Sie sind auf Seite 1von 67

Huawei DBS3800 Hardware Installation

March, 2007
www.huawei.com

Page 1

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

HUAWEI TECHNOLOGIES CO., LTD.

Distributed NodeB Solution

Hardware Structure
Hardware Installation

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 2

Distributed NodeB Overview


The distributed NodeB system consists of:

BBU3806 RRU3801C
Antenna TMA RF jumper

Antenna and Feeder system


RRU 3801C
Feeder A&F system grounding cable RF jumper

RNC

-48V DC power

Power cable
BBU3806 Power cable Trunk cable

-48V DC power

Grounding cable
Fiber or CPRI high-speed signal cable

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 3

Distributed NodeB Solution

Hardware Structure
Hardware Installation

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 4

Distributed NodeB BBU3806


Indoor baseband unit BBU3806

19inch box, 1U Mechanical

Dimensions

42 x 436 x 300 mm (HxWxD)

Weight Power supply Max power consumption Temperature range

5 kg -48VDC

60W -5 to +55C

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 5

Distributed NodeB RRU3801C


Radio remote unit: RRU3801C

Mechanical Dimensions Weight Power supply Output power (TOC) Power consumption (40WPA) Temperature range /
Modularized

565 x 390 x 165 mm (HxWxD) 18 kg -48VDC 20W 240W

architecture enables

Environment environment relative humidity

-33 to 50C

easy maintenance and flexible

expansion

5%100%RH

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 6

BBU3806 Panel
Indicator Power Switch Power To DC_BOX Grounding

BITS

GPS

FE1 CPRI0 CPRI1 CPRI2

RUN ALM ACT

EXT_ALM

TX RX TX RX TX RX ESD E1/T1/J1 Ela Elb CPRI0 CPRI1 CPRI2


FE0

LIU0 LIU1 LIU2 LIU3 LIU4 LIU5 LIU6 LIU7

ON OFF OFF ON 8K/TT110M RST TYPE LOCAT_ID E1/T1/J1 ETH_RS232 PWR/RS485

BBU-RNC interface

Fiber

E1
To DDF

RRU 0

RRU

RRU

Only These two switch must be on.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 7

Distributed NodeB RRU3801C


1

1 1
Power To DC-BOX

2
PWR RET RX_IN/OUT ANT _ T X/RXA ANT _RXB

2
T X RX CPRI_W T X RX CPRI_E

3
T EST _T X/RXA ET H RS232 RST

EXT _ALM/ FAN

Jumper
To Antenna

Fiber
To BBU All at ON

Front and bottom of the RRU3801C module

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 8

Distributed NodeB Solution

Hardware Structure
Hardware Installation

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 9

Hardware Installation
Section 1 BBU3806 Installation
Section 2 RRU 3801C Installation Section 3 DC-BOX Installation Section 4 Hardware Installation Criterion

Summary and Typical Case

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 10

BBU3806 Installation Procedure

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 11

BBU3806 Installation Space Requirement


BBU3806 mounted on the wall

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 12

Installing BBU3806 on the Indoor Wall (1)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 13

Installing BBU3806 on the Indoor Wall (2)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 14

Installing BBU3806 on the Indoor Wall (3)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 15

Installing BBU3806 in the 19-inch cabinet


Step 1 Step 2

Typed Label paste here, Standby BBU

Typed Label paste here, Primary BBU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 16

Installing BBU3806 in the 19-inch rack(1)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 17

Installing BBU3806 in the 19-inch rack(2)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 18

BBU3806 Cables Installation


Ports and Connectors on the Panel of the BBU3806
E1 connector Power Cable

Optical Fiber

Grounding Cable
HUAWEI TECHNOLOGIES Co., Ltd.
HUAWEI Confidential
Page 19

PGND Cable Installation

Heat-Shrink Tube, Radial Shrinkage Ratio>50%,Black

1.the green and yellow PGND cable with the cross-sectional area of 6mm 2.PGND cable must be connected to the grounding bar in DC-BOX But If the distance between DC-BOX and BBU is more than 5M, the most closest grounding bar should be connected.

Making an OT terminal before connecting the PGND cable on site.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 20

The -48V DC Power Cable Installation


DC power cable introduction

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 21

The -48V DC Power Cable Installation


Heat-Shrink Tube, Radial Shrinkage Ratio>50%,Black

A. Connecting the Power Cable to BBU Directly

BBU:Common Terminal,Single Cord End Terminal,Conductor Cross Section Tin Plating,Insertion Depth 6mm,Yellow

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 22

The E1 Cable Installation


E1 cable introduction

E1 Cable should always connect to primary BBU


Both the primary and slave BBU should be labeled by print label

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 23

The E1 Cable Installation


E1 cable Introduction

All 16 connector of the E1 cable should be made carefully

Cable W1
Number 1 3 5 7 Label RX0 RX1 RX2 RX3

Cable W2

Number 1 3 5 7 2 4 6 8

Label RX4 RX5 RX6 RX7 TX4


A Pos.1 View A

2
4 6 8

TX0
TX1 TX2 TX3

Pos.44

TX5 TX6 TX7


X1 W1 W2 X2

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 24

Problem about E1 Cable Connector

In some sites, some E1 connectors are made in a quite wrong way, which will result in the E1 connectors broken.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 25

The E1 Cable Installation

Heat-Shrink Tube, Radial Shrinkage Ratio>50%,Black

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 26

BBU Fiber Installation


Cable tie is unavailable

Wound tube

Hook & Loop Mechanical Fastener, Wrap Optical Fiber

Cable tie is available in this case


HUAWEI TECHNOLOGIES Co., Ltd.
HUAWEI Confidential
Page 27

Hardware Installation
Section 1 BBU3806 Installation
Section 2 RRU 3801C Installation Section 3 DC-BOX Installation Section 4 Hardware Installation Criterion

Summary and Typical Case

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 28

RRU3801C Installation Procedure

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 29

RRU3801C Installation
Space requirements for a single 20W RRU3801C

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 30

RRU3801C Installation
Space requirements for two parallel 20W RRU3801C

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 31

RRU3801C Installation
Space requirements for tow vertical 20W RRU3801C

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 32

RRU3801C Installation
Installing the mounting bracket on the pole (1)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 33

RRU3801C Installation
Installing the mounting bracket on the pole(2)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 34

RRU3801C Installation
Main components of the RRU3801C

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 35

RRU3801C Installation
Installing the module on the mounting bracket
Step1: installation locking piece

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 36

RRU3801C Installation
Installing the module on the mounting bracket
Step2: A. Use the hole labeled 20W RRU attachment plate, as shown in Figure B. Use three M6 x 16 screws to secure the attachment plate on the module, as shown in Figure

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 37

RRU3801C Installation
Installing the module on the mounting bracket

Step3: Flip open the flaps on both sides of the mounting bracket. Then hitch the module onto the mounting bracket by fitting the tabs on the attachment plate into the anchor slots, as shown in Figure

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 38

RRU3801C Installation
Installing the module on the mounting bracket
Step4: Lead two M6 x 16 screws through the holes in the bottom of the module. Then secure the module on the mounting bracket, as shown in Figure

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 39

RRU3801C Installation
Installing the module on the mounting bracket

Step5:

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 40

RRU3801C Cables
DC Power Cable DC power cable leads external 48 V power into RRU

One end is a round water-proof connector. The other end is naked.

1 2 3 5 4 7 6 8 9

Heat-Shrink Tube, Radial Shrinkage Ratio>50%,Black RRU:Common Terminal,Single Cord End Terminal,4mm^2,20A,Inserti on Depth 10mm,Grey

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 41

RRU power Installation(Grounding of shielded layer)


Power cable
28040009:Heat-Shrink Tube,D14,Radial Shrinkage Ratio>50%,Black

-48V

GND

To Grounding Bar of DC-BOX

28040021:Heat-Shrink Tube/D6.0/Radial Shrinage Ratio %>50%/Black for shielded layer)

14170152: Naked 25030326: 3.3mm2 Crimping grounding cable Connector,2.5mm^ (not more than 1m) 2,27A,Tin Plating,Butt Splice Connector
HUAWEI Confidential
Page 42

14170017:Naked Crimping Terminal,OT,6mm ^2,M4

HUAWEI TECHNOLOGIES Co., Ltd.

Problem about fixing the waterproof terminal

In all sites, all of waterproof match terminal are not fixed. According to the installation standard, this terminal must be fixed with the power cable.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 43

RRU3801C Cables
Optical Fiber

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 44

RRU3801C Cables
Optical Fiber
Fiber connection in BBU side

Fiber connection in RRU side

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 45

RRU Fiber Installation


CPRI-W

These plugs must be retained

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 46

RRU3801C Cables
Optical Fiber

Correct installation of optical cable should be bend smoothly

Bend optical fiber too sharply in connector side

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 47

RRU3801C Cables Clamp for Power and Fiber cables if installed on tower
If RRU is installed on tower, the power cables and fiber cables must be fixed onto tower with special clamps Huawei provides. There are 2 type of clamps, one is for power cable, the other is for fiber cable, one of which can clamp 3 cables. Requirements:

One clamp is used for 1M interval.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 48

RRU3801C Cables
Protection Grounding Cable (RRU side)
Connect the OT terminal at one end of the PGND cable to the grounding bolt on the RRU3801C Grounding cable Good waterproof protection

Heat-Shrink Tube, Radial Shrinkage Ratio>50%,Black

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 49

RRU3801C Cables
RF Jumper
RF jumper is for inputting and outputting RF signals. RF jumper should be marked with label to indicate the which section it is.

(1)

(1) DIN male connector

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 50

RRU3801C Cables
RF cables

The correct installation type (1) Good waterproof and insulating protection
HUAWEI TECHNOLOGIES Co., Ltd.

The wrong installation type (1) No waterproof protection

HUAWEI Confidential

Page 51

Notes:

RRU3801C Cables
RF cables

Before cutover, Huawei RF connector should be protected by water-proof adhesive tape; Before cutover, the jumper of the antenna should be ready and the VSWR value should be measured with a SITEMASTER. For ordinary meters, the measured value should be less than 1.5. After cutover, the first thing to do is to check if there appeared any new or special alarms. After that, the VSWR value should be checked via LMT MML command DSP VSWR. If any abnormal issue was found,

SITEMASTER should be used to check for


The correct installation type (1) the VSWR value in amore detailed manner. Good waterproof and insulating protection
HUAWEI Confidential
Page 52

HUAWEI TECHNOLOGIES Co., Ltd.

Rules of Cables
Sub-contractor should provide clamps of appropriate size to fix the RRU power cable and optical fiber on the tower. All the

cables and fibers should be properly fixed on the tower in order to


prevent unwanted movement caused by wind or cyclone .Special attention should be paid to prevent the following problems from happening: A. Optical fiber under high tension force would lead to fiber alarm. B. Unwanted movement of the power cable or bad contact of jointing point for the power connector would lead to power disconnection of the RRU.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 53

Hardware Installation
Section 1 BBU3806 Installation
Section 2 RRU 3801C Installation Section 3 DC-BOX Installation Section 4 Hardware Installation Criterion

Summary and Typical Case

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 54

DC-BOX Installation
Installing DC-BOX on the wall (1)

Notes: the installation space requirement is same with BBU.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 55

DC-BOX Installation
Installing DC-BOX on the wall (2)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 56

DC-BOX Installation
Installing DC-BOX on the wall (3)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 57

DC-BOX Installation
Installing DC-BOX on the wall (4)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 58

DC-BOX Installation
Installing DC-BOX on 19 inch Cabinet

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 59

DC BOX installation and connection

DC-Box Grounding To grounding bar of room

DC Input 16>Section>6mm2

DC breaker

DC output for BBU/RRU power connection and grounding bar for BBU grounding, RRU power cable shielded layer grounding,etc. Please install from right to left

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 60

Hardware Installation
Section 1 BBU3806 Installation
Section 2 RRU 3801C Installation Section 3 DC-BOX Installation Section 4 Hardware Installation Criterion

Summary and Typical Case

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 61

Label Rules
Cable BBU power cable Label Description PWR BBU0 Remarks Each cable needs 2 pcs. Below is same. RRU power cable PWR RRU0 PWR RRU1 PWR RRU2 BBU E1 cable Fiber cable Iub 0 CPRI 0 CPRI 1 CPRI 2 BBU alarm cable ALM BBU0 For whole E1 cable

RRU jumper

ANT_0A ANT_0B ANT_1A ANT_1B ANT_2A ANT_2B

0,1,2: sector no. A: TX/RX, B: RX


Page 62

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Label Rules of DC-BOX Cables


Label content: Huawei DC BOX

Notes: this label should be printed on sites.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 63

Label Rules of E1 Cables

All 16 connector of the E1 cable should be made carefully.

E1: 16 lines.
W1: 1-8 marked as RX0-3 and TX 0-3. W2: 1-8 marked as RX4-7 and TX 4-7. Details as below: W1: 1-RX0, 3-RX1, 5-RX2, 7-RX3; 2-TX0, 4-TX1, 6-TX2, 8-TX3. W2: 1-RX4, 3-RX5, 5-RX6, 7-RX7; 2-TX4, 4-TX5, 6-TX6, 8-TX7. Sample: Notes:

RX0
UMTS

These E1 cable labels should be printed on sites.


HUAWEI TECHNOLOGIES Co., Ltd.
HUAWEI Confidential
Page 64

Output after Hardware Installation


After finished NodeB Hardware installation, It is needed to check

the quality of installation ,the following check list should be


done and the check report should be provided to Huawei with the photos of site equipments for each angle.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 65

Typical Installation Problem Case

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 66

Thank You
www.huawei.com
www.huawei.com

Page 67

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

HUAWEI TECHNOLOGIES CO., LTD.

Das könnte Ihnen auch gefallen