Beruflich Dokumente
Kultur Dokumente
BOOBALAN A (2011208031)
1
2
PRELIMINARY TEST
CUBE CASTING(M25 GRADE10%,20%,40%,50%-FLY ASH REPLACEMENT)
REQUIRED DATA: M-25 Grade concrete-10% fly ash replacement. Uncrushed aggregates (20mm) F.A. shows that 40% passes through 600micron sieve. Slump ranges taken as 30-60mm. Concrete to be prepared at moderate condition. Reinforcement cover adopted as 25mm.
ash
water
S.NO
NO OF DAYS
1 2
7 28
15 15
56
15
15
15
Compressive
Strength To determine the compressive strength of concrete specimens as per IS: 516 - 1959. Tests should be done at recognized ages of the test specimens, usually being 7 and 28 days. The ages should be calculated from the time of the addition of water to the drying of ingredients
S.No
1 2 3
S.No
No of days
10%
20%
40%
50%
13.05
13.57
13.30
13.13
28
26.90
26.51
25.20
26.12
1.A. Fernandez-Jimenez I. Garca-Lodeiro A. Palomo (2006), Eduardo Torroja Institute (CSIC), Serrano Galvache St., 28080 Madrid, Spain- Durability of alkali-activated fly ash cementitious materials, P.No (30553065).
2.C.S. Poon, L. Lam, Y.L. Wong (1999), Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hung Him, Hong Kong, People's Republic of China - A study on high strength concrete prepared with large volumes of low calcium fly ash, P. No(447-455).
C.Y. Lee, H.K. Lee, K.M. Lee (2002), Conclinic Co. Ltd., Seoul, South Korea ,Department of Civil and Environmental Engineering, Sungkyunkwan University- Strength and micro structural characteristics of chemically activated fly ash cement systems, P.No(425431). 4. Bashar S. Mohammed* and Ong Chuan Fang (2010),Department of Civil Engineering, College of Engineering, University Malaysia.-Assessing the properties of freshly mixed concrete containing paper-mill residuals and class F fly ash , Vol. 2(2), P.no (17-26).
THANK YOU