Sie sind auf Seite 1von 14

Strictly confidential

1
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

Common Abis Closing Workshop


CARE services, Telkomsel network
22nd 24th February 2012, Denpasar

Strictly confidential
2
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

OAM Alarm Handling


Part I

3273 GPRS/EDGE TERRITORY FAILURE


3265 UNEQUIPPED A INTERFACE CIRCUIT
2725 ADJACENT CELL IDENTIFIER CONFIGURATION ERROR
7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
7744 EXCESSIVE TCH INTERFERENCE

Strictly confidential
3
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

3273 GPRS/EDGE TERRITORY FAILURE


Meaning
GPRS/EDGE territory size in the normal area of BTS is below the limit specified by the BTS specific radio
network parameter 'default GPRS capacity (CDEF)' or the number of connected GPRS/EDGE channels
(EGTCH) in the extended or super extended area of the BTS is smaller than the number of EGTCHs
configured by operator. The BSC has not been able to add more radio channels to the territory within the
informing delay of this alarm (180 seconds). The BSC's ability to transfer GPRS/EDGE traffic in the BTS has
been reduced or totally prevented.
Instructions
If the alarm indicates a lack of PCUPCM resources in the packet control unit (PCU), you should consider the
following options:
1. Reducing the default GPRS/EDGE / extended cell area GPRS/EDGE / super extended cell area
GPRS/EDGE channels connected to PCU
2. Reducing the amount of dynamic Abis pool (DAP) timeslots connected to the PCU
3. Moving one cell/segment from the failed PCU to another PCU
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.

Strictly confidential
4
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

3265 UNEQUIPPED A INTERFACE CIRCUIT


Meaning
BSC does not recognize the Circuit Identification Code (CIC) of a message it has received, or the destination
point acknowledges that it does not recognize the CIC of a message it has received from the BSC.
Instructions
If several disturbances are generated check that the circuit in question has been created at both ends.
Cancelling
No cancelling

Strictly confidential
5
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

2725 ADJACENT CELL IDENTIFIER


CONFIGURATION ERROR
Meaning
Adjacent cell information has been defined incorrectly in the BSDATA (BSS Radio Network Configuration
Database). Either the MSC or the source BSC can detect the error during an external handover. When the
error has been detected, the handover attempt is interrupted.
Instructions
Check the adjacent cell information of the BTS in supplementary information field 1 in the BSDATA. If the
BSC has detected the error, supplementary information fields 3, 4 and 5 identify the cell that the MSC has
defined as the target cell.
Check the adjacent cell definitions with the MML command:
ZEAO:BTS=<BTS identification>;
Use the BTS's adjacent cell definitions to check the adjacent cell identification information (LAC and CI) of
either the adjacent cells in the target cell list or all adjacent cells in other BSSs.
Cancelling
Cancel the alarm with an MML command after correcting the fault as presented in INSTRUCTIONS. See
instructions on alarm administration.

Strictly confidential
6
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

7741 MEAN HOLDING TIME ABOVE DEFINED


THRESHOLD
Meaning
The mean holding time on the channel specified exceeds the operator-defined threshold during the
measurement period. The alarm is used to supervise the functioning of the traffic and signaling channels. It
reveals unreleased calls.
Information
Parameters, with their default values, affecting the alarm:
ZEEN:MAXHTT= maximum mean holding time for TCH (120 min)
MAXHTS= maximum mean holding time for SDCCH (30 min)
PRDMHT= length of TCH supervision measurement (240 min)
PRDMHS= length of SDCCH supervision measurement (60 min)
Cancelling
If the alarm does not require user actions, you can cancel it with the MML command EOR.
The system cancels the alarm when you lock and unlock the object in question, or, if the alarm requires no
user actions, the system cancels the alarm at the end of the measurement period during which the channel
that caused the alarm is allocated/ released normally.

Strictly confidential
7
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

7743 MEAN HOLDING TIME BELOW DEFINED


THRESHOLD
Meaning
Mean holding time on a channel is below the operator-defined minimum during the measurement period. The
alarm is used to supervise the functioning of traffic channels and to detect the possible faulty channels.
Instructions
Check that the parameters affecting the alarm are reasonable. The MML command EEO outputs the radio
network supervision parameter values and the EEN command modifies the parameter values.
Parameters, with their default values, affecting the alarm:
ZEEN:MINHTT = minimum mean holding time for a TCH (10 s)
PRDMHT = length of TCH supervision measurement (120 min)
CS = channel seizure threshold value (10)
Cancelling
If the alarm requires no user actions, you can cancel it with the MML command EOR.
The system cancels the alarm automatically in connection with the user's locking and unlocking commands,
or, if the situation is solved without user actions, after the current measurement period.
All supplementary fields are set to zero irrespective of the alarms cancelled manually or by the system.

Strictly confidential
8
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

7712 WORKING SDCCH CHANNEL RATIO BELOW


THRESHOLD
Meaning
The radio network configuration and failure management has detected that the ratio between the number of
SDCCH channels in the cell in normal working state (UNLOCKED-WORKING) and the number of traffic
channels in the cell in normal working state (UNLOCKED-WORKING) is below the defined threshold.
Only one alarm per cell is possible. Object of the alarm is the BTS which has the BCCH timeslot.
Instructions
Check why SDCCH channels in the cell in normal working state (UNLOCKED-WORKING) or traffic channels
(full and half rate) in the cell in normal working state (UNLOCKED-WORKING) are out of use. If the reason is
a faulty TRX, correct the fault. This increases the number of SDCCH channels in normal working state, and
the alarm is removed automatically.
The BSC-specific threshold value of the alarm can be changed with the MMI command EEQ. The new
threshold value takes effect as soon as the ratio of
the channels changes, for example, when the administrative state of the TRX is changed, or when the TRX's
operative state changes.
The following formula is used in calculating the ratio:
( number of WO and BL-SHD SDCCH channels / number of WO and BL-SHD traffic channels ) * 100
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.

Strictly confidential
9
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

7744 EXCESSIVE TCH INTERFERENCE


Meaning
During the supervision period, the TCH time slot has suffered excessive interference in idle mode that is
equal to or higher than the operator-defined alarm threshold percentage. That is, the interference in the time
slot has lasted longer than is acceptable. The interference level classified as excessive is defined by the
operator. The alarm is used to supervise the BTS traffic capacity.
Instructions
Measure the interference level on the traffic channel in question.
Parameters, with their default values, affecting the alarm:
ZEEN:HIFSHR= TCH interference level threshold value (50 )
HIFLVL= excessive interference level threshold value (4)
PRDHIF= TCH interference supervision measurement (120 min)
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when the fault has been corrected.

Strictly confidential
10
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

Agenda
Day1 22nd February 2012
Day Category
1
BSC overview

BSC overview

Description
Functional review of BSC
HSL check balance, configuration rules
Special Case crosstalk on FBSC Jambi2
PCU/NSEI dimensioning , configuration and limits
CDED, CDEF, CMAX
3273 GPRS/EDGE territory failure

Lunch Break
BTS special cases
OAM Alarm handling I

Strictly confidential
11
Nokia Siemens Networks

Presnter
CARE
(Narendra)

11:00-12:00

CARE
(Narendra, Martin)

12:00-13:00
EDGE CU vs Non-EDGE CU, EDGE, GTRX, CS3&4,,
and known special cases:
3265 UNEQUIPPED A INTERFACE CIRCUIT
2725 ADJACENT CELL IDENTIFIER CONFIGURATION
ERROR

Tea break
OAM Alarm handling I

Time
9:00 10:00

13:00-14:45
14:45-15:45

CARE
(Narendra)
CARE
(Narendra/Angga)

15:45-16:00
7741, 7743, 7712, 7744

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

16:00-17:30

CARE
Narendra, Martin)

Agenda
Day2 23th February 2012
Day Category
Recap &Test Day1
2

Description

Time

Presnter

Review Day 1 content & Test Together

9:00-9:15
9:15-10:00

ALL
CARE (Narendra)

FMR commissioning
Operation
&troubleshooting

OSS Scripts I
Lunch Break
OSS Scripts II

Mixed CU configuration, preferred BCCH,


10:00-11:00
TBF assignment vs MS class, HMC and SRA
features
ZEQO conversion to XLS
Create BTS
11:00-12:00
12:00-13:00

CARE
(Narendra, Martin)

Delete/create LAPD, split multiplexing BTS+,


Change BTS parameter
Modify EDAP, CDED, CDEF, CMAX,
Enable/disable GPRS/EDGE/ GTRX
Rehoming BTS with CM editor
Delete/Create ADJC
Convert to/from XML
Increase/ decrease LAPD size on FMR;

OSS (Yuri)

Tea Break
OAM Alarm handling II

Strictly confidential
12
Nokia Siemens Networks

13:00-15:00

OSS (Yuri)

15:00-15:15
7745, 7705, 7723, 7725, 7738, 7789, 7730
Tracing TBF traffic on PCU

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

15:15 - 17:30

CARE
(Narendra/ Angga)

Agenda
Day3 24th February 2012
Day Category
3
Recap &Test Day2
Optimization
Optimization
Lunch Break & Pray
Optimization

Description
Review Day 2 content & Test Together
BR to BS Parameter Mapping
BR to BS Parameter Mapping Q & A

Time
9:00-9:15
09:30-11.15
11.45-12.00
12:00-13.45

Presnter
ALL
NPO (Fani)
NPO (Fani & Daru)

Layering strategy for Bali


Modernization

13.45-15.30

NPO (Christian)

Tea Break
Optimization

15:30-15.45
Layering strategy for Bali
Modernization Q&A

Closing &feedback

Strictly confidential
13
Nokia Siemens Networks

15.45-17.00
17:00-17:30

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

NPO (Christian &


Daru)
All

Strictly confidential
14
Nokia Siemens Networks

CommonAbis closing workshiop/ Martin Holecek / 22nd -24th February 2012

Das könnte Ihnen auch gefallen