Sie sind auf Seite 1von 24

Networking and VLANs

Copyright Alvarion Ltd.

Objectives

Upon completion of this module students will know the following:

Understand and use services features for networking Create and configure services that support advanced VLAN topology

Ver. 09-04-15

BreezMax tagging

The BreezeMAX provides high flexibility regarding VLANs Packets can be tagged and untagged within the system

Untagging/Tagging by BS

Untagging/Tagging by SU switch

Ver. 09-04-15

Service Profile parameters VPL ID


LA

Available values 0 to 4094 or null (empty string) for No VPL ID A value of 4095 is displayed for No VPL ID Service profiles can share the same VPL number but:

VPL ID = Null
VLAN 4095

Switc h

NO VPL ID
L

LA

VPL ID = 301
VLAN ID 101

Switc h

All Must have the same

Forwarding rule

VPL ID 301

LA

VPL ID = 301
Untagged

Switc h

VPL ID 301
Ver. 09-04-15

VPL ID NONE

Outbound
UT

Internet

UT

4095

100
Ver. 09-04-15

VPL ID NONE

Inbound

Internet

UT 100 UT

4095

100

Ver. 09-04-15

Service Profile parameters VLAN Transparency Mode


Used for VLAN consistency VLAN Transparency Mode values (ON/OFF)


LA

Enabled (ON)

The VLAN ID on both sides of the BS


( wireless , backbone) is the same

Transparency mode ON
VLAN ID 101

Switch

The VPL ID parameter is not


applicable

Forwarding rule is set automatically


as @@Transparent@@

VLAN ID 101

Only one service on each SU (If there


are several services within the same SU) can be set with VLAN Transparency Mode = ON Note: When using VLAN transparency mode ON, verify that the VLAN tags in the list of the transparent service are different than any VPL ID of other services.
Ver. 09-04-15

Service Profile parameters VLAN Transparency Mode

Disabled (OFF)

The VPL ID Must be assigned to

the service (none is also a valid value)

LA

Transparency mode OFF


VLAN ID 101

Switch

VPL ID 23

Ver. 09-04-15

Access VLAN

It is also mandatory to set Transparent Mode to ON

Enables to set that the SU tags any untagged frames arrives from the Ethernet port and vice versa
When Access VLAN is set with a VLAN ID, the feature is set to ON Ethernet side Backbone side
5 10

VLAN ID 5
5

Packet VLAN ID Packet VLAN ID


5 10

5 Untagged

UT

Untagged

Access VLAN = 10

Hybrid Mode
Hybrid Mode

10

VLAN List

Description
Only tagged packets with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 16 entries Forwards all packets (both untagged and tagged with any VLAN ID) Untagged packets, and packets tagged with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 15 entries Only untagged frames are forwarded

Filled OFF Empty Filled ON

VLAN ID 5
VLAN list
VLAN 3

Empty

VLAN ID 3

untagged

Hybrid Mode
Hybrid Mode VLAN List Filled OFF Empty

11

Description
Only tagged packets with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 16 entries Forwards all packets (both untagged and tagged with any VLAN ID) Untagged packets, and packets tagged with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 15 entries Only untagged frames are forwarded

VLAN ID 5
ON

Filled
Empty

VLAN list

VLAN ID 3

untagged

Hybrid Mode
Hybrid Mode VLAN List Filled OFF Empty

12

Description
Only tagged packets with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 16 entries Forwards all packets (both untagged and tagged with any VLAN ID) Untagged packets, and packets tagged with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 15 entries Only untagged frames are forwarded

VLAN ID 5
ON

Filled
Empty

VLAN list VLAN 3

VLAN ID 3

Untagged

Hybrid Mode
Hybrid Mode VLAN List Filled OFF Empty

13

Description
Only tagged packets with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 16 entries Forwards all packets (both untagged and tagged with any VLAN ID) Untagged packets, and packets tagged with a VLAN ID that exists in the VLAN List are forwarded VLAN List can include up to 15 entries Only untagged frames are forwarded

VLAN ID 5
ON

Filled
Empty

VLAN list

VLAN ID 3

Untagged

VLAN Classification Mode

14

In case R1 doesn't support any priority marking

Services defined with transparent mode set ON Each service contains ONLY one VLAN ID

VLAN Classification is set to ON

In the downlink direction the BS classifies the service by the VLAN ID instead of the priority tag For using more than one VLANS with one MAC address
SU1 R1

VLAN ID = 2 VLAN ID = 5

BS

VLAN ID = 2 VLAN ID = 5
SU2

VLAN ID = 5 VLAN ID = 2 VLAN ID = 5

R2 B Hybrid Mode OFF

Subscriber (owner) Square Co.

VLAN 2 (Phone), 5 (A,B) VPL ID Transp mode ON

SU MAC SU 1

Service VLAN Access Profile Classification VLAN ALPHA ON OFF

Service 2nd st. SQUARE Co.

Service Profile ALPHA

FWD rule
@@Transparent@@

Priority classifier group #2

Marking Mode 802.1p 5

Ver. 09-04-15

VLAN Tagging

15

Case I
Internet

Case II
B SU1 SW C D F BS SU2 SW G SU2 SW G R D
Internet

B SU1 SW C F

BS

Case III Stations associated to VLAN


Internet

B SU1 SW C D F

Station not associated with any VLAN, that can be connected Station not associated with any VLAN, that can not be connected

BS SU2 SW G

VLAN Tagging
BS to Backbone SU to BS Switch to SU

16

Backbone to BS

BS to SU

SU to Switch

The following slides explains the way a frame is tagged (VLAN tag) in three points of the system

SU network port

SU wireless port (Uplink direction) / BS Wireless port (Downlink direction)


BS Network port

VLAN Tagging

17

Case I
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 4 2 B (VLAN1) 3 1 OFF G (no VLAN) OFF OFF H (VLAN1) C (no VLAN) D (VLAN2) F (VLAN3) for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking switch to SU (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 SU to BS (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 BS to Backbone (VPL) VPL10 NA VPL2 VPL3 NA VPL1 -

Downlink (DL) VLAN / VPL marking backbone to BS (VPL) VPL10 NA VPL2 VPL3 NA VPL1 VPL10 BS to SU (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1 SU to Switch (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1

Broadcast
OFF

VPL2
VPL3

VLAN2
VLAN3

VLAN2
VLAN3

VLAN Tagging

18

Case II a
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 2 1 B (VLAN1) 1 2 OFF G (no VLAN) OFF OFF OFF H (VLAN1) Broadcast C (no VLAN) D (VLAN2) F (VLAN3) for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking

Downlink (DL) VLAN / VPL marking

switch to SU (VLAN)
VLAN1 NA VLAN2 VLAN3 NA VLAN1 -

SU to BS (VLAN)
VLAN1 NA VLAN2 VLAN3 NA VLAN1 -

BS to Backbone (VPL)
VPL1 NA VPL1 VPL1 NA VPL1 -

backbone to BS (VPL)
VPL1 NA VPL1 VPL1 NA VPL1 VPL1

BS to SU (VLAN)
VLAN1 NA VLAN2 VLAN3 NA VLAN1 =VPL1 (same as VPL1)

SU to Switch (VLAN)
VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1 VLAN2 VLAN3

VLAN Tagging

19

Case II b
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 2 1 B (VLAN1) 3 ON G (no VLAN) OFF OFF Broadcast OFF H (VLAN1) C (no VLAN) D (VLAN2) F (VLAN3) for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking switch to SU (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 SU to BS (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 BS to Backbone (VPL) VLAN1 NA VLAN2 VLAN3 NA VLAN1 -

Downlink (DL) VLAN / VPL marking backbone to BS (VPL) VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1 BS to SU (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1 SU to Switch (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1

VLAN2
VLAN3

VLAN2
VLAN3

VLAN2
VLAN3

VLAN Tagging

20

Case II c
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 2 2 B (VLAN1) 2 2 OFF G (no VLAN) OFF OFF Broadcast OFF H (VLAN1) C (no VLAN) D (VLAN2) F (VLAN3) for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking switch to SU (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 SU to BS (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 BS to Backbone (VPL) VPL1 NA VPL1 VPL2 NA VPL2 -

Downlink (DL) VLAN / VPL marking backbone to BS (VPL) VPL1 NA VPL1 VPL2 NA VPL2 VPL1 VPL2 BS to SU (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 =VPL1
(same as VPL1)

SU to Switch (VLAN) VLAN1 NA VLAN2 VLAN3 NA VLAN1 VLAN1 VLAN2 VLAN1 VLAN3

=VPL2
(same as VPL2)

VLAN Tagging

21

Case III a
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 2 1 B (VLAN1) 1 2+1 OFF G (no VLAN) ON OFF Broadcast OFF H (VLAN1) C (no VLAN) D (VLAN2) F (VLAN3) for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking switch to SU (VLAN) VLAN1 no VLAN VLAN2 VLAN3 no VLAN VLAN1 SU to BS (VLAN) VLAN1 VLAN4095 VLAN2 VLAN3 VLAN4095 VLAN1 BS to Backbone (VPL) VPL1 VPL1 VPL1 VPL1 VPL1 VPL1

Downlink (DL) VLAN / VPL marking backbone to BS (VPL) VPL1 VPL1 VPL1 VPL1 VPL1 VPL1 BS to SU (VLAN) VLAN1 VLAN4095 VLAN2 VLAN3 VLAN4095 VLAN1 =VPL1 SU to Switch (VLAN) VLAN1 no VLAN VLAN2 VLAN3 no VLAN VLAN1 VLAN1 VLAN2 VLAN3 no VLAN

VPL1

(same as VPL1)

VLAN Tagging

22

Case III b
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 2 1 B (VLAN1) 3+1 ON ON OFF OFF Broadcast for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking switch to SU (VLAN) VLAN1 SU to BS (VLAN) VLAN1 BS to Backbone (VPL) VLAN1

Downlink (DL) VLAN / VPL marking backbone to BS (VPL) VLAN1 BS to SU (VLAN) VLAN1 SU to Switch (VLAN) VLAN1

C (no VLAN)
D (VLAN2) F (VLAN3) G (no VLAN) H (VLAN1)

no VLAN
VLAN2 VLAN3 no VLAN VLAN1 -

VLAN4095
VLAN2 VLAN3 VLAN4095 VLAN1 -

no VLAN
VLAN2 VLAN3 no VLAN VLAN1 -

no VLAN
VLAN2 VLAN3 no VLAN VLAN1 VLAN1 no VLAN

VLAN4095
VLAN2 VLAN3 VLAN4095 VLAN1 VLAN1 VLAN4095

no VLAN
VLAN2 VLAN3 no VLAN VLAN1 VLAN1 no VLAN

VLAN2
VLAN3

VLAN2
VLAN3

VLAN2
VLAN3

VLAN Tagging

23

Case III b
Total Nr. of Services Total Nr. of SPFs Total Nr. of VPLs Nr. of VLANs (per Service) Transparency Mode Hybrid Mode VLAN Classification Access VLAN 2 1 B (VLAN1) 3+1 ON ON OFF 4 Broadcast for UL: SA for DL: DA

Uplink (UL) VLAN / VPL marking switch to SU (VLAN) VLAN1 SU to BS (VLAN) VLAN1 BS to Backbone (VPL) VLAN1

Downlink (DL) VLAN / VPL marking backbone to BS (VPL) VLAN1 BS to SU (VLAN) VLAN1 SU to Switch (VLAN) VLAN1

C (no VLAN)
D (VLAN2) F (VLAN3) G (no VLAN) H (VLAN1)

no VLAN
VLAN2 VLAN3 no VLAN VLAN1 -

VLAN4
VLAN2 VLAN3 VLAN4 VLAN1 -

VLAN4
VLAN2 VLAN3 VLAN4 VLAN1 -

VLAN4
VLAN2 VLAN3 VLAN4 VLAN1 VLAN1 VLAN4

VLAN4
VLAN2 VLAN3 VLAN4 VLAN1 VLAN1 VLAN4

no VLAN
VLAN2 VLAN3 no VLAN VLAN1 VLAN1 no VLAN

VLAN2
VLAN3

VLAN2
VLAN3

VLAN2
VLAN3

Thank You

Das könnte Ihnen auch gefallen