Sie sind auf Seite 1von 11

Resource Assessment Rules

Content
1.
.
.
.
.

Cell load monitoring


UL noise rise
Non-HS code resource assessment
Non-HS power resource assessment
Throughput

2.
3.

Node B CE resource assessment.


Node B IUB resource assessment.

Cell load monitoring


Index ID

SPI1

SPI2

SPI3

SPI4

Index Name

Average
utilization of nonHSDPA code
resources
(Average nonHSDPA TCP
Utilization Ratio or
maximum nonHSDPA TCP
Utilization Ratio)
& Average
Number of CellDch user in the
best cell
Average
throughput of a
HSDPA UE & The
best Cell Average
HSDPA Users
Uplink Noise Rise
& Average
Number of CellDch user in the

Expansion Threshold

C372490218 80%
(from Node B
V4.12.10.23P21)

Expansion Method

Multi-carrier/add NodeB

(KPI300829 55% or
KPI300830 90%) &
(C310030463 16)
Expand power
amplifier/add NodeB

(C310545121/
(C310545123*GR)
500kbps) & PI300844
16
(KPI300840 KPI300843
6 dB) & (C310030463
16)

HSPA+/Multi-carrier/add
NodeB

Multi-carrier/add NodeB

SPI is a logical index, which can be either 0 or 1. If an index reaches the threshold, its SPI is 1.
If the index does not reach the threshold, its SPI is 0.
The cell load is calculated as follows:
S_cell = SPI1 + SPI2 + SPI3 + SPI4
Where,
S_cell indicates the cell service load index.
"+" indicates the OR operation, and "" indicates the AND operation.
SPI3 determines whether an HSDPA service is overloaded. The HSDPA service is overloaded
only when SPI3 is 1.
SPI1 and SPI2 determine whether a non-HSDPA downlink service is overloaded. If SPI1 or S
PI2 is 1, the non-HSDPA downlink service is overloaded.
SPI4 determines whether the cell uplink is overloaded. If SPI4 is 1, the cell uplink is overloa
ded.
If S_cell is greater than 0, which indicates that the cell has a heavy service load, load optimi
zation and capacity expansion are required.
A larger S_cell value indicates heavier cell service load. The minimum value of S_cell is 0, an
d its maximum value is 4.
The following table lists the solutions to monitor cell resources.

Monitored
Object

Network-Wide Cell

Monitoring
granularity

Hour

Monitoring
period

7 24

Expansion
triggering
condition

If N (the duration of S_cell >


0, in hour) is equal to or
greater than 10, the cell is
added to the cell evaluation
list for load optimization and
capacity expansion.
A larger value of N indicates
greater capacity expansion
requirements.

>

Node B CE resource assessment


Node B CE Expansion Thresholds and Expansion Methods

Expansion
Indicator No.

Indicator Name

Expansion
Threshold

Expansion Method

SPI11

Average utilization of uplink


NodeB CE resource

SPI12

Average utilization of downlink


70%
NodeB CE resource

Expand the BPC


board
Expand the BPC
board

SPI13

Maximum utilization of uplink


NodeB CE resource

90%

Expand the BPC


board

SPI14

Maximum utilization of
downlink NodeB CE resource

90%

Expand the BPC


board

70%

ZTE Corporation. All rights


reserved.

>

NodeB-CE Expansion
According to the expansion threshold setting shown in previous Tabl
e, we use the expansion decision formula to assess the Node B load
and expansion demand.
S_nodeb_CE = SPI11 + SPI3+ SPI12 + SPI4
SPI11 =1 if UL CE > 70 %
SPI13 =1 if Max ul CE >90%
SPI12 =1 if DL CE > 70%
and SPI14 =1 if MAX DL CE >90%.
If the number of times that the S_nodeb_CE > 0 is equal or more tha
n 10 within one weak , the cell load reaches the expansion threshold.
Greater value of S_nodeb_CE means greater Node B expansion dema
nd. The minimum of S_node_CE is 0 and the maximum can be 4.

ZTE Corporation. All rights


reserved.

>

Monitoring
Monitoring Mode 1
Mode
Monitoring
Cell of the whole network
Object
Monitoring
Hour
Granularity
Monitoring
A week (7 24)
Cycle

Expansion
Trigger
Condition

Expansion threshold:
If N (the duration of S_Node
B_CE > 0, in hour) is equal to
or greater than 10, the Node
B is added to the evaluation
list for capacity expansion.

ZTE Corporation. All rights


reserved.

>

Node B IUB resource assessment.

SPI

Name

Expansion Threshold
(%)

IUB-SPI1

Average Iub Bandwidth


Utilization, UL data

70

IUB-SPI2

Average Iub Bandwidth


Utilization, DL data

70

IUB-SPI3

Maximum Iub Bandwidth


Utilization, UL data

90

IUB-SPI4

Maximum Iub Bandwidth


Utilization, DL data

90

ZTE Corporation. All rights


reserved.

>

According to the expansion threshold setting shown in previous Tabl


e, we use the expansion decision formula to assess the Node B load
and expansion demand.
S_nodeb_IUB = SPI1 + SPI3+ SPI2 + SPI4
SPI1 =1 if UL IUB > 70 %
SPI3 =1 if Max ul IUB >90%
SPI2 =1 if DL IUB > 70%
and SPI4 =1 if MAX DL IUB >90%.
If the number of times that the S_nodeb_IUB > 0 is equal or more th
an 10 within one weak , the cell load reaches the expansion threshol
d.
Greater value of S_nodeb_IUB means greater Node B expansion de
mand. The minimum of S_node_IUB is 0 and the maximum can be 4.

ZTE Corporation. All rights


reserved.

Thanks!

ZTE Corporation. All rights reserved.

Das könnte Ihnen auch gefallen