Water-cooled package

06/27/15

Production View

MGP-F35W/S
MGP-F60W/S
MGP-F80W/S
MGP-F100W/S
MGP-F120W/S
MGP-F135W/S

How to read the models?

1.Introduction

Features
Scroll compressor- Copeland
Discharge
Suction

Adopting the flexible scroll


compressor that is new designed,
the unit has advantages such as
high efficiency\low
noise\steady\reliable performance.

High temp. of oil keeps


the mucosity

Features
Adopting advanced multi
parallel multi-route system
design, each compressor
can start-up independently
according to the changes
of the systems load
Polyester coating panel,
bright and clean surface
with good quality feeling
and anti-corrosion feature.

Photograph of system

Photograph of system

Photograph of system

Water cooled package on the assembly


line

2.Shell & tube heat exchanger


Adopts shell & tube condenser and fin evaporator
with higher EER, bigger capacity, more energy
saving. (reduces the water jam, easy clean out,
difficult to be frozen injury)

3. System Principle
1.Water cooled package system circuitCooling

Direct heat exchange

Air cleaning system

Ambient

Heat exchange

Water-cooled
system

Water cooled system


Indirect heat
exchange

Cooling heat pump


circuit

System Chart
2.Refrigeration system
1). 60kW 80kW

System Chart
2). 100kW

System Chart
3). 120kW 135kW

4.Specification

Dimensions

Dimension:
Width 1420mm
Height 1839mm
Depth 1055mm
Packing :
Width 1604mm
Height 2047mm
Depth 1230mm
Net: 690(700)kg
Gross :723(733)kg
MGP-F60(80)W/S

Dimensions

Dimension:
Width 1912mm
Height 1839mm
Depth 1055mm
Packing :
Width 2152mm
Height 2047mm
Depth 1230mm
Net:820 (830 ,840) kg
Gross :870 (880,890)kg
MGP-F 100(120,135) W/S

Electric function
1.Summary:
Cooling and dehumidifying operation mode.
Universal protection function
Display and malfunction alarm function
Timer function

2.Control structure figure


Condensing water pump
cooling tower blower switch

In/out of control
Mode On
/Off
system
commend

Setting
temp. TS

switch,

Compressor
switch

Blower switch

Control board

Return
Temp. T1
Compressor
protection

current

Evaporator
temp.
T2A T2B
T2C

Pressure
protection
switch

Discharge temp.
protection switch

3.Malfunction code

4.Tough-screen

5.Air-volume pressure curve


10 3 m 3 /h

25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10

147

L120/S-C(810rpm)

L135/S-C(910rpm)

L100/S-C(740rpm)

L80/S-C(800rpm)
L60/S-C(710rpm)

Pa

If needed,we can supply the units with more air-volume and more
higher static pressure by change the fan motor.

6.Installation
1.Main unit
Check:
1). Required data
2). Installation location
3). Installation space

4) Installation foundation
5)Check items
Notice: After you have checked the unit, please take some
measures to protect it from being damaged.

2.Water system
1) Single unit

pressure
gauge

pipe
connecter

thermometer

Service
valve

pressure
thermometer
gauge
pipe
Adjusting valve
connecter

water
pump

Water-draniage
valve

Cooled
tower

water
filter

Service
valve

Water-recharge
valve

2).Multi units

close valve

close valve

close valve

Cooled tower
pipe
connecter

pressure
gauge

thermometer

service
valve

pressure
gauge thermometer

pipe
connecter

adjusting valve

water
pump

water-drainage valve

water
filter

Water-recharge valve

Service valve

3.Belt of fan motor

Notice: Over-loose or over-tight belt will damage the


system and cause the much big noise.

4. Electric installation
Unit power requirement :380V AC 50Hz
System working ambient condition : 17 38
Control system working ambient humidity: RH30%~RH95%
The temperature of water-inlet 33
Standard testing condition: Indoor 27 /19
Water inlet/ outlet temp 30 /35

2.Wiring select

Item

Power
supply

Model
MGP-F60W/S
MGP-F80W/S

MGP-F100W/S
MGP-F120W/S
MGP-F135W/S

380V
3N
50Hz

The thinnest
wire mm2
Ground
Power wire
wire

30m
25
10

Manual switch
A
Capacity

150
35

16

Creepage
Protector

Fuse

100

100
mA

3.Some special connection


1). Control Connection of cooled water pump :

2). Control Connection of fan motor of cooling


tower :

7.Debugging and maintenance


Debugging
1.Preparing work:
1).check water-quality, water-flow volume, water pressure.
It is forbade to start the water pump through the
main unit before the water system has been
installed well.
2). Max.water-flow volume(Open all of the water valve to
the max opening degree)
3).Wiring,system structure

2.Test running
1). Start the units by the LCD touch-screen, if there are
malfunction occurs, please eliminate the malfunction
before starting the units.
2). After the 30 minutes test running and the temperature of
inlet and outlet are stable, adjust the water-flow volume
to nominal value, and ensure the system work normally.
3). After the units operated, it is recommended to adjust the
water flow volume according to the operation current,
pressure, water system pressure, water-flow volume and
other parameters and real requirement to make sure the
unit can work well.

4). According to the real climate condition and refer to the


usage manual, optimize the units parameter setting,
and make the unit work in the best condition.
5). Please wait 4 minutes to restart the units after the
system stopped in order to avoid the system on/off so
frequent.

Below table shows the normal parameter of system:

Thank You!