Power Routes for BTS Site

E.L.C.B 63A

Mains (WAPDA 03 )

ATS
Generator (03 )

D I S T R I B U T I O N P A N E L

10A, 2P

In/Out door Lights

10A, 2P

Tower Lights
Emergency Lights
RF Antenna

10A, 2P

10A, 2P

Fire Device
E.L.C.B. 25A Sockets

M/W Antenna

16A, 2P

32A, 2P

ACs Spares Rectifier

BTS Cabinet

Microwave IDU

10A/32A 2P (each) 32A, 4P (AC Supply)

DC Supply -54V

(D.P)

Batter y Backu p

LVD

CONTENTS
Introduction Identify Cables Routs Installation and Wiring Functional Testing Adjustments

Maintenance and Component Replacement

Introduction to GEDP

External View

Internal View

Label Your Circuit Breaker Box to End Confusion

D.P

ATS

PM with

good manners.

Cable Glands

Ducting for Power Cables

Earth Strip

GEDP Components

Volt Meter

GEDP Selection Switch Rela y 24h Timer

Terminal Block Door Lock Magnetic Contactors

Circuit Breaker

Terminal Block

Fus es

Indicator

Thermostat

Cables & Accessories

I-Type Terminal

Photo Sw

Energy Saver

AC/Female Terminal

Lightning Current Arrestor

O-Type Terminal

16 mm Terminal Lug

Power Cables

U-Type Terminal

Circuit Breaker

Choosing the correct size cable


S.No 1 2 3 4 5 6 7 Size (mm) 1 1.5 2.5 4 6 10 16 Similar Size 1/44 3/29 7/29 7/36 7/44 7/52 7/64 Max (AMP) 8 13 20 25 32 40 100

The wire has to be the correct size so that it can cope with the power demands of the device. If a cable used which is too small for the amount of current passing through, it becomes dangerous. This results in the wire overheating and causing a serious safety risk.

Color Identification of Cores of Cables

Tools

Crimping Tool

Long Nose Plier

Krone Puncher

Screw Drivers

Common Plier

Cable Cutter

CB Order Information

S25 1S C10

Type/Size Pole

Rated Current

17.5 mm

2 Pole

3 Pole

4 Pole

Different Circuit Breakers


MCB E.L.C.B MCP PCB RCCB MCCB Main Circuit Breaker (Mini CB, Miniature CB) Earth Leakage Circuit Breaker Motor Circuit Protector Power Circuit Breaker Residual Current Circuit Breaker Molded Case Circuit Breaker

Available CBs in Normal Distribution Panel


E.L.C.B M.C.B Rectifier C.B ACs C.Bs Lights C.B Sockets C.Bs ELCB (Sockets) Fire Panel C.B Beacon Lights C.B Two spare C.Bs (63A, 4P) (63A, 4P) (32A, 4P) (32A, 2P) (10A, 2P) (16A, 2P) (25A, 2P) (10A, 2P) (10A, 2P) (10A, 2P & 32A, 2P)

Magnetic Contactor Order Information

A9-30-10-84

Size Power pole 30 = 3 NO 40 = 4 NO 22 = 2 NO & 2 NC

Coil voltage (see coil voltage selection chart)


Auxiliary contacts

10 = 1 NO & 0 NC 01 = 0 NO & 1 NC 11 = 1 NO & 1 NC 00 = No auxiliary provided

Coil voltage selection chart


Hz 50 60 12 24 81 81 48 83 83 110 120 125 208 220 240 277 380 415 440 480 500 600 84 84 84 34 36 80 80 42 85 86 86 86 51 53 55 55

24h ACs Timer & Thermostat (Honeywell)

3 NC

4 NO

1 COMM

Thermostat (Honeywell) Connections

1 & 3 = H.T Sensor (with DDF) 1 & 4 = 27 Sensor (with 24h ACs Timer)

DDF for Site External Alarms

Alarms Patching for Motorola BTS Site

BTS Cable Color Codes for DDF


Number
1 2 3 4 5 6 7 8

Alarm Indication
GENSET DC-DC CONVERTER TEMPERATURE LOW VOLTAGE INTRUDER RECTIFIER MAJOR FIRE RECTIFIER MINOR

Cable Color codes


WHITE / BLUE BLUE / WHITE WHITE / ORANGE ORANGE / WHITE WHITE / GREEN GREEN / WHITE WHITE / BROWN BROWN / WHITE GREY / RED BLACK / BLUE BLUE / BLACK BLACK / ORANGE ORANGE / BLACK BLACK / GREEN GREEN / BLACK BLACK / BROWN

Thank You