SDR Hardware and Fault Treatment

Brief Introduction

Chen Jie
2010-12-4

Internal Use Only

Director
y 09:00~11:00
1

Hardware Brief Introduction


2 LMT / Usage of LMT 11:10~11:30
3 13:30~15:30
Common Fault Treatment
4 RRU/RSU 11:30~12:00
Distinguish and exchange between
RRU/RSU
5 / Q&A(15:30~16:00)
6 6370 16:30~18:00
Demo of 6370

Internal Use Only

1 Hardware Brief Introduction


SDR Software Define Radio

SDR compare with the V2,3 BTS

The base band and RF unit are in the same


module in V2,3 BTS. ZTE SDR BBU and RU are
separated
lower power consumption

Internal Use Only

1 Hardware Brief Introduction

ZTE SDR structure


BBU B8200 +RRU(R8860) /RU(RSU60)
BBU: BaseBand Unit
RRU: Remote Radio Unit
RU: Radio Unit,
R8860

R8860E ;

RSU60

RSU60E

ZTE SDR station family


BS8900: Outdoor
BS8800: Indoor
BS8700: BBU indoor; RRU indoor or outdoor
BS8906: Outdoor; microcell

1 Hardware Brief Introduction

Internal Use Only

Pakistan SDR BTS Family and composing


8700:BS8900A-BC8910A Rack+R8860
8900:BS8900A-BC8910A Rack+RC8910A Rack
8800:BS8800 Rack
BC8910A Rack 1 BBU is in BTS RACK of outdoor LPU,
DDF, DCPD,FAN, to process Baseband function
RC8910A Rack 6 RSU RF unit in 1 rack of outdoor FAN
and DCPD to process RF function.
BS8800 Rack indoor cabinet BBU and RSU inside to
process baseband and RF function.
R8860 Remote RF unit, the same function as RSU to process
RF funtion.

8700 Schematic diagram

Internal Use Only

8900
Schematic
diagram

Internal Use Only

Internal Use Only

8800 Schematic diagram

1 Hardware Brief Introduction

BBU and Board

Internal Use Only

CC

Control and Clock Module

UBPG

Universal Baseband Processing Board


for GSM

GSM

FS

Fabric Switch Module

SA

Site Alarm Module

SE

Site Alarm Extension Module

NIS

Network Interface of STM-1

STM-1

PM

Power Module

FA

FAN Module

1 Hardware Brief Introduction

CC Board Introduction

Internal Use Only

1 Hardware Brief Introduction

UBPG Board Introduction

Internal Use Only

1 Hardware Brief Introduction

FS Board Introduction

Internal Use Only

1 Hardware Brief Introduction

SA Board Introduction

Internal Use Only

1 Hardware Brief Introduction

SA Board Jumper

Internal Use Only

E1 Cable

Internal Use Only

Internal Use Only

1 Hardware Brief Introduction

RSU /RRU Implements

Internal Use Only

1 Hardware Brief Introduction

Internal Use Only

RSU60 Module Introduction

RSU60

RSU60E
RSU60 Panel and Interfaces Reference BS8800
GU360(V4.00.21)
Indoor GSM&UMTS Macro Node B Hardware Description

RRU Introduction

Internal Use Only

RSU60 Panel and Interfaces Reference


BS8700 (V4.00.30) Hardware Description

1 Hardware Brief Introduction

OLP Power
Cable and Dry
Contact Cable

Internal Use Only

1 Hardware Brief Introduction

OLP Dry Contact Cable

Internal Use Only

Internal Use Only

Director
y 09:00~11:00
1

Hardware Brief Introduction


2 LMT / Usage of LMT 11:10~11:30
3 13:30~15:30
Common Fault Treatment
4 RRU/RSU 11:30~12:00
Distinguish and exchange between
RRU/RSU
5 / Q&A(15:30~16:00)
6 6370 16:30~18:00
Demo of 6370

Internal Use Only

2 Usage of LMT
Software install and login

Install Javainstall LMT softwarerun LMT


set IP
Set your PC IP login SDR BTS

BBU CC IP: 192.254.1.16


Computer IP: 192.254.1.*
JAVA folder

Internal Use Only

2 Usage of LMT
LMT folder

LMT run

Internal Use Only

2 Usage of LMT
Set Station IP

Internal Use Only

2 Usage of LMT
login

Internal Use Only

Director
y 09:00~11:00
1

Hardware Brief Introduction


2 LMT / Usage of LMT 11:10~11:30
3 13:30~15:30
Common Fault Treatment
4 RRU/RSU 11:30~12:00
Distinguish and exchange between
RRU/RSU
5 / Q&A(15:30~16:00)
6 6370 16:30~18:00
Demo of 6370

3 Common Fault Treatment

RU Alarm
RU common Alarm is as follows:
Board communication link interrupted
Outdoor lightning protection box alarm
Remote Antenna Vswr Alarm
Remote antenna over VSWR alarm
Improper DPD running status

Internal Use Only

3 Common Fault Treatment

Internal Use Only

RU Alarm
Board communication link interrupted

Advice
Maintenance team meet this alarm. First check
optical fiber, if not ok, check the RU or FS board.
Change order optical interface optical
fiber RU FS board

3 Common Fault Treatment

Internal Use Only

RU Alarm
Remote Antenna VSWR Alarm
Remote antenna over VSWR alarm

Advise
The same as V3 VSWR alarm If VSWR of antenna is ok,
need to change the RU.
If the alarm is over VSWR alarm, reset the RU after you do
the active, the alarm can disappear.

3 Common Fault Treatment

Internal Use Only

About RU Alarm
Outdoor lightning protection box alarm
If happening at SWAP time this alarm maybe due
to cable connection of LPB is wrong. If happening at
Maintenance time, this alarm may be due to LPB is
fault. Maybe need to change the LPB
Here is the cable connection Refer to this map

Improper DPD running status


This alarm will affect network quality Need to reset the
RU, otherwise should be change the RU.

3 Common Fault Treatment

Internal Use Only

About CC Alarm
Those alarm are due to the transmission. You should
check the transmission.
If you want to re-patch the EI SDR E1
Refer to this map

One thing more if Relay circuit fault appear on CC board the


alarm due to Lucid Channel is not working of eass. Check the MISSU
of MISU.

3 Common Fault Treatment

Internal Use Only

UBPG & FS Alarm


UBPG: Antenna data link error alarm
FS: Loss of Signal at Ir interface
If these two alarms appear RU should has
Board communication link interrupted alarm Check
the RU,the alarm will be disappear after RU running
normal

BBU Board & FCE & Fan Alarm

Board communication link interrupted


If BBU or FCE have Board communication link
interrupted alarm the board or FCE is fault. Change
the fault board

Fan alarm
If Fan alarm appear on FCE should change the Fan
or subrack 8700 Schematic diagram

Internal Use Only

3 Common Fault Treatment

Dry Contact Alarm


SDR Dry contact alarm have two parts One is from
FCE the other is from SA You can see the B/W
table
FCE dry contact alarm is from SDR itself. Like BC
door alarm water proof SMOG fault
SA dry contact alarm is like V3.If you want to repatch
the cableRegard this map
Board Type
FCE5

SA
SA

Alarm Code
Self-defined dry contact alarm(198084317)
Dry Contact Alarm Content:BC gate safety
signal
Self-defined dry contact alarm(198084317)
Dry Contact Alarm Content:Water Leakage
Alarm
Self-defined dry contact alarm(198084317)
Dry Contact Alarm Content:DG Low Fuel

Remark
From SDR itself

From EASS

3 Common Fault Treatment

Internal Use Only

SITE Reset: CC Board Reset (in configuration management)

Internal Use Only

Director
y 09:00~11:00
1

Hardware Brief Introduction


2 LMT / Usage of LMT 11:10~11:30
3 13:30~15:30
Common Fault Treatment
4 RRU/RSU 11:30~12:00
Distinguish and exchange between
RRU/RSU
5 / Q&A(15:30~16:00)
6 6370 16:30~18:00
Demo of 6370

Internal Use Only

4 Distinguish and exchange between RRU/RSU


You can see the difference between RSU60 and RSU60E. R8860
and R8860E outlook
RSU60E and R8860E are advanced RSU60 and R8860 RF unit.
They change each other should change the configuration of BTS and
BSC both end and reload the software.
Note: The RSU60 can not replace RSU60E or R8860 replace
R8860E

Internal Use Only

Director
y 09:00~11:00
1

Hardware Brief Introduction


2 LMT / Usage of LMT 11:10~11:30
3 13:30~15:30
Common Fault Treatment
4 RRU/RSU 11:30~12:00
Distinguish and exchange between
RRU/RSU
5 / Q&A(15:30~16:00)
6 6370 16:30~18:00
Demo of 6370

Internal Use Only

5Q&A

Internal Use Only

Director
y 09:00~11:00
1

Hardware Brief Introduction


2 LMT / Usage of LMT 11:10~11:30
3 13:30~15:30
Common Fault Treatment
4 RRU/RSU 11:30~12:00
Distinguish and exchange between
RRU/RSU
5 / Q&A(15:30~16:00)
6 6370 16:30~18:00
Demo of 6370

Internal Use Only

6 Demo of 6370