Sie sind auf Seite 1von 21

INDUSTRIAL TRAINING

PRESENTATION
ON
132KV SUBSTATION
NECSs GROUP OF INSTITUTIONS
CHIRAO,KARNAL
Presented BySOURABH
Roll no-7910476-l
7TH SEM
Electronics & communication Engineering,

CONTENTS
1.SUBSTATION.
2. CIRCUIT BREAKER
3. PROTECTIVE RELAY
4. LIGHTING ARRESTERS
5. BUS BAR
6. SWITCHES
7. CONTROL ROOM
8. TRANSFORMER
9. PLCC
10. RTU
11.SCHEMATIC DIAGRAM

An electrical substation is a subsidiary

station of a transmission and distribution


system where voltage is transformed from high
to low using transformers.
Electric power may flow through several

substations between generating plant and


consumer, and may be changed in voltage in
several steps.

It is an automatically-operated electrical

switch.
It operates both on ON LOAD and NO

LOAD conditions.

The protective relay ensures the safety of the

circuit equipments from any damage which


might otherwise cause by fault.

It is connected between the line and earth so

diverts the incoming high voltage wave to


earth.
Lightning arresters act as safety valves

designed to discharge electric surges


resulting from lightning strokes, switching
or other disturbance .

Lightning arrestors directly connected at

one end to the transmission system.

Bus-bars are merely convenient means of

connecting switches and other equipment


into various arrangements.

THERE ARE TWO TYPES OF BUS :1.Main bus


2. Transfer bus

A switch is used in an electric circuit as a


device for making or breaking the electric
circuit in a convenient way

The control room is nerve center of a power

station .
The various controls performed from here

are voltage adjustment, load control,


emergency tripping of turbines etc.

A transformer is a device that transfers

electrical energy from one circuit to


another through inductively coupled
conductors-the transformer's coils.
Types:1. STEP-UP
2. STEP-DOWN

A transformer is a static device which


transfers a . c. electrical power from one
circuit to the other at the same frequency
but the voltage level is changed

Power Line Carrier Communication, is an

approach to utilize the existing power lines


for the transmission of information.

The communication device used for the


communication over the power lines is a MODEM,
commonly known as Power Line MODEM (PLM).
It works as both transmitter and receiver, i.e., it
transmits and receives data over the power lines

It collects three primary types of data .

1.the status of process devices (digital inputs)


2. measures process variables (analog inputs)

3.accumulators (pulse inputs).

RTU database can be downloaded on

operator request, from a PC using the


SIM900 software.
The software package delivered with S900

RTU allows to handle both digital and


analog inputs/outputs

DIAGRAM OF RTU

Das könnte Ihnen auch gefallen