Sie sind auf Seite 1von 105

ZXMW NR8250 V1.

00 COMMISSIO
NING GUIDE

Microwave Product Support Dept


2012.May

>internal only

Course Purpose
Intended Audience
Commissioning & maintenance engineers

After this Course, you should be able to:


Complete the software commissioning of ZXMW NR8250(V1.00)
equipment independently.
Know the issues to be noticed during installation.

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>Internal only

Commissioning Preparations
start
Commissioning
preparations
Check before
power-on
Check after
power-on

Sorts

Contents

Project
information
collection

Address and contact.


Information about preparations before project.
Detailed information about configuration and
version.

Tools and
instruments
preparation
s

Tools and instruments for commissioning.


All instruments should be verified by the
National Metrology Department.

Software
preparation

Confirm if IDU upgrade is needed.


Upgrade software packet should be prepared if
needed.
The version should be tested and officially
released .

Software
configuration
Adjusting
antenna
End

Networking

Confirm the networking, draw the topology,


acknowledge the connection and position of
each equipment.
Commissioning
Confirm the IP addresses and routers of each
Preparations List
NE.
ZTE Corporation. All rights
reserved.

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>Internal only

Power-on
Sorts

Contents

Voltage
Checkup

All switches are off, no short circuits on power supply, correct marker on cables,
ground cables connected normally;
Switch on the supply circuit, confirm the polarity and voltage of power supply after
checkup.

Rack
Checkup

Checkup by vision if the installation of rack and module are neat and artistic, and
the screws are fasten.
Cables are allocated normative, bound logically and arranged clearly. Tabs on
label are unified and clear, easy to check and stable.

Board
Checkup

Types, quantities and positions of each board are correct.

Cable
Checkup

Power supply cable: connection is fasten and polarity is correct.


Ground cable: connection is fasten.
IF cable: the cable shouldnt be short or open circuit, ground cable is fasten,
connection to ODU and IDU are normal, waterproof handling is performed on
connector.

Antenna
Checkup

Antenna and low-loss RF cable are installed: low-loss RF and the connector are
intact, and the connector is connected normally, the antenna is toward the correct
direction, the antenna and low-loss RF are correctly connected.

Power-on

Switch on the PD cabinet, switch on the power module of IDU, switch on all
boards.

Checkup
after
Power-on

Power
Supply to
IDU

LED indicators on panels are working normally, which should be green and
flashing slowly.

Checkup
before
Power-on

Checkup List
before Power-on

Checkup List
after Power-on

ZTE Corporation. All rights


reserved.

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>internal only

Logging in to
Web LMT
Panel Description

IP Address Configuration

Logging in to Web LMT

Check IDU Version

Check ODU Version

>Internal only

3.1 Panel Description(1/2)

ZTE Corporation. All rights


reserved.

>Internal only

3.1

Slot10
Slot11
Slot12

PM
PM
RPU

Panel Description(2/2)

Slot1
Slot2
Slot3
Slot4
RCU
RCU/RTU
RTU/RMU
RTU/RMU

Slot5
Slot6
Slot7
Slot8
RTU/RMU
RTU/RMU
RTU/RMU
RTU/RMU

Boar
d
type

Board
name

RCU

RCUB

RMU

Slot9

RMUC

RTU

Core Control &


Clock Unit
Modem Card with
XPIC

1-2
3-8

RMUD

Modem Card

3-8

RTUA

PDH Traffic Card

2-8

RTUC

PDH Traffic Card

2-8

RTUB

RFA

Availab
le slots

Function

RTUNO
RTUNE
RTUHO
RTUHE

SDH+PDH Traffic
Card
Ethernet Traffic Card
(Optical)
Ethernet Traffic Card
(Electrical)
TDM+Ethernet Traffic
Card
TDM+Ethernet Traffic
Card

2-8
2-8
2-8
2-8
2-8

PM

PM3

IDU Power Supply

10-11

RPU

RPUA

ODU Power Supply

12

RFA

RFAB

Fan Unit

9
ZTE Corporation. All rights
reserved.

>Internal only

3.2 IP Address Configuration

2
3

If RCUA is inserted in slot1, input 192.254.1.x in IP address


If RCUA is inserted in slot2, input 192.254.2.x in IP address
x range from 1 to 254, subnet mask is 255.255.255.0.
ZTE Corporation. All rights
reserved.

>Internal only

3.3

Logging in to Web LMT(1/2)

Connect IDU and PC.

Direct or crossover Ethernet are all applicable.


ZTE Corporation. All rights
reserved.

>Internal only

3.3

Logging in to Web LMT(2/2)

Logging in to the Equipment


Double-click the internet Explorer on the desktop, input 192.154.1.16 as the IP a
ddress of IDU and press Enter button, then enter the logging in page.
Input user name admin in UserName.
Input user name admin in Password .
Click LOGIN to log in.

If RCUA is inserted in slot1, input 192.254.1.16


If RCUA is inserted in slot2, input 192.254.2.16.
ZTE Corporation. All rights
reserved.

>Internal only

3.4

Check IDU Version

Checkup the correctness of IDU version, upgrade the version if nec


essary.
Select Maintenance >Version >IDU ]in the left navigation tree, checkup the run
ning IDU version in the Management Package Version field, and the Running
Status of current running version should be RUN.

ZTE Corporation. All rights


reserved.

>Internal only

3.5

Check ODU Version

Checkup the correctness of ODU version, upgrade the version if nec


essary.
Select Maintenance > Version > ODU in the left navigation tree, check the ODU
version.

ZTE Corporation. All rights


reserved.

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>internal only

Parameters Confi
guration

NE Basic Information Configuration


Network Management Configuration
Shelf Configuration
Radio Link Configuration
TDM Service Configuration
Ethernet Service Configuration
Clock Configuration
System Time & Time Zone Configuration
Fan Configuration
EOW Configuration(optional)
XPIC Configuration(optional)

>Internal only

4.1 NE Basic Information Configuration

Configuration should be according to network management plan.


ZXMW NR8250 V1.00 supplies static route configuration function for connecting with third-part equipments, and
still the equipment works as L2 switch.

ZTE Corporation. All rights


reserved.

>Internal only

4.2 Network Management Configuration(1/2)

Switch configuration
Disable no filtering on network management server.
Enable SNMP IP need to be added.
ZTE Corporation. All rights
reserved.

>Internal only

4.2 Network Management Configuration(2/2)

Switch configuration
Enable Trap massages will be sent to all the IP addresses existing in the IP Address List when occurs.
Disable NE wouldnt send Trap massages.
ZTE Corporation. All rights
reserved.

>Internal only

4.3 Shelf Configuration(1/2)

ZTE Corporation. All rights


reserved.

>Internal only

4.3 Shelf Configuration(2/2)

According to the actual situation of the boards inserted in IDUs slots


, set the following information for each SLOT NO.: Board Type, Tra
nsmit Unit, Function, and select Master Slot or Slave Slot.
If Function of RTUB board is set to STM-1 ADM/TM, E1 and STM-1 ser
vice are supported.
If Function of RTUB board is set to STM-4 /STM-1 Transparent, E1, S
TM-1 and STM-4 service are supported..
Function is set to default for other types of boards.

Note:
Slot 1 can only be set to RCUA board.
Slot 2 can be set to RCUA or RTU board.
Slot 3-8 can be set to RTU or RMU board.

ZTE Corporation. All rights


reserved.

>internal only

4.4 Radio Link Configuration

Transmit Unit Configuration

Work Mode Configuration

Protection Parameter Configuration

ATPC Parameter Configuration

ACM Functions Configuration

ODU Parameter Configuration

choose Transmit unit to configuration

>Internal only

4.4.1 Transmit Unit


Configuration

ZTE Corporation. All rights


reserved.

>Internal only

4.4.2

Working Mode Configuration

Select the bandwidth assigned to TDM service in the Work Mode drop-down
list box, and the rest bandwidth will be assigned to Ethernet service.
Bandwidth and modulation mode decide the capacity of transmission. Boarder
bandwidth and higher modulation mode will offer more capacity at the cost of
transceiving performance degradation.

ZTE Corporation. All rights


reserved.

>Internal only

4.4.3

Configure the Protection Type according to the MW design.

Protection Parameter Configuration

No Protection indicates the system has no protection.


HSB indicates the system adopts the protection of 1+1 hardware hot backup.
SD indicates the system adopts the protection of antenna diversity reception.
FD indicates the system adopts the protection of different transmitting and receiving frequen
cies.

If one type of protection is adopted, the Protection Mode can be configured.

Revertive indicates when service signal on active path become normal, the service will swit
ch back to it, and the Revertive Time should be set, which range from 300s -800s.
Automatic indicates the system will switchover automatically according to the status of activ
e and standby path.
If Manual is selected, and the protection type is HSB or SD, the IF&RF Tx Path should be s
pecified. If protection type is FD, only IF TX Path need to be specified.

ZTE Corporation. All rights


reserved.

>Internal only

4.4.4

ATPC Parameter Configuration

If ATPC Enable is set to ON, ATPC High Threshold and ATPC Low Threshold should
also be configured. Usually, the two parameters are recommended to use the default va
lue.
Max Tx Power and Min Tx Power need to be set within the range of ODU transmitting
power.
When adjusting the antenna, ATPC Enable must be set to OFF.

ZTE Corporation. All rights


reserved.

>Internal only

4.4.5

ACM Functions Configuration

End Profile should be higher than Start Profile, and the ACM function wouldn't wo
rk if they are set the same.
When adjusting the antenna, ACM Enable should be set to OFF.
The ACM function can work only when both ends are enabled.
Changing ACM Enable will cause instantaneous service interruption.

ZTE Corporation. All rights


reserved.

>Internal only

4.4.6

ODU Parameter Configuration

The unit of Current Rx/Tx Frequency is kHz.


The Tx Frequency should be set within the Tx Frequency Range.
The RSL High Threshold and RSL Low Threshold can be set to d
efault value if theres no special requirement.

ZTE Corporation. All rights


reserved.

>internal only

4.5 TDM Service Configuration

Cross Connection Configuration

Cross Connection Configuration


Example

SNCP Configuration optional

SNCP Configuration
Example optional

>Internal only

4.5.1

Cross Connection Configuration(1/6)

ZTE Corporation. All rights


reserved.

>Internal only

4.5.1
6)

Cross Connection Configuration (2/

ZTE Corporation. All rights


reserved.

>Internal only

4.5.1
6)

Cross Connection Configuration (3/

Shelf Configuration

ZTE Corporation. All rights


reserved.

>Internal only

4.5.1
6)
N
o.

Cross Connection Configuration (4/

Board Type

Supported
Ports
16E1

Description

RTUA

No multiplexing function. RTUB


board is needed when
multiplexed on STM-1

RTUB(ADM/TM) STM-1 and E1

Support VC12, VC4 cross


multiplexing.

RTUB(Transpar
ent)

STM-4 and
STM-1

Support VC4 cross multiplexing.

RMUB

STM-1 or E1

STM-1 and E1 cant be


configured at one time.

RMUC

STM-1 or E1

STM-1 and E1 cant be


configured at one time. Support
XPIC.

ZTE Corporation. All rights


reserved.

>Internal only

4.5.1
6)

Cross Connection Configuration (5/

Radio Link Configuration

Support 16E1

Support 1 STM-1

ZTE Corporation. All rights


reserved.

>Internal only

4.5.1
6)

Cross Connection Configuration (6/

Conditions for cross connection configuration


RTU to RMU Service access/achieve
RTU to RTU TDM service multiplexing/demultiplexing
RMU to RMU TDM service connection for node type site

Cross connection configuration should be according to MW design.


The cross connection can be checked in P2P Table after configured

ZTE Corporation. All rights


reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (1/10)
E1 configuration example 1 RTUARMUB(E1)
Source RTUA slot2 s 1st E1 port.
Destination RMUB slot5 s 11th port.
Support 16E1

Cross Level should be set to VC12 when configuring E1 service.


Cross Direction is normally set to Bidirectional.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (2/10)
E1 configuration example 2 RTUARMUB(STM-1)
Source RTUA slot2 s 10th E1 port.
Destination RMUB slot6 s 2nd E1 in 1st STM-1 timeslot.
Support STM-1

To configure E1 multiplexed to STM-1, RTUB board is needed and must be


set to STM-1 ADM/TM.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (3/10)
E1 configuration example 3 RTUB(E1)RMUB(E1)
Source RTUB(slot2)s 1st E1.
Destination RMUB(slot5)s 3rd E1.
Support 16E1

When RTUB is working at VC12 level, Port Number denotes the E1 ports if
Timeslot is set to 0.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (4/10)
E1 configuration example 4 RTUB(STM-1)RMUB(E1)
Source RTUB(slot2)s 2nd E1 in 1st STM-1.
Destination RMUB(slot5)s 3rd E1.
Support 16E1

When RTUB is working at VC12 level, Port Number denote the STM-1 port
if the Timeslot value is not set to 0, which range from 1-63.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Example


(5/10)
E1 configuration example 5 RTUB(E1)RMUB(STM-1)
Source RTUB(slot2)s 1st E1.
Destination RMUB(slot6)s 2nd E1 in 1st STM-1.
Support STM-1

When RTUB is working at VC12 level


Port Number denotes STM-1 port, range from1-2.
Timeslot denotes E1 port in STM-1, range from 1-63.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (6/10)
E1 configuration example 6 RTUB(STM-1)RMUB(STM-1)
Source RTUB(slot2)s 2nd E1 in 1st STM-1.
Destination RMUB(slot6)s 3rd E1 in STM-1.

Support
STM-1

ZTE Corporation. All rights


reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (7/10)
E1 configuration example 7 E1 configuration in bulk.
Source RTUB(slot2)s 1st -10th E1 in 1st STM-1.
Destination RMUB(slot6)s 1st -10th E1 in 1st STM-1 .
Support STM1

Timeslot for STM-1 can be configured in bulk by adding - between start and
end E1 ports.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (8/10)
STM-1 configuration example 1
Source RTUB(slot3)s1st STM-1.
Destination RMUB(slot6)s 1st STM-1
Support STM1

ZTE Corporation. All rights


reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (9/10)
STM-1 configuration example 2
Source RTUB(slot4)s 2nd STM-1.
Destination RMUB(slot6)s 1st STM-1.
Support STM-1
Transpare
nt

When working at VC-4 Level, 2nd STM-1 port of RTUB can work as STM-1 or STM-4 port.
If Channel No. is 0 ,port works as STM-1.
If Channel No. isnt 0 the value denotes the 1 - 4 STM-1 in STM-4.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.2 Cross Connection Configuration Exa


mple (10/10)
STM-1 configuration example 3
Source RTUB(slot4)s 1st STM-1 in STM-4.
Destination RMUB(slot6)s 1st STM-1.
Support STM1
Transpare
nt

When working at VC-4 Level, 2nd STM-1 port of RTUB can be set as STM-1 or STM-4 port.
If Channel No. is 0 ,port works as STM-1.
If Channel No. isnt 0 the value denotes the 1 -4 STM-1 in STM-4.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.3 SNCP Configuration optional (1/


6)
Conditions
The TDM Mode must be set toSTM-1.
RTUB is needed and must be set to ATM-1 ADM/TM , which can rea
lize E1 service multiplexing to STM-1

Cross Level must be set to VC12.


Channelize STM-1.

ZTE Corporation. All rights


reserved.

>Internal only

4.5.3 SNCP Configuration optional (2/


6)
Shelf Configuration

ZTE Corporation. All rights


reserved.

>Internal only

4.5.3 SNCP Configuration optional (3/


6)
Radio Link Configuration

ZTE Corporation. All rights


reserved.

>Internal only

4.5.3 SNCP Configuration optional (4/


6)
SNCP Channel

ZTE Corporation. All rights


reserved.

>Internal only

4.5.3 SNCP Configuration optional (5/


6)
Active

Select all items

click item to select

ZTE Corporation. All rights


reserved.

>Internal only

4.5.3 SNCP Configuration optional (6/


6)
SNCP Channel

Auto The protective switchover is performed according to the alarm status of SF and SD and the
configured revertive module.
Protect Lockout No protective function is provided.
Force to Slave Perform forced switchover towards the standby channel, without considering the
standby channels status.
Force to Master Perform forced switchover towards the active channel, without considering the
active channels status.
Manual to Slave Perform switchover towards the standby channel if the standby channel is
available.
Manual to Master Perform switchover towards the standby channel if the active channel is
available.
SNCP Clear Command Clear the previously executed command.
ZTE Corporation. All rights
reserved.

>Internal only

4.5.4 SNCP Configuration Example opti


onal (1/2)
SNCP Configuration Example 1 RTUA to RMUB
RTUA(solt3)s all 8 E1 connected to RMUB(slot5)s 1-8E1 in 2nd
STM-1.
RMUB(slot6)s 1-8E1 in 1st STM-1 work as RMUB(slot5)s standby.

ZTE Corporation. All rights


reserved.

>Internal only

4.5.4 SNCP Configuration Example opti


onal (2/2)
SNCP Configuration Example 2 RTUB to RMUB
RTUB(solt4)s 2nd STM-1 connected to RMUB(slot5)s 1st STM-1.
RMUB(slot6)s 1st STM-1 works as the RMUB(slot5 )s standby.

STM-1 protection must be made by E1 cross connection for SNCP only can work at VC12 level.
ZTE Corporation. All rights
reserved.

>internal only

4.6 Ethernet Service Configuration

General Configuration

Eth Port Configuration

Eth Port Description


Configuration optional

VLAN Configuration

FC & Rate Configuration

LAG Configuration

QoS Configuration

STP/RSTP Configuration optional

>Internal only

4.6.1

General Configuration

Transparent Mode will shut down the switch function, is not commonly used.
Age Time refers to aging time of MAC address list, the default value is 300s, which usually dont need to change.
Default VLAN ID is contained by all ports.
Wireless Network Capacity should be configured according to the number of NEs, normally set to 5M.
ZTE Corporation. All rights
reserved.

>Internal only

4.6.2 Eth Port Configuration

Configure as
requirement

ZTE Corporation. All rights


reserved.

>Internal only

4.6.3 Eth Port Description optional

Input description words according to


real situation.

ZTE Corporation. All rights


reserved.

>Internal only

4.6.4

VLAN Configuration(1/3)

Access Port

VLAN can only be configured under VLAN Mode.


ZTE Corporation. All rights
reserved.

>Internal only

4.6.4

VLAN Configuration(2/3)

Trunk Port

Add Add a specified range of VLANs.


Add all Add all 4094 VLANs.
Add all except Add all VLANs except specified range.
Remove Remove a specified range of VLANs.
Remove all Remove all VLANs.

ZTE Corporation. All rights


reserved.

>Internal only

4.6.4 VLAN Configuration(3/3)


Hybrid Port

UnModify The equipment wouldnt modify the frames ingressive or egressive.


UnTag PVID The frames carrying the same VLAN ID as the PVID will be untagged, and under rest situation works the
same as UnModify.
ZTE Corporation. All rights
reserved.

>Internal only

4.6.5 LAG Configuration

Select HASH normally

Define LAG ID 0-15


Select LAG members

Show selected members


Set Master Port

LAG Link Aggregation Group.


Configurations of ports in the same LAG must be identical.
ZTE Corporation. All rights
reserved.

>Internal only

4.6.6 FC & Rate Configuration

Priority 0-7

ZTE Corporation. All rights


reserved.

>Internal only

4.6.7 QoS Configuration (1/4)

Schedule

SP Strict Priority. Under this mode, the queues will be sent strictly according to priorities, the q
ueue can only be sent when queues with higher priorities are empty.
WRR Weighted round-robin a scheduling algorithm. All queues all scheduled according to th
eir weighs.
SP+WRR A combination of above 2 algorithms.
ZTE Corporation. All rights
reserved.

>Internal only

4.6.7 QoS Configuration(2/4)


Priority selection

802.1p(VLAN) Adopts protocol 802.1p, which means, VLAN.


DSCP/IP-TOS The priority is assigned by DSCP/IP-TOS.
802.1p(VLAN) over DSCP The VLAN is based on DSCP.
DSCP over 802.1p(VLAN) The DSCP is based on VLAN.

Congestion strategy

Tail Drop Tail Drop indicates when the queue is full, all incoming frames will be
discarded, which may cause global synchronization.
RED The frames will be discarded by detecting the length of the queue, only a
small amount of frames will be discarded, which can avoid TCP global
synchronization.

ZTE Corporation. All rights


reserved.

>Internal only

4.6.7 QoS Configuration (3/4)


QoS Weight Configuration

Configure the weights of Queue1-Queue8 according to actual requirement.


Weight values 1-32, 1 is the lowest and 32 is the highest.

VLAN Priority configuration

0-7 are priorities on VLAN tag.


Assign Queue1-Queue8 to VLAN priorities of 0-7 according to actual requirement.

ZTE Corporation. All rights


reserved.

>Internal only

4.6.7 QoS Configuration(4/4)


QoS Weight Configuration

0-63 are priorities on DSCP.


Assign Queue1-Queue8 to DSCP priorities of 0-63 according to actual requirement.
ZTE Corporation. All rights
reserved.

>Internal only

4.6.8 STP/RSTP Configuration(1/3)

Select
Click Apply
STP Configuration Interface

Select
Click Apply
RSTP Configuration Interface

Select
Click Apply

The pages are different based on different active STP/RSTP protocols.

ZTE Corporation. All rights


reserved.

>Internal only

4.6.8 STP/RSTP Configuration(2/3)


Click page label

Configure parameters of net bridge

Click to enter port configuration


page

The restrict relationship of Hello Time Forward Time Max Age is


(Hello Time 1)2Max AgeForward Time 1)2.
ZTE Corporation. All rights
reserved.

>Internal only

4.6.8 STP/RSTP Configuration(3/3)


Port parameters configuration

STP port configuration

Select Yes or No for Edge Port


RSTP port configuration
ZTE Corporation. All rights
reserved.

>internal only

4.7 Clock Synchronization Configuration

Clock Synchronization Configuration

Clock Synchronization Configuration Example

>Internal only

4.7.1 Clock Synchronization Configuration(1/4)


Current Clock Information

ZTE Corporation. All rights


reserved.

>Internal only

4.7.1 Clock Synchronization Configuration


(2/4)

Clock Protection Switching Strategy

GPS M/S Stations

Mater Station Select GPS Master Station when the clock in RCUA board works as clock source.
Slave Station Other conditions.

BITS Clock Output

No Protection Policy Only adopt the primary clock, if the primary clock degrades, it will keep curre
nt frequency for a bit of time, then switch to enforced clock PLL free running.
Auto-switching Policy Non-real-time priority switching Switch to subordinate clock if exists w
hen primary clock is degrading or lost and wouldnt switch back to primary clock even if primary clock
turns normal.
Optimal Switching Policy Real-time priority switching Switch to subordinate clock if exists w
hen primary clock is degrading or lost and switch back to primary clock if primary clock turns normal.

Open Clock signal is output from CLK IN/OUT port.


Close No clock signal is output from CLK IN/OUT port.

BITS Clock Mode can configure the clock mode normally chose 2.048Mbps.
Enforce Clock PLL Free Running can chose Yes or No chose Yes when transmitting syn
chronous Ethernet service.
NE in Ring Network, configure according to real situation.

ZTE Corporation. All rights


reserved.

>Internal only

4.7.1 Clock Synchronization Configuration


(3/4)
Reference Clock Configuration

Click to add to
right column
Select needed Clock Source

Click Apply
ZTE Corporation. All rights
reserved.

>Internal only

4.7.1Clock Synchronization Configuration(4/4)


Clock Source Configuration
Mater Station Clock Source

Slave Station Clock Source

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration Exa


mple (1/7)
Master StationPLL Free Running

When choosing PLL, other


configurations are disabled.

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration Exa


mple (2/7)
Master StationGPS Clock

When choosing PLL, other


configurations are disabled.

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration Exa


mple (3/7)
Master StationBITS Clock

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration Ex


ample (4/7)
Slave Station distract clock from RMU no prot
ection

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration E


xample (5/7)
Slave Station distract clock from RMU, 1+1 protectio
n

Clock is extracted from 2 radio links under 1+1 protection mode in this example.

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration E


xample (6/7)
Slave Station distract clock from RTU

The Clock Source should be selected from Eth or STM-1 port according to the
service type, and E1 port cant be selected as Clock Source.

ZTE Corporation. All rights


reserved.

>Internal only

4.7.2 Clock Synchronization Configuration


Example (7/7)
Clock Ring

Clock is extracted from 2 radio links of different directions in this example.

ZTE Corporation. All rights


reserved.

>Internal only

4.8 System Time & Time Zone Configuration

ZTE Corporation. All rights


reserved.

>Internal only

4.9 Fan Configuration

Fan Control Mode

Fan Speed

Fan Speed can be configured in Manual Mode.

ZTE Corporation. All rights


reserved.

>Internal only

4.10

EOW Configuration optional

Select
corresponding unit

The slot number is shown in the list according to the position of RMU in the
shelf.

ZTE Corporation. All rights


reserved.

>internal only

4.11 XPIC Configuration option


al

Slot requirement

Configuration requirement

2+0 XPIC Configuration Example

2+2 XPIC Configuration Example

>Internal only

4.11.1

Slot requirement (1/2)

2+0 XPIC
RMUC board is required for XPIC configuration.
Up to 3 XPIC groups can be configured, which is slot 3+4, slot 5+6, slot 7+8.
Two XPIC boards must be in the same XPIC group.

ZTE Corporation. All rights


reserved.

>Internal only

4.11.1 Slot requirement (2/2)


2+2 XPIC
RMUC board is required for XPIC configuration.
Only one XPIC group can be configured, which contains slot 5, 6, 7, 8.
Four XPIC boards must be in the same XPIC group.

ZTE Corporation. All rights


reserved.

>Internal only

4.11.2

Configuration Requirement

IDU Software Version


Software version should be 020 which is V1.00.020xxxxxx

Radio Link Bandwidth


The configuration of boards within one XPIC group must be identical.
The bandwidth should be 28M or 56M.

ODU Parameters
Tx and Rx frequencies of RMUC boards must be identical within one gr
oup.

Protection Mode
For 2+2 XPIC mode protection mode must be configured and H
SB or SD is optional.

LAG
RMUC boards in the same group must be set to one LAG group.

ZTE Corporation. All rights


reserved.

>Internal only

4.11.3
/5)

2+0 XPIC Configuration Example (1

ZTE Corporation. All rights


reserved.

>Internal only

4.11.3
/5)

2+0 XPIC Configuration Example (2

Bandwidths of 2 units should be identical

Both units should be No Protection

ZTE Corporation. All rights


reserved.

>Internal only

4.11.3
/5)

2+0 XPIC Configuration Example (3

Frequencies of 2 ODU should


be identical

ZTE Corporation. All rights


reserved.

>Internal only

4.11.3
/5)

2+0 XPIC Configuration Example (4

Put into one LAG

ZTE Corporation. All rights


reserved.

>Internal only

4.11.3
/5)

2+0 XPIC Configuration Example (5

ZTE Corporation. All rights


reserved.

>Internal only

4.11.4
/5)

2+2 XPIC Configuration Example (1

ZTE Corporation. All rights


reserved.

>Internal only

4.11.4
/5)

2+2 XPIC Configuration Example (2

Bandwidths of 2 units should be identical

Protection Mode of 2 units should be identical, HSB or SD

ZTE Corporation. All rights


reserved.

>Internal only

4.11.4
/5)

2+2 XPIC Configuration Example (3

Frequencies of 2 ODU should


be identical
ODU

ZTE Corporation. All rights


reserved.

>Internal only

4.11.4
/5)

2+2 XPIC Configuration Example (4

Put into one LAG

ZTE Corporation. All rights


reserved.

>Internal only

4.11.4
/5)

2+2 XPIC Configuration Example (5

ZTE Corporation. All rights


reserved.

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>Internal only

Test Recording
Checking and recording are required after commissioning.
Power supply and hardware need to be checked.
Parameters should be recorded.
Current alarm.

Commissioning
Test Record of ZXMW NR8250

ZTE Corporation. All rights


reserved.

>internal only

Contents
Commissioning Preparations

Power-on

Logging in to Web LMT

Parameters Configuration

Test Record

FAQ

>Internal only

FAQ
Link Lost
Refer to MW Trouble Shooting Guide Check parameters, RSL, inference
s, XPD, and so on.

Link is locked-on, service is lost


E1 service Check if E1 cable connection is correct, fixed, cross conne
ction configuration is correct, perform testing if necessary.
STM-1 service Check if STM-1 cable connection is correct, fixed, cro
ss connection configuration are correct, perform testing if necessary.
IP service Check if working mode, port configuration, VLAN configurat
ion are correct. Check Ethernet cable quality, connection.

Instantaneous interception
If the connection of service cable, IF cable are fixed.

If the configurations of ports parameters are matching.


Check radio parameters, RSL, inferences, XPD, and so on.

ZTE Corporation. All rights


reserved.

Thanks!