Sie sind auf Seite 1von 20

SANKOM C.H. version 3.

GRAPHICAL PROGRAM FOR DESIGNING AND HYDRONIC BALANCING OF CENTRAL HEATING INSTALLATION

General program features


Graphical designing of new central heating installations. Hydronic balancing of already existing central heating installations. Designing systems of pipes in ice-water installations. Graphical designing of underfloor heating installations.

Central heating installation criteria


Pump installation . Two-pipe system . Upper- or bottom division, vertical pipes distribution systems, manifold systems . Convection or Underfloor radiators . Automatic air bleeders (no de-aerating grid present) .

Normal or thermostatic radiator valves .


Initial regulation by valves with initial preset or orifices . Differential pressure balancing by balancing stabilisers . Possibility of using flow governors .

Hydraulic calculations
Adjustment of diameters of pipes. Estimation of hydraulic resistance for individual circuits, taking into account gravity pressure, resulting from water cooling in pipes and heat receivers.

Reduces overpressure in circuits by adjusting initial presets of valves with double control, or adjustment of aperture diameters for balancing orifices.
Takes into account necessity of ensuring the relevant hydraulic resistance of pipe-run with heat receiver (pgmin).

Adjustment of presets for differential pressure governors installed in positions selected by designer (risers base, installations branch, etc.).
Adjustment of presets for differential pressure governors installed in positions selected by designer (risers base, installations branch, etc.).

Automatically takes into account requirements on authorities for thermostatic valves (appropriate pressure drop on valves).

Heat calculations
Estimation of heat gains from pipes of installation led in individual rooms. Calculation of cooling for heating agent in pipes . Estimation of required radiators dimensions for given heat load demand. Adjustment appropriate flux of heating agent inflowing heat receivers, taking into account its cooling in pipes and heat gains from pipes (variant of regulation of existing installation, e.g. in additionally insulated buildings). Takes into account influence of water cooling in pipes on value of gravity pressure in individual circuits, as well as on heat load of heat receivers. Designs underfloor radiators

Basic data
Includes basic data for whole installation. Dedicated for the calculation range selection.
Catalogue data

Calculation variant selection Water temperatures

Heat surce parameters

Available pipes

Drawing of the installation diagram


Data are to be entered in graphic form into installation diagram.
Radson OZC

Pull-down list configuration

Movable tool bars

Pull-down buttons

Two independently scaled views of the drawing

Drawing functions tool bar Dynamic link of the table and the drawing

Tables enabling simultaneous editing of many components of the installation

Categories Drawings for items present being edited in the project

Preparing the installation diagram example


Plate radiators
Radson OZC

Room Pipes tab Ceiling zones Radiators Accessories Construction tab Creation 1 tab tab Pokj +20C 1976/0 W Scale selection
1/2 1/3 dn A dn A

Labels
2 Kuchnia +20C 429/0 W

dn A

1/4

V-EXAKT-DT dn

V-EXAKT-DT dn

100 % KOMPAKT-**60 0m

100 %
KOMPAKT-**60 0m

+ 3.00

Use of the ready blocks


Copy to the Traditional Copy to the Up instalations Radson OZC Right

+ 6.00
101 Pokj +20C 1109/0 W

Copying and Blocks 103 tab W.C.


1 Pokj % +20C 100 1976/0 W
dn A 1/104 V-EXAKT-DT dn 1/101

102 azienka +25C 507/0 W

Automatically renumbered rooms


+ 6.00

+20C 0/0dn W A
dn A

104 ReadyPokj blocks +20C 554/0 W dn A


2/103 dn A V-EXAKT-DT dn

103 W.C. +20C 0/0 W

104 Pokj +20C 554/0 W

1/103

V-EXAKT-DT dn

100 % 0m

100 %

2 Automatically Kuchnia 100 % renumbered +20C 429/0 W


dn A 2/104 V-EXAKT-DT dn

2/102

0m

dn A

0m

dn A
2/104

2/102 dn A
3 W.C. +20C 110/0 W

1/2 dn A

0m

pipe-runs

1 Pokj +20C 1976/0 W


dn A

2/103

dn A

1/3

dn A

1/3

V-EXAKT-DT V-EXAKT-DT dn A 1/2 dn dn dn A


1/4

2 Kuchnia +20C 429/0 W

V-EXAKT-DT dn dn A
2/3

V-EXAKT-DT dn A 2/2 dn dn A
2/4

4 Sie +16C 218/0 W

1/4

V-EXAKT-DT dn

100 % 0m

100 %

V-EXAKT-DT dn

V-EXAKT-DT dn

100 % 0m

100 %
V-EXAKT-DT dn

100 % 0m

+ 3.00

+ 3.00

C**-60 0m 0m

100 %

100 % 0m

C**-60 0m 0m

100 %

The horizontal apartment system


4 Kuchnia +20C 700 W
KL Klatka +16C 0 W
EEM-VM-1 dn 15

6 Pokj +20C 1500 W


103 Pokj +20C 1000 W 104 Kuchnia +20C 700 W 105 azienka +25C 500 W
RTD-K dn 15 n 3

500 W C11-60 0.5 m

1 Po +20C

2/101

2/103

2/104

2/106

2/107

2/109

2/110

5 C11-60 Block 0.9 m azienka valves +25C 500 W


dn 18 dn 15
KOMBI-3+ -N dn 15 n 5

1000 W

700 W C11-60 0.6 m

C11-60 0.5 m
dn 12

dn 18

dn 18

dn 12

dn 15

V2000-D-V dn 10 n 2.4

Drawino of 700 W Tables


C11-60 0.6 m
dn 15 2/20

2/10

2/12

2/6

2/7

dn 12

dn 18

dn 12

2/9

3 Pokj +20C 1000 W

4 Kuchnia +20C 700 W

V2000-D-V dn 10 n 7

dn 15 dn 15 2/12

2/112

RTD-K V2000-D-V dn 10 n 3 dn 15 n3

500 W

V2000-D-V dn 10 n 2.25

Po

+20C 1500 W

dn 15

dn 15

RTD-K dn 15 n 3

500 W C11-60 0.5 m

C11-60 1.8 m

5 azienka +25C 500 W


V2000-D-V dn 10 n 3 V2000-D-V dn 10 n 2.4

EEM-VM-1 dn 15

2/1

2/3

2/4

2/6

2/7

dn 18

dn 15

dn 18

dn 12

dn 18

dn 12

2/9

1000 W C11-60 0.9 m

700 W C11-60 0.6 m

Radson C.O.

Przykadowy projekt instalacji C.O.


KOMBI-3+ -N dn 15 n 3.6 dn 20

R/1

PIW Piwnica +5C 0 W

Przykad 2 Adres:

Radson C.O.

Przykadowy projekt insta

Warszawa, ul. Nowowiejska 20 Przykad 2


Adres:

Projektowa: mgr in. P. Wereszczyski Ry Projektowa: mgr in. P. Wereszczysk

Warszawa, ul. Nowowiejs

dn 15

2/10

+20C 1000/0 W

+20C 700/0 W

+25C 500/0 W 500 W


VKO11-60 0.5 m
n2

+20C 1000/0 W
ASV-I dn 15 n 1.2 ASV-I dn 15 n 1
R/1

dn 16 A 1/P202 Q 1000

dn 16 A 1/P203 Q 700

dn 16 A 1/P204 Q 500

0W

700 W C11-60 0.6 m

1000 W C11-60 1m

-60 m

102 Pokj +20C 1000/0 W

103 Kuchnia +20C 700/0 W

dn 16 A 1/P102 Q 1000

dn 16 A 1/P103 Q 700

dn 16 A 1/P104 Q 500

0W

700 W C11-60 0.6 m

1000 W C11-60 1m

-60 m

2 Pokj +20C 1000/0 W

3 Kuchnia +20C 700/0 W

4 azienka +25C 500/0 W 500 W


VKO11-60 0.5 m
n2

5 Pokj +20C 1000/0 W

dn 16 A 1/P002 Q 1000

dn 16 A 1/P003 Q 700

dn 16 A 1/P004 Q 500

0W

700 W C11-60 0.6 m

1000 W C11-60 1m

-60 m

dn 16 A 1/P005 Q 1000

RTD-N-P dn 15 n 4

RTD-N-P dn 15 n 3.5

RTD-N-P dn 15 n 4

dn 16 A 1/P105 Q 1000

RTD-N-P n 15 n 4.5

RTD-N-P dn 15 n 3.5

RTD-N-P dn 15 n 4.5

ASV-I dn 15 n 1

Radiatorsn 2 VKO11-60 INTEGRA 0.5 m

104 azienka +25C 500/0 W 500 W

105 Pokj +20C 1000/0 W

dn 16 A 1/P205 Q 1000

RTD-N-P dn 15 n 4

The manifold apartment system


RTD-N-P dn 15 n 3.5 RTD-N-P dn 15 n 4

d Q

ZP-PU dn 15

GP-TERAKOTA dn=17 Q=80 W Fc=0.9 Lc=5.8 B=0.15

dn 17 B

The underfloor radiators installation


ZT-PURMO dn 15

1/105

ZTd

GP-TERAKOTA dn=17 Q=1 Fc=2.4 Lc=22.5 B=0.1

Underfloor radiator

1 Pokj +20C 1728 W


ZP-PURMO dn 15 n 5

Wszystkie przewody izolowane p

ZP-PURMO dn 15 n 0

1/6

dn 17 B

-MARMUR dn=17 Q=259 W Fc=3.8 Lc=17.7 B=0.2

GP-MARMUR dn=17 Q=1123 W Fc=15.5 Lc=78.3 B=0.2 Fb=1.1 Lb=8.1 Bb=0.1

dn 17 B

ZT-PURMO dn 15

ZT-PURMO dn 15

1/5

ZT-PUR dn 15

GP-MARMUR dn=17 Q=346 W Fc=5.7 Lc=28.0 B=0.2 Fb=1.1 Lb=3.9 Bb=0.1


3

C11-60 0.7 m

dn 20 A

VF-3-2.5 dn 15

O3 Pracownia Mixing +20C 610 W module

R/7

dn 16 A

V-EXAKT-DT dn 10 n 3

VF-3-2.5 dn 15

610 W

Designing of the underfloor radiators


Flexible underfloor radiator construction definition. Creation of the underfloor radiators catalogue .
Layers above the pipes

Pipe-coil construction Layers below the pipes

Designing of the underfloor radiators


Preliminary calculations.
Calculations temperatures Unitary thermal efficiency Floor temperature

Pipes information's

Calculated pipe length and floor area


Hydraulic calculations results

Drawing on the plan views


Radson C.O.

Radiators Underfloor Room Instalation labels item Graphic Pipes radiators label tabViews tab

Entering then plan view drowing form file (wmf, dxf, dwg) or clipboard

Border zone

KOMPAKT-**-60

5
GP-MARMUR GP-MARMUR dn= dn= Fc=5.7 Fc=5.7 Lc= Lc= B=0.2 B=0.2 Fb=1.3 Fb=1.3 Lb= Lb= Bb= Bb=

Pokj +20C 723 W

dn A

2/5

The calculation results


Calculations results may be presented both in table- as in the graphic.
Radson C.O.

Setting layers visibility Results in the graphic form

Valve preset Font style selection Radiator value Line style size
Dynamic link of tables with the installation diagram

Layer editing Drawing layers formating

Results in the table form

The calculation results on the plan view


Radson C.O.

Underfloor radiators

Radiators (length scale is saved)

Described pipes

The calculation results presentation


The contents of all tables can be formatted (choice of rows and columns to be shown, choice of font size) and sorted according to freely chosen key . All drawings could be transferred in to another application using WMF, DXF and DWG format. In case of the DXF and DWG files the layers and blocks structure a saved. The contents of all tables can be transferred in to another application via clipboard.

Plotting of the calculations rusalts


Calculations results canformatting be plotted onto the plotter or printer . Plot preview Plot command
command Printer or plotter selection

Plotting scale

Plotting Margins

Plotting pagination

References
Poland
Aquatherm Comap Coprax Herz Honeywell IMI Oventrop Kan

Russia
Danfoss Honeywell IMI Kan Rettig (PURMO) Vogel & Noot

Czech Republic
Kan

Radson
Rettig (PURMO) UPONOR

Das könnte Ihnen auch gefallen