Beruflich Dokumente
Kultur Dokumente
Unit 5
Thermal and Non-Thermal
Preservation
Thermal
Pasteurization
Commercial Sterilization
Non-thermal
Low Temperature
Irradiation
Chemical
Micro filtration
High Pressure
Pulsed electric field
Pasteurization
Derives its name from the mild heat
Pasteurization
The process of pasteurization is based on
Pasteurized Foods
The most common pasteurized food is milk
Originally designed to eliminate
O157:H7
Beer
Spoilage bacteria and yeast
Pasteurized Foods
Liquid egg
Salmonella and spoilage bacteria
Honey
Spoilage yeast
Campylobacter
Milk Pasteurization
Time/Temperature Combinations
High Temperature Short Time (HTST) 15 sec @
72oC
Low Temperature Long Time (LTLT) 30 min at
63oC
These pasteurization time/temperatures are
considered to be equivalent.
Heat treatments are established on the
basis of safety first (elimination of
pathogens) and spoilage (extension of shelf
life) second.
Commercial Sterilization
Some milk is sold in cans (evaporated or
microorganisms
Essential in clinical settings (surgical
instruments)
Commercial Sterilization: A product is not
necessarily free of all microorganisms, but
those that survive the sterilization process
are unlikely to grow during storage and
cause spoilage
Commercial Sterilization
A product that has undergone commercial
sterilization is free of vegetative and sporeforming pathogens and spoilage
microorganisms that are capable of growing
in that food under typical non-refrigerated
storage conditions
Most common commercially sterilized foods
are canned products
Commercial Sterilization
Primary Objective:
D value
Z value
F value
D -value
D-value- Decimal Reduction Time: Is the time
needed to reduce a population of microorganisms
by 90% (1 log cycle) at a specified temperature
and in a specified medium
If the initial population was 100 CFU/ml
10 CFU/ml would remain after a 1 log cycle
reduction
D -value
D-value
105
104
D value Formula
DT Value = t2-t1/ (log N0-log N1)
T= temperature
t1= initial time
t2= final time
N0= initial population
N1= final population
From previous example:
D121= 45-30/5-4
= 15/1= 15 sec
Z- Value
Z-value: is the change in temperature required
to produce a 10-fold change (1 log) in D-value.
Z-values are calculated from the slope of the
curve of D-value vs temperature
Z- Value
Z
D-value
Z- Value Formula
Z = T2 T1/ log a- log b
T2= Final temperature
T1= Initial temperature
a = upper D-value
b = lower D-value
From previous figure:
Z= 240-220/log 100- log 10
Z= 20/2-1
Z= 20oF
Exercise
D value determination for E. coli O157:H7 in beef at
60oC: Calculate the D value of the organism under these
conditions
Time (min)
Log10viable count
(cfu/g)
0.2
7.1
0.5
6.5
1.0
55
60
0.75
-0.7