the IDU. The Equipment Setup window is shown below.

PNMT

26

EQUIPMENT SETUP
To setup the ODU and IDU parameters:

Click on the [Setup] button in the Equipment Setup window.

PNMT

27

EQUIPMENT SETUP
On both Equipment Tab and Slot/LAN Tab of Setup window, the configurable items are shown and described in the table below:

PNMT

28

EQUIPMENT SETUP
Frequency Channel
1. Click on [Browse] to locate the Channel plan file on the local hard disk. 2. Select Channel and click on [OK], then TX and RX frequency corresponding to the channel will be set. Frequency channel file format is csv, including channel name, TX frequency and RX frequency. Examples CH-1, 7442.000, 7603.000 CH-2, 7603.000, 7442.000

PNMT

29

CONTROL SETTING
FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE NAME BUTTON TO OPEN THE NE NAME SETTING WINDOW. THE NAME ENTERED TO IDENTIFY THE NETWORK ELEMENT CAN BE CHANGED FORM THIS WINDOW. A MAXIMUM OF 32 CHARACTERS CAN BE USED.

ENTER THE NAME AND CLICK EXECUTE TO SHOW THE NAME IN THE EQUIPMENT SETUP WINDOW. CLICK THE NOTE BUTTON TO OPEN THE NOTE WINDOW.

A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS CAN BE USED IN THIS FIELD ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE NOTE IN THE EQUIPMENT SETUP WINDOW.

PNMT

30

PROVISIONING
The main interface (MAIN INTFC), SC Assignment, MTPC and ATPC can be set in this window.

To open the Equipment Configuration Monitor:


1. Select Configuration Provisioning in the NE-specific menu bar. 2. This window contains the setup information of the MTPC, ATPC, BER Alarm Threshold, Cluster ALM Setting (Input), AIS Activation, Main Channel Setting, SC Assignment and LAN INTFC-S. The Provisioning window is shown below.

PNMT

31

ATPC SETTING
AUTOMATIC TX POWER CONTROL
ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR. VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER. IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM

PROVISIONING WINDOW RX THRESHOLD LEVEL


WHEN THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION. THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE STATION IS SET TO ATPC MODE

ADDITIONAL ATTENUATION
ADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH. (FOR PASOLINK+ TYPE ODU ONLY)

CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW.. AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING. IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW MAX HOLD: SET THE ODU OUTPUT TO THE ATPC MAXIMUM POWER LEVEL MINIMUM HOLD: SET THE ODU OUTPUT TO THE ATPC MINIMUM POWER LEVEL HOLD: SET THE ODU OUTPUT TO THE LEVEL AT THE TIME OF IDU-ODU CONTROL COMMUNICATION FAILURE.

THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE.

ODU ALARM MODE


THIS ITEM DEFINES THE ODU TRANSMIT POWER LEVEL WHEN CONTROL COMMUNICATION BETWEEN THE IDU AND THE ODU FAILS. WHEN THE TX POWER CONTROL MODE IS SET TO MTPC THIS ITEM IS NOT DISPLAYED.

PNMT

32

MTPC SETTING
MTPC TX POWER

MTPC TX PWR DEFINES THE ODU OUT PUT POWER IN MTPC MODE. THE VALUE ENTERED IS THE ATTENUATION LEVEL IN DB FROM THE MAXIMUM ODU OUTPUT POWER. IN ATPC MODE THIS MENU ITEM DOES NOT APPEAR.
IN THE PROVISIONING WINDOW THE MTPC STATUS IS ACTIVE WHEN THE TX POWER CONTROL MODE IS SET TO MTPC..

TO GET THE MAXIMUM OUTPUT POWER SET THE ATTENUATION TO 0DB.

RX THRESHOLD LEVEL IN MTPC MODE THIS VALUE IS SET, IN CASE THE OPPOSITE STATION IS SET TO ATPC MODE. THEN, IF THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION.

CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW..


AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING. IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW

ADDITIONAL ATTENUATION
ADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH. (FOR PASOLINK+ TYPE ODU ONLY) THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE. SETTING RANGE 1 TO 5 dB.

PNMT

33

PROVISIONING
BER Alarm Threshold
The BER in the system monitors the DMR section. The figure below illustrates these sections

High BER

Low BER

Cluster ALM Setting (Input) This function enables or disables the Cluster Alarm setting. 1. Click on the [Cluster ALM 1/2] button on the Provisioning window. 2. Select Enabled/Disabled depending on the desired state. 3. Click on [Execute] button to apply the new setting.

4. Click on [Close] button when finished.

PNMT

34

PROVISIONING
AIS Activation Condition To set the AIS Activation Condition: 1. Click on the [AIS Activation Condition] button on the Provisioning window. 2. Select LOF/LOF or High BER depending on the desired state. 3. Click on [Execute] button to apply the new setting. 4. Click on [Close] button when finished.

Main Interface Setting


Channel Usage Error Report This function is to enable or disable the Channel Usage Error Report function. This error is reported when 2MB bipolar signal is inputted into the channel chosen Not Used. To set the Channel Usage Error Report: 1. Click on the [Channel Usage Error] button on the Provisioning - Main Interface window. 2. Select Reported/Not Reported depending on the desired state. 3. Click on [Execute] button apply the new setting. 4. Click on [Close] button when finished.

AIS Received Report This function is to enable or disable the AIS Received Report function. To set the AIS Received Report: 1. Click on the [AIS Received Report] button on the Provisioning - Main Interface window. 2. Select Reported/Not Reported depending on the desired state. 3. Click on [Execute] button apply the new setting. 4. Click on [Close] button when finished.

PNMT

35

PROVISIONING
AIS Generated Report

This function is to enable or disable the AIS Generated Report function.


To set the AIS Generated Report: 1. Click on the [AIS Generated Report] button on the Provisioning - Main Interface window. 2. Select Reported/Not Reported depending on the desired state. 3. Click on [Execute] button apply the new setting. 4. Click on [Close] button when finished.

AIS Received Condition Setting This function enables to set the type of AIS Received Condition. To set the AIS Received Condition Setting: 1. Click on the [AIS Received Condition] button on the Provisioning Main Interface window. 2. Select Alarm/Status depending on the desired state. 3. Click on [Execute] button apply the new setting. 4. Click on [Close] button when finished. SC Assignment This function is to display the assigned interface type {LAN or RS-232C} of the available for user channels (DSC), and sets the type of directional interface for SC3 and SC4. Direction (for 1+0 (Expandable) and 1+1 system only) To set the type of directional interface for SC3 and SC4:

1. Click on the [Setting] button in the SC Assignment section on the Provisioning window.
2. On the ensuing window, you will be able to select the type of directional interface for SC3 and SC4. 3. Click on [Execute] button to apply the new setting. 4. Click on [Close] button when finished.

PNMT

36

PROVISIONING
LAN INTFC-S

PNMT

37

MAINTENANCE
There are several maintenance control items that can be executed in the maintenancemenu.
The function of each control is as follows.

MAINT: To switch Maintenance mode to ON TX Switch: To control the TX switch manually RX Switch: To control the RX switch manually

2Port LAN Reset: To reset LAN Ports of LAN INTFC-S interface


TX/RX Frequency: To set TX Frequency and RX Frequency Sub Band: To select Sub Band TX Mute: To turn off TX power IF Loopback: To create the INTFC/OPT INTFC of the selected NE CW (MOD Carrier): To turn on the Continuous Wave for measurements ATPC Manual: To use an optional transmitting power when the ATPC is in operation Shift Frequency: To select Shift Frequency (for 1+0(4x2M), 1+0(20x2M) only) Antenna Alignment Mode: To turn on Antenna Alignment Mode (only available for the specific type of ODU) Loopback-1, 2: To set the loop back at the near end or the far end *These windows are not available when MAINT is OFF. (Switch to Maintenance mode first is displayed.)

PNMT

38

MAINTENANCE
To open the Maintenance window: Select Configuration Maintenance in the NE-specific menu bar.

PNMT

39

MAINTENANCE
Selecting Maintenance Mode To switch the NE to maintenance mode: 1. Click [MAINT] button in Maintenance window. 2. Select on ON/OFF depending on desired state. 3. Click on [Execute] to carry out thecommand. 4. Click on [Close] button when finished

TX Switch (for 1+1 Hot Stand-by system only) To control the TX switch manually: 1. Click [TX Switch] button in Maintenance window. 2. Select the system that you want to use for the TX portion of the radio. The default setting is Auto. 3. Click on [Execute] button to switch the TX to the selected system.

RX Switch (for 1+1 system only) To control the RX switch manually: 1. Click [RX Switch] button in Maintenance window. 2. Select the system that you want to use for the RX portion of the radio. The default setting is Auto.

3. Click on [Execute] button to switch the RX to the selected system.


4. Click on [Close] button when finished.

PNMT

40

MAINTENANCE
2 Port LAN Reset To reset LAN Ports of LAN INTFC-S interface: 1. Click [2Port LAN Reset] button in Maintenance window. 2. Select the port that you want to reset. 3. Click on [Execute] button to reset LAN ports. 4. Click on [Close] button when finished.

TX/RX Frequency Sets the RF transmitted frequency and consequently its pair receiving frequency.

Sub Band Sub Band of ODU can be selected To select Sub Band: 1. Click [Sub Band] button in Maintenance window. 2. Select the type of Sub Band in the Sub Band list. 3. Click on [Execute] button to carry out the command. 4. Click on [Close] button when finished.

PNMT

41

MAINTENANCE
TX Mute status

TX power of the ODU is switched off when TX Mute is ON. This should be OFF in normal operation.
To change the TX Mute status: 1. Click [TX Mute] button in Maintenance window. 2. Select ON/OFF depending on the desired state. 3. When you are setting to the opposite NE, you have to also select TX Release Time in the TX Mute Release Time list. 4. Click on [Execute] button to carry out the command.

Loopback-1 (near-end loopback) This type loopback is created at the INFTC/OPT INTFC of the selected NE where you are currently connected. To set the near-end loopback: 1. Click on the [Loopback-1] button in the Maintenance window. 2. Select ON to activate the loopback. 3. Click on [Execute] button to apply the loopback. 4. Click on [Close] button when finished.

PNMT

42

MAINTENANCE

Loopback-2 (far-end loopback) This type loopback is created at the INFTC/OPT INTFC of the opposite NE. To set the far-end loopback: 1. Click on the [Loopback-2] button in the Maintenance window. 2. Select ON to activate the loopback. 3. Click on [Execute] button to apply the loopback. 4. Click on [Close] button when finished.

IF Loopback This type loopback is created at the INFTC/OPT INTFC of the selected NE. 1. Click on the [IF LoopBack] button in the Maintenance window. 2. Select ON to activate the loopback. 3. Click on [Execute] button to apply the loopback. 4. Click on [Close] button when finished.

PNMT

43

MAINTENANCE
CW (MOD Carrier) status When doing frequency measurements, the CW should be turned ON to have an unmodulated signal. During normal operations this status should be OFF. To change the CW (MOD Carrier) status: 1. Click [CW (MOD Carrier)] button in Maintenance window. 2. Click on ON/OFF button depending on desired state. 3. Click on [Execute] button to carry out the operation. 4. Click on [Close] button when finished.

ATPC Manual Use when an optional transmitting power is required when the ATPC is in operation.

To set the ATPC Manual:


1. Click [ATPC Manual] button in Maintenance window. 2. Select the whether to manually turn ON or OFF the ATPC manual and the ATPC manual power that will be transmitted in dB. 3. Click on [Execute] button to activate the new setting. 4. Click on [Close] button when finished.

PNMT

44

MAINTENANCE
Shift Frequency
The shift frequency function is used to select the type of shift frequency. This function is only available for 1+0 (4x2M) and 1+0 (20x2M) system configuration To select Shift Frequency: 1. Click [Shift Frequency] button in Maintenance window. 2. Select the type of Shift Frequency in the Shift Frequency window. 3. Click on [Execute] button to activate the new setting. 4. Click on [Close] button when finished.

Antenna Alignment Mode (only available for the specific type of ODU) The Antenna Alignment Mode function is used for extending the dynamic range of the RX

LEVEL MONITOR (ODU). This function is only available for the specific type of ODU.
To set Antenna Alignment Mode: 1. Click [Antenna Alignment Mode] button in Maintenance window. 2. Select ON/OFF button. 3. Click on [Execute] button to activate the new setting. 4. Click on [Close] button when finished.

PNMT

45

AUX I/O WINDOW MONITOR/CONTROL


AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS. CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY CONFIGURE CONTROL RELAY OUTPUTS CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE AND CONTROL THE EXTERNAL CONTROLS ENTER THE NAME TO APPEAR FOR SELECTED CONTROL ITEM ( UP TO 32 CHARACTERS) ENTER THE LABEL FOR EACH CONDITION EVENT ON AND EVENT OFF CLICK EXECUTE TO CARRY OUT THE CHANGE

ENTER THE SELECTED EXTERNAL ALARM NAME, (UP TO 32 CHARACTERS)

CONFIGURE ALARM INPUTS CLICK THE INPUT 1-6 BUTTONS TO CONFIGURE THE EXTERNAL ALARM

SELECT THE CONDITION FOR ALARM, EVENT ON OR EVENT OFF


EXTERNAL MONITORING ITEMS CAN BE DEFINED AS ALARMS OR AS STATUS CHANGE. CLICK EXECUTE TO CARRY OUT THE CHANGE

ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND EVENT OFF.

X.733 ALARM/SEVERITY SETTING

CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW

PNMT

46

RELAY CONFIGURATION
When Cluster ALM Setting (Input) is enabled, following Input items are used as Cluster ALM. 1. When Cluster ALM1 is enabled, Input-6 item is used as Cluster ALM1. 2. When Cluster ALM2 is enabled, Input-5 item is used as Cluster ALM2. RL01 TO RL03 ARE ASSIGNED TO MAINT, PS ALM AND CPU ALM AND CANNOT BE CHANGED. Relays RL04 to RL07 are available for allocation of Housekeeping (HK), Cluster alarms and equipment alarms. These alarms are outputted on the same relay.

CLICK THE RELAY CONFIGURATION BUTTON IN THE AUX I/O WINDOW TO OPEN RELAY CONFIGURATION SETTING WINDOW

SELECT THE NUMBER OF HOUSE KEEPING CONTROLS OR SELECT DISABLE.

CLICK EXECUTE TO CARRY OUT THE CHANGES

PNMT

47

CTRL WINDOW
CLICK THE CTRL SYMBOL ON THE BLOCK DIAGRAM OR THE CTRL TAB TO DISPLAY THE CTRL WINDOW FOR THE SELECTED NE.

CONFIGURATION AND SETTING OF THE PASOLINK MANAGEMENT CONTROL IS PROVIDED IN THIS WINDOW.

PNMT

48

DATE TIME SETTING


DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENTS PM CTRL CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM [CTRL WINDOW]

TO DISPLAY THE CURRENT DATE/TIME STORED IN THE NE, SELECT GET DATE/TIME AND CLICK EXECUTE. CLICK DATE/TIME BUTTON IN THE CTRL WINDOW TO OPEN THE DATE/TIME SETTING CONTROL WINDOW THE CURRENT DATE/TIME STORED IN THE PM CARD, IS DISPLAYED.

TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME. TO DISPLAY AND SET THE DATE/TIME SET IN THE PNMT PC TO THE NE, SELECT DISPLAY PC TIME BOX AND CLICK THE EXECUTE BUTTON.

TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME. CHANGE THE DATE /TIME SETTING AS REQUIRED, CLICK THE EXECUTE BUTTON.

PNMT

49

DOWN LOAD CONFIGURATION FILES


[CTRL WINDOW] THIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE NETWORK CONFIG TOOL TO THE CTRL IN THE SELECTED NETWORK ELEMENT. THERE ARE TWO FILES CREATED FOR EACH NE, MIB.CFG CONTAINS THE IP ADDRESS OF THE NE AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION. THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK NETWORK WHERE NE IS LOCATED. CLICK THE CONFIGURATION FILE BUTTON UNDER THE DOWNLOAD (PC>>CTRL) IN THE CTRL WINDOW, TO OPEN THE DOWNLOAD CONFIGURATION FILE WINDOW. DOWN LOAD SELECT EACH CONFIG FILE ONE BY ONE FROM THE TYPE WINDOW BROWSE AND SELECT THE PATH/LOCATION TO THE FILE SELECTED IN THE TYPE WINDOW. CLICK EXECUTE BUTTON TO DOWN LOAD THE SELECTED CONFIG FILE.. REPEAT THE DOWNLOAD PROCEDURE FOR THE OTHER CONFIG FILE.. A MESSAGE WINDOW INDICATE THE STATUS OF THE DOWNLOAD OPERATION AND IT WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS OVER

UPDATE AFTER THE SUCCESSFUL DOWN LOAD OF THE CONFIGURATION FILES. CLICK UPDATE BUTTON. UPDATE CONFIGURATION FILE WINDOW OPENS. SELECT THE APPROPRIATE BOX FOR THE TYPE OF CONFIGURATION FILE(S) THAT WILL BE UPDATED. CLICK EXECUTE BUTTON TO START THE UPDATE OPERATION.. WHEN UPDATING, PM CTRL TO PM CTRL COMMUNICATION WILL BE LOST WHEN CTRL INITIALIZES TO THE NEW SYSTEM CONFIGURATION. DURING THIS TIME PNMT CONNECTION TO THE PASOLINK WILL BE LOST BUT WILL AUTOMATICALLY BE RECONNECTED AFTER THE PM CTRL RESETS Network Config MIB Config
With ROM [CTRL Program] Switching

WARNING MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN LOADED TO THE CTRL IN THE CORRECT NE. INCORRECT CONFIGURATION FILE WILL LEAD TO CTRL OR NETWORK FAILURE MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE THE CTRL WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE CTRL FAILURE. CLICK CLOSE BUTTON WHEN DONE

Execute

PNMT

50

DOWN LOAD PROGRAM FILE


[CTRL WINDOW]
THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE CTRL. THIS OPERATION AFFECTS ONLY THE PM CTRL TO PM CTRL COMMUNICATION. AND WILL NOT DISRUPT THE RADIO LINK. CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>CTRL) IN THE CTRL WINDOW.

CTRL CAN BE RESET USING THIS FUNCTION CLICK THE CTRL RESET BUTTON ON THE CTRL WINDOW.

SELECT THE MODULE THE APPLICATION PROGRAM IS TO BE DOWNLOADED. ENTER THE PATH TO THE PROGRAM FILE TO BE DOWNLOADED OR CLICK BROWSE TO LOCATE THE PROGRAM FILE.

CLICK THE EXECUTE BUTTON TO START DOWNLOAD OPERATION


CLICK ON THE CPU RESET BUTTON TO SWITCH TO THE NEW PROGRAM FILE SELECT WITH ROM (PROGRAM) SWITCHING OPTION IF YOU WANT TO SWITCH TO A NEWLY DOWNLOADED CTRL PROGRAM FILE RESETTING THE CTRL WILL NOT AFFECT THE TRAFFIC. THE CONNECTION TO THE SELECTED PASOLINK WILL BE LOST FOR FEW MINUTES AND WILL BE RECONNECTED AUTOMATICALLY. WARNING MAKE SURE THAT THE CORRECT PROGRAM FILE IS DOWNLOADED TO THE CTRL. INCORRECT PROGRAM FILE WILL LEAD TO CTRL FAILURE. DOWNLOAD PROGRESS IS INDICATED HERE

CLICK EXECUTE BUTTON TO RESET THE CPU

PNMT

51

UPLOAD CONFIGURATION FILE


[CTRL WINDOW] THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM THE CTRL OF THE SELECTED NE TO THE PNMT PC.

WHEN EQUIPMENT IS CONFIGURED (AUXILIARY ALARMS, BER THRESHOLD ETC.) TAKE A UPLOAD OF THE EQUIPMENT CONFIGURATION FILE TO THE PNMT PC.

CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (CTRL>>PC) TO OPEN THE UPLOAD CONFIGURATION FILE WINDOW.

WHEN THE PASOLINK IDU FOR A SITE IS REPLACED FOR SOME REASON THE EQUIPMENT CONFIGURATION FILE CAN BE DOWN LOADED TO CONFIGURE THE REPLACED IDU.

SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE WINDOW., MIB CONFIG OR NETWORK CONFIG. ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF NECESSARY. CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION, AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED.. AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW. AFTER DOWN LOADING, CARRY OUT THE UPDATE OPERATION

PNMT

52

EVENT & PERFORMANCE DATA

Latest 1
Event Log File Day 1 20020911

Oldest 300

EVENT LOG AND PERFORMANCE DATA ARE UPLOADED TO THE PNMT EACH TIME EVENT LOG AND PERFORMANCE MONITOR ARE SELECTED.

Day #1

Events Status Change Alarm Occurrence Alarm Recovery Controls Parameter Change

Link Performance ES SES UAS BBE OFS

IDU (PM Card)


Day #7

PNMT

53

EVENT LOG
NE SPECIFIC MENU BAR A MESSAGE WINDOW SHOWS THE PROGRESS OF THE UPLOAD

CLICK ON THE EVEN LOG IN THE NE SPECIFIC MENU BAR TO UPLOAD THE EVEN LOG ITEMS FROM THE SELECTED NE. EVENT LOG VIEW WINDOW SHOWS ALARM EVENTS, COMMAND EVENTS AND STATUS CHANGES. DIFFERENT COLORS SHOWS THE TYPE OF EVENT. EVENT LOG IS PRESENTED IN A TABLE FORM SHOWING THE DATE OF THE EVENT , THE ITEM THAT TRIGGERED THE EVENT AND THE STATUS CHANGE.

CLICK FILE-UPLOAD TO REFRESH THE EVENT LOG DISPLAY CLICK FILE-SAVE AS TO SAVE THE EVENT LOG TO CLICK FILE-PRINT TO PRINT THE EVENT LOG INFORMATION

PNMT

54

LINK PERFORMANCE MONITOR


NE SPECIFIC MENU BAR THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED ACCORDING TO THE G.826 RECOMMENDATIONS. OFS ES SES UAS BBE OUT OF FRAME SECONDS ERROR SECONDS SEVERELY ERROR SECONDS UNAVAILABLE SECONDS BACKGROUND BLOCK ERRORS CLICK ON THE LINK PERFORMANCE MONITOR IN THE NE SPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF THE PASOLINK TO BE MONITORED.

CURRENT BER VALUE IS SHOWN IN THIS FIELD THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES CAN BE SET IN THRESHOLD WINDOW.

THRESHOLD VALUE SETTING CLICK THE THRESHOLD BUTTON TO OPEN THE THRESHOLD SETTING WINDOW. SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN THE ALARM RECOVER IN THE APPROPRIATE FIELD.

AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO ACTIVATE THE NEW SETTING.
CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..

PNMT

55

LINK PERFORMANCE MONITOR


Link Performance Monitor (1day / 15 min. Data) window To view the 1day Data: 1. Click [Detail] button in Summary Link Performance Monitor window.

To view the 15-min. Data: 2. Click button of the target date in Link Performance Monitor (Daily Data) window to display the detailed 15-minute performance data.

PNMT

56

VERSION WINDOW
CLICK THE VERSION TAB TO DISPLAY THE VERSION INFORMATION WINDOW FOR THE SELECTED NE.

VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE , SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED NETWORK ELEMENT.

PNMT

57

Das könnte Ihnen auch gefallen