PRESENTATION
ON
POWER LINE CARRIER COMMUNICATION
TAKEN AT

RAJASTHAN RAJYA VIDHUT PRASARAN NIGAM LTD.

2014-2015

SUBMITTED BY:MUKUT BIHARI GUPTA


11EGCEC065

CONTENTS

HISTORY OF COMPANY
ABOUT COMPANY
VISION AND MISSION
INTRODUCTION TO PLCC
SPECIFICATIONS OF PLCC
WAVE TRAP
COUPLING
LIGHTNING ARRESTER
CIRCUIT BRACKER
BATTERY CHARGER
ADVANTAGES AND DISADVANTAGES
2

HISTORY OF COMPANY

RRVPNL is a company under the companies Act,1956


and registered with register of companies as
RAJSTHAN RAJYA VIDYUT PRASARAN NIGAM
LIMITED.

It has vide no. of 17-106485 of 2000-2001 with its


registered office at VIYUT BHAWAN,JYOTI NAGAR
,JAIPUR-302005.

It has been established on 19 July,2000 by Govt. of


Rajasthan. Under the provision of Electricity Act,2003,
declared as State Transmission Utility (STU) by govt.

ABOUT COMPANY

HEERAPURA power house is a plant of PLCC.

It known as 220KV GSS in JAIPUR.

It is used to provide electricity in long distance areas


where direct communication is not possible.

It is known as RRVPNL in JAIPUR.

RRVPNL means RAJASTHAN RAJYA VIDYUT


PRASARAN NIGAM LIMITED.

VISION AND MISSION


RSEB started from 1 July 1957
*RRVPNL is upgraded by RSEB in 1 April 2001
* It is a big organization and it functions under provisional
electricity act
AIM:- The aim of RRVPNL is to supply electricity to entire
Rajasthan state in most economical way. The target of board
is to distribute energy in new areas of RAJASTHAN as soon
as possible
5

INTRODUCTION TO PLCC
POWER LINE CARRIER COMMUNICATION
Power line carrier communication has been found to be the

most economical and reliable method for communication in a


medium and over long distance in a power system.

SPECIFICATIONS OF PLCC
1)GENERAL Carrier frequency range :- 40 to 512 KHZ
Useful AF band :- 300 to 3,700HZ

2)TRNSMITTER
R.F.TRANSMITTING POWER;

-peak envelope power :- 25w


-side band power :- 15w
7

-I.F. CARRIER FRIQUENCY

: 16 KHZ

-PILOT TONE

: 3600 HZ

-DUMMY LODE

: 20 OHMS

3)POWER SUPPLY
-DC SUPPLY

: 24 V

-CAPACITY

: 800 AH

- POWER CONSUMPTION

:< 80 W
8

WAVE TRAP
It is used to prevent the
losses in the
communication signal.

It consist of suitability
designed chock coil in
series
It prevent cross talk
9

COUPLING
COUPLING IS DONE TO COUPLE THE POWER LINE
(TRANSMISSION LINE) AND PLCC EQUIPMENT
TYPE OF COUPLING

1. PHASE TO GROUND COUPLING


2. TWO PHASE COUPLING
3. PHASE TO PHASE COUPLING
4. INTERLINE OR INTER CIRCUIT COUPLING
10

PHASE TO GROUND COUPLING

11

TWO PHASE COUPLING

12

PHASE TO PHASE COUPLING

13

LIGHTNING ARRESTER
When
(greater

high
then

voltage
normal

voltage) exist on the

Line then the arrester


immediately furnishes a
path to ground and thus
limit and drains off the
excess voltage
14

CIRCUIT BRACKERS
These are use to operate on the faulty either on line or
transformer, depending upon where it is used
These isolate the faulty line or equipments from the line
operation of the substation by operating automatically

through protective relay .

15

TYPE OF CIRCUIT BRACKERS


AIR BLAST CIRCUIT
BRACKER

VACCUME CIRCUIT
BRACKER

16

BATTERY CHARGER
When power is goes off then for providing power to the
PLCC equipment the battery will be used.
24 battery are connected in series individually battery are
approx 2v provide 48volt.

Battery charger consist 2 sections


1. FLOAT CHARGER
2. BOOST CHARGING

17

TECHNICAL SPECIFICATIONS
NORMAL INPUT
:415 V AC 3-PHASE
INPUT VARIATION
: +/- 20%
FLOAT CHARGER :
DC OUTPUT
:50 V
OUTPUT CURRENT
:20 TO 40 AMP
EFFICIENCY
: >70%
BOOST CHARGER :
DC output
- 43.2 to 67.2 V
Output current
- 25-70 Amps.
Efficiency
->80%
18

ADVANTAGES OF PLCC
1. The cost is less.

2. Power lines have appreciably higher mechanical strength compared


with ordinary lines. They would normally remain unaffected under the
conditions, which might seriously damage telephone lines.
3. Power lines usually provide the shortest route between the power
stations.
4. Power lines have large cross-sectional area resulting in very low
resistance per unit length. Consequently carrier signals suffer much
less attenuation than when they travel on telephone lines of equal
lengths.

19

DISADVANTAGES OF PLCC
1. Proper care has to be taken to guard carrier equipment and
persons using them against high voltages and currents on the
lines.
2. Reflections are produced on lines connected to high voltage
lines. This increases attenuation and creates problem.
3. High voltage lines have transformer connections, attenuate
carrier currents. Sub-station equipments adversely affect the
carrier currents.
4. Noise introduced by power lines is far more than in case of
telephone lines. This is due to the noise generated by discharge
across insulators, corona and switching processes.
It is obvious that an effective power lines carrier system must
overcome these difficulties.
20