Beruflich Dokumente
Kultur Dokumente
At
T S ALLOYS LIMITED
SAFETY ACHIEVEMENTS
Du-Pont Structure was incorporated under the leadership of Chief of
Corporate Safety on 4 th of May 2011.
Certification of ISO 9001: 2008, ISO 14001: 2004, OHSAS 18001: 2007
by Indian Register Quality Systems was attained on 10 th November
2011.
Implementation of 5S and Kaizen from 5th September 2012
T S Alloys received Kalinga Safety Award for best practices in Safety,
Health and Environment on 14 th September 2012.
TSAL received best safety performance in TIS Group award for its best
practices in safety from M.D Tata Steel Ltd on 30 November 2012.
implementation of LOTO {lock out tag out} process was initiated from
18th March 2013.
MD
GM
Asst.
Manager
(Admin &
Services)
(Safety &
Environment)
On-site Emergency
An on-site emergency is caused by an accident that takes place in an
industrial industry and the effects are confined to the factory premises
involving only the people working in the factory.
IDENTIFICATION OF HAZARD
Hazard is in fact the characteristics of a system/plant/storage that
has the potential for an accident and risk is the probability of
occurrence of hazard.
Hazard identification is of prime significance for the quantification
of risk and for cost-effective control of accidents in any industrial
installation.
Hazards are mostly manifested in the form of fire / explosion / toxic
release.
Area/Activity
Hazard
Impact
Furnace Oil
Liquid Oxygen
Leakage to atmosphere
Coal
LIQUID OXYGEN
LIQUID OXYGEN There is a liquid oxygen storage tank. Release of
oxygen from pipeline or oxygen storage tank accidentally may pose serious
fire hazards (leakage through 25mm diameter hole).
Leakage of liquid oxygen from oxygen storage plant will vigorously
accelerate the combustion or explosion of organic or other oxidizable
material.
Control measures
The liquid oxygen dispersion model has been prepared on the basis of
guassion model.
Emergency procedures are to be prepared including the event of
spillage of the cryogenic fluid.
emergency procedures are prepared in conjunction with the emergency
services or fire brigade and the local conditions are considered.
The procedures shall be readily available to all personnel involved,
regularly practiced and checked periodically.
COAL FIRE
COAL FIRE - Self-heating is the process whereby a coal particle
undergoes chemical and physical reactions that generate heat within the
coal particle.
Control Measure
Coal should not be stacked in the yard more than the process
requirement for a stipulated number of days.
As far as possible, coal must not be stored for more than 3 months.
Where it is unavoidable to store it for a longer period, the top and
sides of each heap/ stack must be well sealed with oil or other suitable
medium.
Coal handling unit/Agency shall provide adequate fire-fighting measure
to avoid any fire or related hazards.
Works Main Controller shall declare normalcy after full control of the
emergency.
Works Main Controller shall direct the auxiliary team leader (ATL) /
security gate to blow, all clear siren continuously for one minute.
THANK