Sie sind auf Seite 1von 11

Flat Roof with Vent Pipe

Pipe abraided and primed with Conc.2525 Primer Sonol.Ultra Polyurethane joint sealant

Conipur Tc 458

Fall

RC Roof Slab Conc.2525

Existing Cement::Sand screed laid to fall

Gutter/Parapet wall detail on Flat Roof


3mmx3mm reglet for membrane termination filled with S.Ultra sealant

Conipur terminate 300mm high upturn tucked into reglet

Conideck system

Existing Cement:Sand screed to fall

Mortar fillet made from Conc.2525+filler

Conipur M865Z detailing to downpipe

Discharge Pipe Detail at Podium/Balcony/Terrace


Floor trap cover

FALL
Tile finishes by others Levelling screed by others Air-con discharge pipe 20mm thick cement.sand protective screed

FALL

Sonoshield HLM 6000 1:3 cement/sand screed laid to fall

150

R.C. Slab
Construction grout-shrinkage compensated grout to fill recess Discharge Pipe
3

Swimming Pool Detail


WATER LEVEL
Non slip ceramic tiles and adhesives by others Finemesh reinforcement fixed spindle at 450mm contres glued to concrete with Concresive 1438 Sonoshield HLM 6000 Non-slip ceramic tiles and adhesives by others Sonoshield HLM 6000 on 1:3 cement/sand screed laid to fall Finemesh extended to 500mm on horizontal surface 1:3 cement/sand protective screed Sonoshield HLM 6000 Masterflex 610

POOL DECK LEVEL

Angle fillet constructed from non-shrink mortar

CAR PARK BELOW

500

Gutter Detail at Roof


Protective screed reinforced with finemesh
10mm x 10mm reglet for membrane termination filled with Sonolastic NP1 sealant 50mm thick in-situ 1:3 cement/sand screed reinforced with finemesh, panels of 750mm x 750mm with 10mm wide joint filled with Sonolastic PS2 Polysulphide sealant

FALL

Drainage cell

Masterpren 2003
Separation layer

Mortar Fillet R.C. Roof Slab Sonoshield HLM 6000 Detailing around pipe Downpipe
50mm thick extruded insulation board Masterpren 2003

25mm minimum thick castin-situ 1:3 cement/sand screed laid to fall


5

DETAIL FOR PIPE PENETRATION CREATED THROUGH EXISTING FLOOR


Masterflex 610 + 611 swellable paste wrapped in helical profile HLM6000 Barralastic Masterflow 98

Bathroom Floor Slab

Plan View of Penthouse Unit at Pantip Shores

Penthouse Unit

Bathroom area

Bathroom area

Bathroom Area with brick infill wall

For brick wall the brick surface must be plastered to receive Barralastic

For shower area, upturn of 1.8m. For non-shower area 0.15m to prevent back splashing of water

Wall tiles by others


Floor tiles by others Tile bedding by others

Barralastic (2 applications) on 3:1 sand:cement screed laid to fall (optional )


Slab

10mm x 10mm mortar fillet

Bathroom Area with Stud & Frame


Drywall infill fixed to Stud & Frame To be primed with Acryl 60 to receive Barralastic
For brick wall the brick surface must be plastered to receive Barralastic

Wall tiles
Floor tiles Tile bedding

Barralastic (2 applications) Reinforced with Sonoshield Reinforcement at upturn


Slab

10mm x 10mm mortar fillet

Down Pipe Detail


Barralastic 2 coats

Floor trap cover Fall

Tiles Finishes installed Using Nano-Light


Air-con water discharge pipe

Barralastic 50mm into downpipe

Masterflow 98 non shrink grout to fill box-out opening

Discharge pipe
10

Wet Area Vent Pipe Detail


Mortar Fillet
Fall NP-1 joint sealant

Floor tiles Tile bedding 2 mm of protection layer

100mm

Barralastic Barralastic (2 coats)

Masterflow 98 to fill box-out opening in the floor pipe abraded to provide a mechanical key

3:1 sand:cement screed laid to fall (optional)

R.C Floor slab

11

Das könnte Ihnen auch gefallen