Sie sind auf Seite 1von 25

REVIEW-1 PHASE II MODELLING, DESIGN AND ANALYSIS OF SELF-ANCHORED SUSPENSION BRIDGE

DONE BY: PROJECT GUIDE:


MIRZA ABDUL BASIT BEIGH GRANDHI VENKATA ROHIT K. GURU KESAV KUMAR JASTHI SATHISH RAO 1011010112 1011010072 1011010075 1011010084

Mrs. B. VELVIZHI KUMARAVEL Assistant Professor (O.G)

PHASE- II SCHEDULE
SNO DESCRIPTION DURATION
(days) 1. Analysis 2 60 1stJanuary 2014 2. Design 2 30 1st March 2013 TOTAL 90 1stJanuary 2014 28th February 2014 30th March 2014 30th March 2014

START

END

ANALYSIS-II
Includes: Analysis of Load distribution on Deck Slab Analysis of deck slab girder

Analysis of truss
Analysis of load distribution through Suspenders and Main Cable Analysis of loads acting on Pylons

SPECIFICATIONS OF THE MODEL


1. TOTAL SPAN 2. LENGTH OF MAIN SPAN 3. LENGTH OF SIDE SPAN 4. SAG IN MAIN CABLE 5. SAG IN SIDE CABLE 6. CLEARANCE OF DECK 7. HEIGHT OF PYLON FROM DECK 8. ANGLE BETWEEN PYLON AND SIDE SPAN CABLE ( ) 9. ANGLE BETWEEN PYLON AND MAIN SPAN CABLE () 10.TOTAL NUMBER OF SUSPENDERS WITH SPACING OF 30.2775 MM 11. LENGTH OF THE MAIN CABLE 12. LENGTH OF THE SIDE SPAN CABLE = = = = = = = = = = = = 1000 MM 545 MM 227.5 MM 86 MM 15 MM 200MM 90MM 75.22 56.55 33 581.18 230
4

DESIGN OF PROTOTYPE (SCALED DOWN MODEL)


LONGITUDINAL ELEVATION:

Longitudinal Section of Self-Anchored Suspension Bridge


5

Design II
Design of the deck slab Design of the truss Design of the Suspenders and Main Cable Design of the Pylons

DESIGN OF DECK SLAB using ArchiCAD Model

3D VIEW OF DECK SLAB

DIMENSIONS OF DECK SLAB

THE INTERNAL ANGLE OF DECKSLAB IS 34.5

Staad Pro Model of Deck Slab

11

Analysis of Deck Slab girder using Finite Element Analysis

12

Application of tensile force to check the deflection under self weight.


13

Deflection under self weight after pre tensioning.

14

Global Bending Moment of deck under Self weight

15

Global Bending Moment of deck after pre tensioning

16

CALCULATION
Sag in the main cable EUDL ( Equivalent uniformly distributed load) Tension in the cable Length of the cable Sag in the main cable Sag/Span=1/6=85/545 f2=f1 * L22/L12
17

EUDL ( Equivalent uniformly distributed load) for a UDL (Uniformly distributed load shorter than span) W= 2wa/L2 (L-a/2) Where, a= Length of UDL. L= Length of span. w= Total live load. EUDL , W= 2(96)(4.2)/4.22(54.5-4.2/2) = 2395.42 KN/cm

18

2. Cable tension. T= VA2+H2 1. Horizontal force component, H= pL2/8d. P= Equivalent load. d= Sag. L= Length of mid span. H= (2395.42) (54.5)2/ 8(0.86). Horizontal component H= 1034.15 * 103 KN.

19

3. Vertical force component, VA= VB= pL/2. VA= Vertical force A. VB= Vertical force B. P= Equivalent load. L= Length of mid span. VA= VB= PL/2= (2395.42)(545)2/2 So, Vertical Component VA= VB= 652.75 x 103 KN.

20

Cable tension T= VA2+H2 T= (652.75x 103)2 + (1034.15 x 103)2 T= ((4.260 x 1011) + (1.069 x 1012)) T= 1222 x 106 KN Tan = H/V= L/4d. = tan-I (L/4a).
21

4. Length of the cable. Length of the cable S= L+(8/3)(d2/L) S =545+(8/3)(862/545) = 581m So, Length of the main cable is 581m.

22

CURRENT STATUS
Optimization of loads for deck slab Design of the deck slab girder using steel slender section Design of stiffening truss member under the deck slab

23

NEXT STEPS
Influence Line diagrams for the rolling loads Design of Cables, Suspenders and Pylons

24

OPTIMIZATION
Verification and optimization of the Analysis vis--vis design of the Self Anchored Bridge part by part and then assembled as a whole manually plus supported by software details.

25

Das könnte Ihnen auch gefallen