Beruflich Dokumente
Kultur Dokumente
This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage
Respirator Inspection
Before each use: Make sure you have the right respirator for the job
Inspect it for wear and damage.
Inspection Points
Check for worn or frayed Straps & Hoses. Look for wear or damage on the seal of the facepiece.
Also Check
Be
Check
And Check
Valves should be clean and seated perfectly. Check for cracks or deformities in the face shield.
Check condition of filters, cartridges or canisters. Damage to speaking diaphragm, if there is one.
Ensure you have the correct Filters & Cartridges for the job
NOTE: Color codes on cartridges & filters are only a guide. Read the label to be sure you have the right kind. If a combination of elements is required check to ensure you have the right combination on each side of the respirator.
Check
air supply pressure low pressure alarms
regulator by-pass
hoses for damage or
Close off the exhalation valve and exhale gently into the facepiece. The face fit is considered satisfactory if a slight positive pressure can be built up inside the facepiece without any evidence of outward leakage of air at the seal. For most respirators, this method of leak testing requires the wearer to first remove the exhalation valve cover before closing off the exhalation valve, and then carefully replacing it after the test.
Close off the inlet opening of the canister or cartridge(s) by covering it with the palm of the hand(s) or by replacing the filter seal(s).
Inhale gently so that the facepiece collapses slightly, and hold your breath for ten seconds.
Safety Note:
The design of some cartridges may require the test be performed by covering the inlet opening of the cartridge with a thin latex or nitrile glove to effectively seal the inlet.
If the facepiece remains in its slightly collapsed condition, and no inward leakage of air is detected, the tightness of the respirator is considered satisfactory.
Manufacturer's Procedures
The respirator manufacturer's recommended procedures for performing a user seal check may be used instead of the positive and/or negative pressure check procedures, provided that they are equally effective in detecting seal leakage compared to the positive pressure and negative pressure checks previously described.
Respirator Cleaning
Remove and clean filters, cartridges, valve assemblies and any other detachable parts.
As you clean and dry each part of the respirator, inspect carefully to be sure it is in good condition.
Basic Procedure
Make sure flexible parts are still flexible, and check the stretch of elastic bands.
Generally, a mild detergent and a soft brush are used for cleaning.
Thoroughly in clean, warm water. Rinsing is extremely important because a residue of the cleaning agent can damage the respirator and irritate skin. Be sure all parts are thoroughly dry before putting the respirator back together again. Use a soft, lint-free cloth to absorb most of the water and a fan to speed up the drying process.
Disassemble Respirator
Wash components in warm (43C/110F maximum) water with a mild detergent or with a cleaner recommended by the manufacturer.
A soft bristle (not wire) brush may be used to facilitate the removal of dirt.
Rinse components thoroughly in clean, warm (43C/110F maximum), preferably running, water.
Drain the parts to remove excess water.
When the cleaner used does not contain a disinfecting agent, respirator components should be immersed for two minutes in Hypochlorite solution (50 ppm of chlorine) made by adding approximately one milliliter of laundry bleach to one liter of water at 43C/110F
Or Use
Liquid solution of iodine (50 ppm iodine) made by adding approximately 0.8 milliliters of tincture of iodine (6-8 grams ammonium and/or potassium iodine/100 cc of 45% alcohol) to one liter of water at 43C/110F
Other commercially available cleansers of equivalent disinfectant quality when used as directed, if their use is recommended or approved by the respirator manufacturer.
Rinse components thoroughly in clean, warm (43C/110F maximum), preferably running, water.
The importance of thorough rinsing cannot be overemphasized. Detergents or disinfectants that dry on facepieces may result in dermatitis.
Disinfectant Note
In addition, some disinfectants may cause deterioration of rubber or corrosion of metal parts if not completely removed.
Respirator Storage
Store your respirator where it will be protected. Protect the respirator from dust, sunlight, extreme heat and cold, moisture, damaging chemicals and physical damage.
YOUR respirator
The respirator you use is designed to protect your health and life but only if you use, clean and store it properly