How to Read the Model Name?


Function Code
R Remote Control
RA Remote Control with Electrical Heater
E with Electrical Heater
Nominal Air Volume(CFM)
-- Normal Static Pressure
Type Code
A 4 Way Cassette
C One Way Cassette

H High Static Pressure

B 4 Way Cassette (Compact)


T Duct

T1 127V 60 Hz Duct Type


T2 2nd Generation Duct Type
T3 New High-static Pressure Type
F1 Exposed Floor-stand Type (side air intake)
F2 Exposed Flood-stand Type (below air intake)
F3 Concealed Flood-stand Type
G Wall-mounted Type
H1 Exposed Ceiling and Floor Type (side air intake)
H2 Exposed Ceiling and Floor Type (back air intake)
H3 Concealed Ceiling and Floor Typy
Chilled Water Fan coil unit

Fan Coil

Cassette

Duct

Floor
Standing

Ceiling
and
Floor

Wall
mounted

Cassette

4-Way

4-Way

1-Way

4 pipes

MKC

MKD

Compact

MKA

MKB

Four-way
Cassette
Without EAH

Model List:

With EAH

MKA-600R

MKA-600RA

2100w

MKA-750R

MKA-750RA

2100w

MKA-850R

MKA-850RA

2700w

MKA-950R

MKA-950RA

2700w

MKA-1200R

MKA-1200RA

2700w

1.

Cooling capacity: 5.7~10.4kW;

2.

Electric auxiliary heater is optional (Assembled in factory);

3.

Build in water pump & water level switch (Standard);

4.

Maximum water inlet temp. is 70;

*EAH: Electric Auxiliary Heater

Four-way cassette
5.
6.
7.
8.

LED display in the panel;


Different color for the panel;
Fresh air function;
Reserve spaces for air side-outlet

3 Pre-cut hole
Send air to the nearby room

Variable color for the panel:

White

Grey

Black

Blue

Four-way
Cassette(60*60)

ct
Compa

New design

Without EAH*

Model List:

With EAH

MKB-300R

MKB-300RA

1000w

MKB-400R

MKB-400RA

1000w

MKB-450R

MKB-500R

1.

Cooling capacity: 3.0~5.5kW;

2.

Electric auxiliary heater is optional (Assembled in factory);

3.

Build in water pump & water level switch (Standard);

4.

Maximum water inlet temp. is 70

5.

Dimension: 580254580

*EAH: Electric Auxiliary Heater

One-way
Cassette
Without EAH

Model List:

With EAH

MKC-300R

MKC-300RA

1000w

MKC-400R

MKC-400RA

1000w

1.

Cooling capacity: 3040w, 3790w;

2.

Electric auxiliary heater is optional (Assembled in factory);

3.

Build in water pump & water level switch (Standard);

*EAH: Electric Auxiliary Heater

4-way pipe
Chill water pipe
1.

2 recycle system,2 pipes per system.

2.

Save a lot of energies in winter.

3.

Other function is same as 2 pipe


cassette.

Heat water pipe


Models

MKD600F

MKD750F

MKD850F

MKD950F

MKD1200F

MKD1500F

Cooling capacity(Btu/h)

17406

20239

21058

22867

31672

36109

Heating capacity
(Btu/h)

22765

26860

27509

29590

39761

43072

4-way pipe
Chill water pipe
1.

2 recycle system,2 pipes per system.

2.

Save a lot of energies in winter.

3.

Other function is same as 2 pipe


cassette.

Heat water pipe


Models

MKD300

MKD400

MKD500

Cooling
capacity(Btu/h)

10236

12624

15354

Heating capacity
(Btu/h)

13648

17401

20472

Accessories for
cassette

Accessories table:
EAH

Filter

Additional
drain pan

3-way
valve

Connection
kit

Controller

MKA

MKB

MKC

MKD

C: the accessories is optional, but it should be assembled in the factory;


S: the accessories is standard;
O: the accessories is optional, it can installed by the installer.

Accessories for
cassette
Block for air outlet hole:

Note: the block is only for four-way


cassette(80*80 type).
(Optional)

Accessories for
cassette
Additional drain pan (optional):

For 4-way cassette compact

For 4-way cassette

Accessories for
cassette

3-way valve

Connection Kit

(Optional)

(Optional)

Electronic coil
Valve

Controllers for cassette


Wireless
controller

Standard

Wired
controller

Optional

Central
controller

Optional

Note: NIM is necessary if use central controller to control the cassette.

Duct

2
Rows

3
Rows

4
Rows

HSP

4
Pipe

MKT2

MKT3

MKT4

MKT3H

MKT5

Duct (2-Rows without EAH)


MKT2, MKT2H
Model List:

1.
2.
3.
4.

12Pa

30(50)Pa

MKT2-200

MKT2H-200

MKT2-300

MKT2H-300

MKT2-400

MKT2H-400

MKT2-500

MKT2H-500

MKT2-600

MKT2H-600

MKT2-800

MKT2H-800

MKT2-1000

MKT2H-1000

MKT2-1200

MKT2H-1200

MKT2-1400

MKT2H-1400

Cooling capacity: 2~13Kw;


Air return plenums (including filter) are optional (Assembled in factory);
For MKT2H, 50Pa static pressure can be customized (in factory);
Pipe connection from left or right can be selected (in factory);

Duct (2-Rows with EAH)


MKT2-xxxE, MKT2H-xxxE
Model List:

1.
2.
3.
4.

12Pa

30(50)Pa

EAH

MKT2-200E

MKT2H-200E

500w

MKT2-300E

MKT2H-300E

650w

MKT2-400E

MKT2H-400E

1000w

MKT2-500E

MKT2H-500E

1000w

MKT2-600E

MKT2H-600E

1500w

MKT2-800E

MKT2H-800E

2000w

MKT2-1000E

MKT2H1000E

2000w

MKT2-1200E

MKT2H1200E

3000w

Cooling capacity: 2~13Kw;


MKT2HMKT2-1400E
Air return plenums (including filter) are standard;
1400E
For MKT2H, 50Pa static pressure can be customized (in factory);
Pipe connection from left or right can be selected (in factory);

3000w

Duct (3-Rows without EAH)

Model List:

1.
2.
3.
4.

12Pa

30(50)Pa

MKT3-200

MKT3H-200

MKT3-300

MKT3H-300

MKT3-400

MKT3H-400

MKT3-500

MKT3H-500

MKT3-600

MKT3H-600

MKT3-800

MKT3H-800

MKT3-1000

MKT3H-1000

MKT3-1200

MKT3H-1200

Cooling capacity: 2.2~12.1kW;


Air return plenums and air filter are standard;
For MKT3H, 50Pa static pressure can be customized (in factory);
Pipe connection from left or right can be selected (in factory);

Duct (4-Rows without EAH)


30Pa
MKT4H-200

Model List:

MKT4H-300
MKT4H-400
MKT4H-500
MKT4H-600
MKT4H-800
MKT4H-1000
MKT4H-1200
MKT4H-1500

1.
2.
3.

MKT4H-2000
Air volume: 2.2-17.9 kW
Air return plenums and air filter are standard;
Pipe connection from left or right can be selected (in factory);

Duct (4-Rows with EAH)


30Pa
MKT4H-200E

Model List:

MKT4H-300E
MKT4H-400E
MKT4H-500E
MKT4H-600E
MKT4H-800E
MKT4H1000E
MKT4H1200E

1.
2.
3.

Air volume: 2.2-17.9 kW


MKT4H1500E
Air return plenums and air filter are standard;
Pipe connection from left or right can be selected (in factory);
MKT4H2000E

High Static Pressure Duct (without EAH)


MKT3H Series

1.
2.
3.

Model List:

Static Pressure
MKT3H-800

70Pa

MKT3H-1000

70Pa

MKT3H-1200

70Pa

MKT3H-1400

70Pa

MKT3H-1600

100Pa

MKT3H-2000

100Pa

MKT3H-2200

100Pa

Cooling capacity: 8.8~19.9kW;


Air return plenums and air filter are standard;
Pipe connection from left or right can be selected (in factory);

High Static Pressure Duct (with


EAH)
MKT3H-xxxE Series
Model List:

1.
2.
3.

With EAH

EAH

Static
Pressure

MKT3H-800E

3Kw

70Pa

MKT3H1000E

3Kw

70Pa

MKT3H1200E

3Kw

70Pa

MKT3H1400E

3Kw

70Pa

MKT3H1600E

10K
w

100Pa

MKT3H2000E

10K
w

100Pa

Cooling capacity: 8.8~19.9kW;


Air return plenums and air filter are MKT3Hstandard; 10K
100Pa
2200E
w
Pipe connection from left or right can be selected (in factory);

4 Pipe ducted type

1 fan

4 fans

2 fans

1.For ESP,12Pa and 30Pa are optional.


2.The functions are same as 2 pipe ducted type.
Models

MkT5200

MkT5300

MKT5
-400

MKT5
-500

MKT5
-600

MkT5
-800

MkT51000

MkT51200

Cooling capacity(Btu/h)

6826

9215

12287

14676

17065

23208

26621

34812

Heating capacity
(Btu/h)

10239

13652

17747

19454

24573

32765

36860

46075

Accessories for duct


Accessories table:
EAH

MKT2
MKT3
MKT4
MKT3H
MKT5

Air return
Additional
plenum &Filter drain pan

3-way
valve

Connection
Controller
kit

No

Yes

No

No

Yes

No

Yes

No

C: the accessories are optional, but it should be assembled in the factory;


S: the accessories are standard;
O: the accessories are optional, it can be installed by the installer.

Accessories for duct


Air return plenums and electrical heaters:

The EAH must be installed in the factory;


The air return plenums must be installed in the
factory;
The duct with EAH must select air return
plenums, because the EAH is installed inside the
air return plenums;

Accessories for duct

3-way valve

Connection Kit

(Optional)

(Optional)

Electronic coil

Valve

Controllers for Duct


Thermostat.

For the units


without EAH

For the units


with EAH
Optional

Optional

Floor Standing

Exposed

Exposed

Curving panel

Concealed

Exposed

Exposed

Curving panel

Flat panel

Flat panel

Side intake

Bottom intake

Side intake

Bottom intake

MKF1

MKF2

MKF4

MKF5

MKF3

Floor-standing
Exposed type
Exposed

Model List:

MKF1: air return from front side


MKF2: air return from bottom ( standard with foot)

MKF1-150

MKF2-150

MKF1-250

MKF2-250

MKF1-300

MKF2-300

MKF1-400

MKF2-400

MKF1-450

MKF2-450

MKF1-500

MKF2-500

MKF1-600

MKF2-600

MKF1-800

MKF2-800

MKF1-900

MKF2-900

1.

Vertical installation on the floor- much more comfortable in heating mode;

2.

3-way valve can be built in the cabinet;

3.

Pipe connection can be left or right (installer change it).

Floor-standing
Exposed type New air outlet grill

Exposed

Model List:

Flat type air outlet grill

MKF4: air return from front side

MKF4-150

MKF5-150

MKF4-250

MKF5-250

MKF4-300

MKF5-300

MKF4-400

MKF5-400

MKF4-450

MKF5-450

MKF4-500

MKF5-500

MKF4-600

MKF5-600

MKF4-800

MKF5-800

MKF4-900

MKF5-900

MKF5: air return from bottom ( standard with foot)

The grill is modular design- easily removed and cleaned

Floor-standing
Concealed type

Concealed

Model List:

MKF3-150
MKF3-250
MKF3-300
MKF3-400
MKF3-450
MKF3-500
MKF3-600
MKF3-800
MKF3-900

1. Concealed installation- harmonic with the room

Accessories for Floor


standing

Accessories table:

Filter

Additional
drain pan

3-way
valve

Connection
kit

Controller

Exposed

Concealed

C: the accessories is optional, but it should be assembled in the factory;


S: the accessories is standard;
O: the accessories is optional, it can installed by the installer.

Accessories for Floor


standing

3-way valve, connection kit and additional drain pan


3-way valve-Optional
Connection kit-Optional

Controllers for Floor-standing


Thermostat (optional):

Optional

KJR-15B/E

Simple controller

KJR-15B/E(P)

With anti cold air function

The controller can be hided in the cabinet (only


for MKF1,2,4,5)
Optional

Ceiling and Floor

Exposed

Exposed

Curving panel

Curving panel

Side intake

Back intake

MKH1

MKH2

Concealed

MKH3

Ceiling-Floor
Exposed type

Model List:
Exposed
MKH1-150
MKH1-250
MKH1-300
MKH1-400
MKH1-450
MKH1-500
MKH1-600

air return from front side


1.

Vertical installation on the floor- much more comfortable in heating mode;

2.

3-way valve can be built in the cabinet;

3.

Pipe connection can be left or right (installer change it);

4.

Ceiling and Vertical installation for optional will be more convenience.

MKH1-800
MKH1-900

Ceiling-Floor
Exposed type

Model List:
Exposed
MKH2-150
MKH2-250
MKH2-300
MKH2-400
MKH2-450
MKH2-500
MKH2-600

air return from bottom


1.

Vertical installation on the floor- much more comfortable in heating mode;

2.

3-way valve can be built in the cabinet;

3.

Pipe connection can be left or right (installer change it);

4.

Ceiling and Vertical installation for optional will be more convenience.

MKH2-800
MKH2-900

Ceiling-Floor
Concealed type

Model List:

Concealed
MKH3-150
MKH3-250
MKH3-300
MKH3-400
MKH3-450
MKH3-500
MKH3-600
MKH3-800
MKH3-900

1. Concealed installation- harmonic with the room

Accessories for Ceiling and Floor


Accessories table:
Filter

Additional
drain pan

3-way
valve

Connection
kit

Controller

Exposed

Concealed

C: the accessories is optional, but it should be assembled in the factory;


S: the accessories is standard;
O: the accessories is optional, it can installed by the installer.

Accessories for Ceiling and Floor


3-way valve, connection kit and additional drain pan
3-way valve-Optional
Connection kit-Optional

Wall Mounted
MKG Series
MKG-250

Model List:

MKG-300
MKG-400
MKG-500
MKG-600

1.

Capacity: 2.24~4.5kW;

2.

3-way valve is inside the indoor unit;

3.

ON/OFF terminal for simple remote control ;

4.

Variable color for the panel;

5.

Multi direction of pipe connection.

Accessories for Wall


mounted

Accessories table:

MKG

3-way valve

Controller

Filter

See in next page

S: the accessories are standard;

Accessories for Wall


mounted

Filter list:

Bio filter

Silver lon filter

GTP filter

Deodorization filter

Anti- formaldehyde filter

Silver lon filter

HEAP filter

Three-tier healthy filter

HEPA air fresh filter

Anti-acarus filter

vitamin filter

Active carbon filter

Nano photocatalyst filter

Bio filter

Compound air fresh filter

Controllers for wall


mounted
Wireless

Standard

Wired controller

Optional

Remark: It doesnt need NIM when choose CCM.

Central controller

Optional

Air Handle Unit

Dual Skinned Horizontal Type


Dual Skinned Vertical Type
Dual Skinned Ceiling Suspended Type

Models List
Standard AHU

Dual Skinned (56 Models)


Horizontal

Vertical

Ceiling Suspended

Specification
Horizontal Type
Air Volume: 2,000 60,000m3/h
Model: MKW2-020W MKW2-600W

Vertical Type
Air Volume: 2,000 60,000m3/h
Model: MKW2-020L MKW2-600L

Ceiling Suspended Type


Air Volume: 2,000 15,000m3/h
Model: MKS020D1 MKS150D1

Air Out Type


1

V e rt ic al

H o r iz o n t al

Ceiling sus pended

Thank You!
http://www.mideacac.com
http://www.mideaaircon.com

GD Midea Commercial Air-Conditioning Equipment Co., Ltd.

Das könnte Ihnen auch gefallen