Sie sind auf Seite 1von 20

WELCOME

A SEMINAR PRESENTATION ON

MAGNETO HYDRO DYNAMICS (MHD) SYSTEM

Contents
1. 2. 3. 4. 5.

6.
7.

8. 9. 10. 11.

Introduction Need of MHDs Principle Of MHD Power Generation Types of MHD SYSTEM Open Cycle MHD System Closed Cycle MHD System Diffrence between Open Cycle and Closed Cycle MHD System Advantages OF MHD System Disadvantages of MHD System Applications Conclusion

Introduction
Magneto HydroDynamic (MHD) system is a nonconventional source of energy which is based upon Faradays Law of Electromagnetic Induction, which states that energy is generated due to the movement of an electric conductor inside a magnetic field.

Concept given by Michael Faraday in 1832 for the first time.

MHD System widely used in advanced

countries.
Under construction in INDIA.

Need of MHDs
At present a plenty of energy is needed to sustain industrial and agricultural production, and the existing conventional energy sources like coal, oil, uranium etc are not adequate to meet the ever increasing energy demands. Consequently, efforts have been made for harnessing energy from several nonconventional energy sources like Magneto Hydro Dynamics(MHD) System.

Faradays law of electromagnetic induction : When an electric conductor moves across a magnetic field, an emf is induced in it, which produces an electric current .

Principle Of MHD Power Generation

Lorentz Force
F = q(v B)

on the charged particle (vector),

where, v = velocity of the particle (vector) q= charge of the particle (scalar) B = magnetic field (vector)

Comparison between a Turbo generator and a MHD generator

Types of MHD SYSTEM


(1)Open cycle System (2)Closed cycle System (i)Seeded inert gas systems (ii) Liquid metal systems

OPEN CYCLE MHD SYSTEM

HYBRID MHD STEAM PART OPEN CYCLE

CLOSED CYCLE MHD SYSTEM

DIFFERENCE BETWEEN OPEN CYCLE AND CLOSED CYCLE SYSTEM


Open Cycle System

Closed Cycle System

Working fluid after generating electrical energy is discharged to the atmosphere through a stack . Operation of MHD generator is done directly on combustion products . Temperature requirement : 2300C to 2700C. More developed.

Working fluid is recycled to the heat sources and thus is used again. Helium or argon(with cesium seeding) is used as the working fluid. Temperature requirement : about 530C. Less developed.

NEED FOR FURTHER RESEARCH

The MHD channel operates on extreme conditions of temperature, magnetic and electric fields . So, numerous technological advancements are needed prior to commercialization of MHD systems . Search is on for better insulator and electrode materials which can with stand the electrical, thermal, mechanical and thermo-chemical stresses and corrosion.

ADVANTAGES OF MHD SYSTEM

Conversion efficiency of about 50% . Less fuel consumption. Large amount of pollution free power generated . Ability to reach full power level as soon as started. Plant size is considerably smaller than conventional fossil fuel plants . Less overall generation cost. No moving parts, so more reliable .

DISADVANTAGES OF MHD SYSTEM


Suffers from reverse flow (short circuits) of electrons through the conducting fluids around the ends of the magnetic field. Needs very large magnets and this is a major expense. High friction and heat transfer losses. High operating temperature. Coal used as fuel poses problem of molten ash which may short circuit the electrodes. Hence, oil or natural gas are much better fuels for MHDs. Restriction on use of fuel makes the operation more expensive.

APPLICATIONS

Power generation in space craft.

Hypersonic wind tunnel experiments.


Defense application.

CONCLUSION
The MHD power generation is in advanced stage today and closer to commercial utilization. Significant progress has been made in development of all critical components and sub system technologies. Coal burning MHD combined steam power plant promises significant economic and environmental advantages compared to other coal burning power generation technologies. It will not be long before the technological problem of MHD systems will be overcame and MHD system would transform itself from non- conventional to conventional energy sources.

THANK YOU !!

Das könnte Ihnen auch gefallen