SITE ANALYZER

Bird SA 2500 Ex

Site analyzer

Bird Electronics SA 2500 Ex


N
O
/O

on
al

M
od

Co
nf
ig

on

Fu
nc
ti

CHRG

r
Ma
ker

Bu
tt o
ns

Selection Buttons

FF

PWR

ti
ibra
Cal

Site analyzer

Display

-/+

ESC

Enter

Bird Electronics SA 2500 Ex


Top View

Charging Port

Printer Port

RS232 Port

Site analyzer

RF Antenna Port

VSWR Measurement

h
itc
w
S

Bird Electronics -Site Analyzer


Model No. 2500 Ex
PWR

Operating Frequency: 780 2500 MHz

M
od

Co
nf
ig

ti
ibra
Cal
on

Site analyzer

r
Ma
ker

-/+

CHRG

ESC

Enter

ON

VSWR Measurement
Screen displays the mode in which it was switched off at latest use.

Fault location

1.5
Save /Recall

Limit Test
OFF

VSWR

Autoscale

PWR

Hold

CHRG

1.0

M
od

Site analyzer

r
Ma
ker
tion n
ibra atio
Cal alibr
C

g
an
h
C

de
o
eM

Co
nf
ig

Distance(M)

Print

-/+

450

ESC

Enter

VSWR Measurement
After pressing Mode, Screen displays the Mode Options .
Pres
s
Mode
Measure Match
Fault Location
Measure Power
PWR
CHRG

Utility

M
od

r
Ma
ker
tion n
ibra atio
Cal alibr
C

Site analyzer

Co
nf
ig

-/+

ESC

Enter

VSWR Measurement

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
780

Print

Frequency(MHz)

2500

Calibration Full

s
Pres
M
od

r
Ma
ker
tion n
ibra atio
Calalibr
C

Site analyzer

Co
nf
ig

-/+

Set the freq


range
ESC

Enter

VSWR Measurement

Measure Match mode


Freq
Limit

Start

780

MHz
PWR

Stop

M
od

r
Ma
ker
tion n
ibra tio
Cal alibra
C

Site analyzer

Co
nf
ig

2500

CHRG

MHz

-/+

ESC

Enter

VSWR Measurement

Measure Match mode


Freq
Limit

Start

890

MHz
PWR

Stop

M
od

r
Ma
ker
tion n
ibra tio
Cal alibra
C

Site analyzer

Co
nf
ig

960

CHRG

MHz

-/+

ESC

Press to
select start
freq

Enter

VSWR Measurement

Measure Match mode


Freq
Limit

Start

890

MHz
PWR

Stop

M
od

r
Ma
ker
tion n
ibra tio
Cal alibra
C

Site analyzer

Co
nf
ig

960

CHRG

MHz

-/+

ESC

Press to
select stop
freq

Enter

10

VSWR Measurement
Freq range is changed but calibration is not done.

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890

Print

Frequency(MHz)

960

Calibration off

M
od

Site analyzer

r
Ma
ker
tion n
ibra tio
Cal alibra
C

s
Pres

Co
nf
ig

-/+

ESC

Calibration
must be full
before
measurement

Enter

11

VSWR Measurement

Connect
open
connector to
RF ant port

Calibration
Open

s
Pres

1.5

VSWR

Short
Load

PWR
CHRG

1.0
890

Frequency(MHz)

960

Calibration off

M
od

Co
nf
i

r
Ma
ker
ttiioonn n
iibbrraa tio
CCaall alibra
C

Site analyzer

3
-/
+

ESC

Enter

12

VSWR Measurement

Calibration
Open

s
Pres

Done

1.5

VSWR

Short
Load

PWR
CHRG

1.0
890

Frequency(MHz)

960

Calibration off

M
od

Co
nf
i

r
Ma
ker
ttiioonn n
iibbrraa tio
CCaall alibra
C

Site analyzer

3
-/
+

ESC

Enter

13

VSWR Measurement

Connect
short
connector to
RF ant port

Calibration
Open

Done

1.5

VSWR

Short

s
Pres

Load

PWR
CHRG

1.0
890

Frequency(MHz)

960

Calibration off

M
od

Co
nf
i

r
Ma
ker
ttiioonn n
iibbrraa tio
CCaall alibra
C

Site analyzer

3
-/
+

ESC

Enter

14

VSWR Measurement

Calibration
Open

Done

1.5

VSWR

Short Done
Load

PWR
CHRG

1.0
890

Frequency(MHz)

960

Calibration off

M
od

Co
nf
i

r
Ma
ker
ttiioonn n
iibbrraa tio
CCaall alibra
C

Site analyzer

3
-/
+

ESC

Enter

15

VSWR Measurement

Connect
Load
connector to
RF ant port

Calibration
Open

Done

1.5

VSWR

Short Done
Load

s
Pres

PWR
CHRG

1.0
890

Frequency(MHz)

960

Calibration off

M
od

Co
nf
i

r
Ma
ker
ttiioonn n
iibbrraa tio
CCaall alibra
C

Site analyzer

3
-/
+

ESC

Enter

16

VSWR Measurement
Now Site Analyzer is ready for VSWR measurement.

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890

Print

Frequency(MHz)

960

Calibration Full

M
od

r
Ma
ker
tion n
ibra atio
Calalibr
C

Site analyzer

Co
nf
ig

-/+

ESC

Calibration is
changed to
full

Enter

17

Connect Adopter
and than jumper
cable to RF ant
port

Jumper
Jumper
Cable
Cable

VSWR Measurement

Measure Match mode


Save /Recall

1.5

s to
R
Pres re VSW
u
s
me a

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890

Print

Site analyzer

Frequency(MHz)
Calibration Full

3
-/
+

960

ESC

Enter

18

Jumper
Jumper
Cable
Cable

VSWR Measurement

To read the accurate value set the marker.

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890

Print

s
Pres

Site analyzer

Frequency(MHz)
Calibration Full

3
-/
+

9600

ESC

Enter

19

Jumper
Jumper
Cable
Cable

VSWR Measurement

To read the accurate value set the marker.

Activate Marker
M1

1.5

OFF
VSWR

ivate
t
c
a
s to
Pres r
e
mark

Triangular

PWR
CHRG

1.0
780

Site analyzer

Frequency(MHz)
Calibration Full

3
-/
+

2500

ESC

Enter

20

Jumper
Jumper
Cable
Cable

VSWR Measurement

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890

Print

Site analyzer

Frequency(MHz)
Calibration Full

3
-/
+

ESC

960

the k
t
f
i
sh e pea
o
t
ss at th
e
r
P rker
ma

Enter

21

Jumper
Jumper
Cable
Cable

VSWR Measurement
Marker reads high VSWR. To locate the fault go to fault
location mode.

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890
M1 1.47

Print

Site analyzer

Frequency(MHz)
940 Calibration Full

3
-/
+

960

ESC

Enter

22

Jumper
Jumper
Cable
Cable

VSWR Measurement

Measure Match mode


Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
890
M1 1.47

Print

nge
a
h
c
s to
Pres de
o
the m

Site analyzer

Frequency(MHz)
940 Calibration Full

3
-/
+

960

ESC

Enter

23

Mode
1.5

Fault Location
Measure Power

VSWR

t
selec
o
t
s
Pres de
o
the m

Measure Match

Jumper
Jumper
Cable
Cable

VSWR Measurement

PWR
CHRG

1.0
890
M1 1.47

Utility

Site analyzer

Frequency(MHz)
940 Calibration Full

3
-/
+

960

ESC

Enter

24

Jumper
Jumper
Cable
Cable

VSWR Measurement

Fault Location

Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
0

Print

t
selec
o
t
s
Pres de
o
the m

Site analyzer

Meters
Calibration Full

3
-/
+

450

Enter the require


d
distance

ESC

Enter

25

Jumper
Jumper
Cable
Cable

VSWR Measurement

Fault Location

Distance

1.5

VSWR

Scale

PWR

Site analyzer

Min

Max

450

CHRG

1.0
0

Meters
Calibration Full

3
-/
+

450

ESC

Enter

Press to select
Max

26

Jumper
Jumper
Cable
Cable

VSWR Measurement

Fault Location

Distance

1.5

VSWR

Scale

PWR

Site analyzer

Min

Max

45

CHRG

1.0
0

Meters
Calibration Full

3
-/
+

450

Press to go back
To fault mode
ESC

Enter

27

Fault Location

Save /Recall

s to
Pres h trace
s
refre

Jumper
Jumper
Cable
Cable

VSWR Measurement

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
0

Print

Site analyzer

Co
nf
i

r
Ma
ker
on
rati tion
alaiblibra
CC

t
to se
s
s
e
Pr
rker
a
m
the

M
od
e

Meters
Calibration Full

3
-/
+

45

ESC

Enter

28

Jumper
Jumper
Cable
Cable

VSWR Measurement

Activate Marker
M1

r
s to
Pres te marke
a
activ

1.5

VSWR

OFF
Triangular

PWR
CHRG

1.0
0

Site analyzer

Co
nf
i

r
Ma
ker
on
rati tion
alaiblibra
CC

M
od
e

Meters
Calibration Full

3
-/
+

45

ESC

Enter

29

Jumper
Jumper
Cable
Cable

VSWR Measurement

Fault Location

Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
0
M1 5

Print

Site analyzer

Co
nf
i

r
Ma
ker
on
rati tion
alaiblibra
CC

M
od
e

Meters
1.24 Calibration Full

3
-/
+

45

Press to shift
Marker to peak

ESC

Enter

30

s to
Pres the trace
Save

Jumper
Jumper
Cable
Cable

VSWR Measurement

Fault Location

Save /Recall

1.5

VSWR

Autoscale
Limit Test
OFF

PWR

Hold

CHRG

1.0
0

Print

M1 25

Site analyzer

Co
nf
i

r
Ma
ker
on
rati tion
alaiblibra
CC

M
od
e

Meters
1.47 Calibration Full

3
-/
+

45

Press to shift
Marker to peak

ESC

Enter

31