www.huawei.com
Learning Guide
Before studying this course, you are supposed to complete the study on
OptiX RTN 600 Product Introduction OptiX RTN 600 Networking and Protection Mechanism
Page 2
References
Digital Microwave Communications Basics OptiX RTN 600 Radio Transmission System Configuration Guide
Page 3
Objectives
Page 4
Contents
1. Preparations for the OptiX RTN 600 Commissioning
Page 5
Contents
1. Preparations for the OptiX RTN 600 Commissioning
1.1 Determining Commissioning Items 1.2 Preparing Related Documents 1.3 Preparing Related Tools
Page 6
Remarks
Required
Check fan status after power on if fan is available. Check whether all indicators work normally or not. Recommend to test if instrument
Testing indicators
Accessing the Web LCT Configuring the data Performing the service loopback test
Required
Required Required Optional
available on site.
Page 7
Remarks
Optional
Required
Required
Testing the
orderwire phone
WS.
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Required
Required
OptiX RTN 600 Radio Transmission System Quick Installation and Commissioning Guide
Page 11
Preparing Tools
The tools that are required include the common tools, special tools
tool
Instrument
Page 12
The hardware installation complete. The power supply is normal. The cable / fiber installation. Web LCT is available.
Page 13
The NE commissioning is complete. The weather condition. Safety of the operation at a high altitude.
Page 14
Summary
Page 15
Contents
1. Preparations for the OptiX RTN 600 Commissioning
Page 16
Contents
2. NE Commissioning of the OptiX RTN 600
2.1 Powering On the Equipment 2.2 Testing Indicators 2.3 Accessing the Web LCT 2.4 Configuring the Data
Page 17
Prerequisites
The power supply must be available, and the fuse capacity of the power supply must meet the requirements.
Multi-meter
Procedure
Turn off all power switches on equipment. Turn on the input power switch of the cabinet.
Page 18
Test power volt and polarity. Turn on the switch on PXC board. Monitor fan and indicators. Turn on the power of ODU.
Page 19
Testing Indicators
Prerequisites
None.
Procedure
Page 20
Prerequisites
NM interface
Procedure
Connect cable. Start Web LCT on laptop computer. Set IP of computer. Set the options of the Internet Explorer (IE).
Page 21
Page 22
Enter User Name and Password, and then click Login. The
Page 23
Prerequisites
Web LCT
Procedure
Set the new ID and IP as the planning document request. Configure all the existing boards in equipment. Monitor board indicators again.
Page 24
Checking alarm
Prerequisites
The equipment must be connected to the Web LCT. Data configuration must be complete.
Web LCT
Procedure
Select an NE from the Object Tree in the NE Explorer, and then click in the toolbar.
Prerequisites
Procedure
Disable automatic laser shutdown (ALS) function. Check the transmit and receive optical power by Web LCT or optical power meter. Judge the power value is normal or not.
Page 26
Prerequisites
Procedure
Configure the service to the boards and connect instrument well. Set hardware or software loopback and monitor service at least 5 minutes.
Page 27
Prerequisites
Procedure
Connect tester and set the outloop. Release outloop, AIS alarm should occur. All the ports can be test together.
Page 28
Prerequisites
NE configuration is complete.
Web LCT
Procedure
Set the transmitting power value for ODU. Query the actual output power value of ODU.
Page 29
Prerequisites
Procedure
Switch PXC board by Web LCT and monitor their status and alarms.
Restore back PXC board.
Page 30
Questions
How should the E1 port be set and connected for testing the connections
Why shall we disable the ATPC function when test RF transmit power?
Page 31
Summary
Testing indicators
Accessing the Web LCT Checking Alarm Configuring the data Testing the transmit and receive optical power Performing the service loopback test Testing the connections of E1 cables Testing the RF transmit power Testing the active/standby cross-connect board switching
Page 32
Contents
1. Preparations for the OptiX RTN 600 Commissioning
Page 33
Contents
3. Hop Commissioning of the OptiX RTN 600
3.1 Aligning the Single-Polarized Antenna 3.2 Aligning the Dual-Polarized Antennas
Page 34
Prerequisites
The on-site conditions and personnel fit for high altitude operation.
ATPC disabled.
Procedure
Page 35
Procedure (cont.)
RSL
VBNC
RS SI
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36
Procedure (cont.)
7. Tighten all the screws to fix antenna and make a mark. 8. Read the current RSL for both sides.
Page 37
Precautions
Align the antennas respectively in case of two antennas configured at both sides.
The antenna adjustment device is screw bolt. Make the test line with BNC interface for multimeter in advance.
Page 38
Prerequisites
The NE commissioning of the radio equipment at both ends of the radio link must be complete.
The weather must be suitable for outdoor work. There should be no rain, snow or fog between stations.
The on-site conditions must meet the requirement for performing operations at high altitudes and the personnel in charge of commissioning the antenna must be trained to work at high altitudes.
Procedure
1.Power off the vertically polarized ODUs at both ends of the radio link, power on the horizontally polarized ODUs at both ends of the radio link, and thus ensure that the antennas transmit horizontally polarized signals. 2.Adjust the azimuth angle and elevation angle of the antennas at both ends and ensure that the main lobe of the horizontally polarized signals is aligned with the antenna.
Page 40
3.Measure the RSL (P1) of the horizontally polarized signals at the local end.
4.Adjust the feed boom at the local end, and ensure that the RSL of the vertically polarized signals reaches the lower threshold (P2).
5.Record the angle (D1) of the current feed boom. 6.Power off the horizontally polarized ODUs at both ends of the radio link, power on the vertically polarized ODUs at both ends of the radio link, and thus ensure that the antennas transmit vertically polarized signals.
Page 41
7.Measure the RSL (P3) of the vertically polarized signals at the local end by referring to 3.
8.Power on the horizontally polarized ODU at the local end, and calculate the level (P4) of the horizontally polarized signals received at the local end by referring to 4. The calculated XPD2 (XPD2 = P3 P4) should not be less than
30 dB.
Page 42
10.Repeat 3 to 9 to adjust the feed boom slightly (ranging from D1 to D2), and ensure that XPD1 and XPD2 are not less than 30 dB.
Page 43
Prerequisites
Web LCT
Precautions
Procedure
Add and set the attributes of the remote NE in Web LCT Observe Login Status of the newly added remote NE.
Page 44
Prerequisites
Procedure
BER tester connected to local site. Remote site set the loopback. No errors in 5 or 10 minutes. Release all loopbacks.
Page 45
When there isnt BER tester, the PRBS function of PDH board can test the E1 service instead of BER tester.
Setting the loop-back of an E1 interface at remote site. Configuring PRBS function at local site. Observing the testing result. Releasing loop-back
Page 46
Prerequisite
Web LCT
One laptop
Page 47
Page 48
Page 49
Procedure
1.On the IDU side of NE 1, use an Ethernet cable to connect the Ethernet port of the laptop to the Ethernet service port of the Ethernet board, as shown in The Ethernet service port enables service transmission between NEs.
2.On the IDU side of NE 2, use an Ethernet cable to connect the Ethernet port of the SCC to the Ethernet service port of the Ethernet
3.Set the IP address of the laptop, and ensure that the IP address and the IP address of NE 2 belong to the same network segment.
Page 50
Display the Command Prompt window of laptop A, and run the ping 129.9.0.2 -n 200 -l 2000 command.
After you run the command, check the result. There should not
be lost packets, that is, the output display should contain the
following information: Lost = 0 (0% loss)
Page 51
Prerequisites
BER tester
Procedure
At local site, connect the BER tester to the WS port. At remote site, perform the hardware inloop for the WS port. Test the BER for 5 to 10 minutes by BER tester. No bit errors should occur. Release the loopback.
Page 52
Prerequisites
The order wire phone must be correctly installed at the station. The data of the order wire must be configured.
None.
Procedure
Dial the number of remote site. Check the voice is clear or not.
Page 53
Prerequisites
Web LCT
Procedure
Query the current clock priority table by using the Web LCT. Query the current . Manual switch the PXC board.
Page 54
Prerequisites
Procedure
Connect E1 tester in local E1 port and set loopback in remote site. Query the working status of IF board. Mute the active ODU to start the IF switch. Check status and alarms.
Page 55
Procedure (cont.)
Check the bit errors generate in switching. Test the restoration of IF 1+1 switching. Power on the main ODU.
Page 56
Prerequisites
The equipment must be configured with the SNCP protection. Antenna alignment must be complete.
Procedure
Connect tester for E1 ports and perform the bit error testing.
Power of the ODU to trigger the SNCP switch. Check the service status, alarms and bit errors. Test the restoration of SNCP.
Page 57
Prerequisites
Procedure
Page 58
Questions
How long should it take to test the E1 service and WS service respectively by using the BER tester?
How should we handle bit errors occurring in the 24-hour BER test?
Page 59
Summary
3.1 Aligning the Single-Polarized Antenna 3.2 Aligning the Dual-Polarized Antennas 3.3 Testing the ECC 3.3 Testing the E1 Service 3.3 Testing the Ethernet Service 3.4 Testing the WS Service 3.5 Testing the order wire 3.6 Testing the Clock Tracing 3.7 Testing the IF 1+1 Switching 3.8 Testing the SNCP Switching 3.9 Testing the 24-Hour BER
Page 60
Thank you