Sie sind auf Seite 1von 89

Security Level:

OptiX RTN 900 V1R2


System Hardware

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Preface
The

OptiX RTN 900 is a new generation split

microwave transmission system developed by Huawei.


It can provide a solution that is integrated with the TDM
microwave, Hybrid microwave, and Packet microwave
based on the network requirements. RTN 900 V1R1
support pure packet microwave, and RTN 900 V1R2
support TDM microwave and Hybrid microwave.
This

course describes the network position, system

architecture, and hardware structure of the OptiX RTN


900.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 2

References
OptiX

RTN 910 V100R002 hardware

description documentation
OptiX

RTN 950 V100R002 hardware

description documentation

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

Target
After

completing this course, you should be

familiar with the following information:


Network

position and networking application of the

OptiX RTN 900 V1R2


System

architecture of the OptiX RTN 900 V1R2

Hardware

structure of the OptiX RTN 900 V1R2

Functions

and applications of each board on the

OptiX RTN 900 V1R2

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

Contents
Network Position and Networking
Application
System Architecture
Hardware Structure
Boards

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

Network Position
The OptiX RTN 900 is a new generation split microwave transmission system developed by Huawei. It

can provide a seamless microwave transmission solution for a mobile communication network or
private network.
The OptiX RTN 900 products are available in two types: OptiX RTN 910 and OptiX RTN 950. The IDU

of the OptiX RTN 910 is 1U high and supports one or two IF boards. The IDU of the OptiX RTN 950 is
2U high and supports one to six IF boards. The users can choose an appropriate type based on the
actual requirements.
The OptiX RTN 900 provides several types of service interfaces and facilitates installation and flexible

configuration. It can provide a solution that is integrated with the TDM microwave, Hybrid microwave,
and Packet microwave based on the network requirements. It supports the smooth upgrade from the
TDM microwave to the Hybrid microwave, and from the Hybrid microwave to the Packet microwave.
The solution can evolve based on the service changes that occur due to radio mobile network
evolution. Thus, this solution can meet the transmission requirements of not only 2G and 3G networks,
but also future LTE and 4G networks.

RTN 900 V1R1 support pure packet microwave, and RTN 900 V1R2 support TDM microwave and
Hybrid microwave.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 6

Network Application TDM microwave


transmission solution

E1

E1

E1

E1
STM-1/E1

E1

Regional Backhaul
Network

E1

E1
E1
E1

OptiX

RTN

900

E1

BTS

BSC

When the OptiX RTN 910 supports the microwave transmission in three directions or more, you can adopt

the NE cascading mode or use the OptiX RTN 950, which has more powerful functions.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

Network Application Hybrid microwave


transmission solution

FE

E1
E1

FE
E1

E1
STM-1/E1
Regional Backhaul
Network

E1
FE/GE

GE
E1
FE
E1

OptiX

RTN

900

NodeB

BTS

RNC

BSC

When the OptiX RTN 910 supports the microwave transmission in three directions or more, you can adopt

the NE cascading mode or use the OptiX RTN 950, which has more powerful functions.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

Contents
Network Position and Networking
Application
System Architecture
Hardware Structure
Boards

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 9

System ArchitectureTDM Microwave


The SDH/PDH microwave equipment consists of a series of functional units, including the

service interface unit, timeslot cross-connect unit, IF unit, control unit, clock unit, auxiliary
interface unit, fan unit, power unit, and ODU.
Service
interface
unit

Accesses E1 signals.
Accesses STM-1 signals.

Service
switching
unit

Provides the cross-connect


function and grooms TDM
services.

IF unit

Maps service signals to


microwave frame signals and
demaps microwave frame
signals to service signals.
Performs conversion between
microwave frame signals and
IF analog signals.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 10

System ArchitectureHybrid Microwave


The Hybrid microwave equipment consists of a series of functional units, including the

service interface unit, timeslot cross-connect unit, packet switching unit, IF unit, control
unit, clock unit, auxiliary interface unit, fan unit, power unit, and ODU.
Service
interface
unit

Accesses E1 signals
Accesses STM-1 signals
Accesses Ethernet signals.

Timeslot
crossconnect
unit

Provides the cross-connect


function and grooms TDM
services.

Packet
switching
unit

Processes Ethernet services


and forwards packets.

IF unit

Maps service signals to


microwave frame signals and
demaps microwave frame
signals to service signals
Performs conversion between
microwave frame signals and IF
analog signals.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

RTN 910Service Signal Processing Flow

SDH/PDH Microwave

Hybrid Microwave

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 12

RTN 950 Service Signal Processing Flow

SDH/PDH Microwave

Hybrid Microwave

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 13

Contents
Network Position and Networking
Application
System Architecture
Hardware Structure
Boards

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 14

Hardware Structure
RTN 900 series

The RTN 900 is of a split structure,

Universal AOC

IDU 910

IDU 950

consisting of the IDU and the AOC.


The AOC is universal. The IDU is
classified into the IDU 910 and IDU
950.
Boards are inserted in the IDU. The
IDU can realize different functions by
housing different boards.

Uniform platform and standard design:


Two types of case-shaped equipment: IDU 910 (1U) and IDU 950 (2U)
The IDU 910 and IDU 950 support the same IF boards and service interface boards.
Different system control and communication unit, switching unit, and clock unit integrated boards are
used on the IDU 910 and IDU 950.
Switching capacity of the IDU 910 4.2G CSHA/CSHB/CSHC
Switching capacity of the IDU 950 10G CSH
Cross-Connect capacity of IDU 910: 88 VC-4 CSTA
Cross-Connect capacity of IDU 910: 3232 VC-4 CSTA
The power supply boards and fan boards used on the IDU 910 and IDU 950 are of different functional
versions.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 15

Hardware Structure IDU 910


A maximum of two microwave

directions are supported.


The 1+1 HSB/SD/FD is supported.
The 2+0 configuration is supported.
The XPIC is supported.
442 mm (width) x 220 mm (depth) x 44.45 mm (height)

Paired slots
for housing the service
interface boards or IF boards

"EXT" represents an extended slot, which can house an IF board or

a service interface board.


All the boards except the power supply board support hot
swapping.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 16

Hardware Structure IDU 950


2U high
A maximum of six microwave directions

are supported.
The 1+1 HSB/SD/FD is supported.
The N+0 configuration (N5) is supported.
The N+1 configuration (N5) is supported.
The XPIC is supported.
Paired slots

442 mm (width) x 220 mm (depth) x 88.9 mm (height)

Paired slots

Integration card (1+1)

Power(1+1)

Paired slots

"EXT" represents an extended slot, which can house an IF board or a service interface board.
All the boards except the power supply board support hot swapping.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 17

Contents
Network Position and Networking
Application
System Architecture
Hardware Structure
Boards

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 18

Contents

Boards

TDM system control, cross-connect, and timing board

CSTA
CST

Hybrid system control, cross-connect, and timing board


IF board
Service interface board
Auxiliary and management interface board
Power supply board and fan board

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 19

CSTA Functions and Features


The CSTA provides the full time division cross-connection, system control and

communication, and clock processing functions. In addition, the CSTA provides PDH/SDH
service interfaces, auxiliary interfaces, and management interfaces.
Grooms service signals between boards. Supports full time division cross-connections at the VC-

12, VC-3, or VC-4 level, which are equivalent to 8x8 VC-4s.


Provide two STM-1 optical interfaces and sixteen E1 service interfaces.
Provides one Ethernet NM interface and NM serial interface.
Provides one NE cascade interface.
Supports one input and one output of the external clock. / Bypass E1 service interface.
Provides one asynchronous / synchronous data interface.
Provides one three-input and one-output external alarm interface.
Provides one Orderwire interface.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 20

CSTAFunctional Modules
Functional modules:
The CSTA comprises the

system control and


communication unit,
cross-connect unit, clock
unit, service processing
unit, auxiliary interface
unit, and power supply
unit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 21

CSTA Slot allocation

CSTA boards are inserted in slots 1 and 2 in the IDU 910 chassis.
The CXPAR/CXPBR boards can be inserted only in slots 1 and 2 in the IDU 910 chassis.
The CXPAR/CXPBR boards cannot be inserted in the IDU 950 chassis.

According to the functional units, the CSTA is mapped into the logical system control and
communication board (CSTA), logical auxiliary and management board (AUX), and
logical service boards (SL1D and SP3S) on the NMS.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 22

CSTA Interfaces
external clock/ Bypass E1
service interface

Buttons
Indicators

NE cascade
interface

NM interface/NM
serial interface

Orderwire phone
interface (RJ-45
connector)

Synchronous/A
synchronous
data interface
Alarm input/output
interface

STM-1 optical
interfaces

E1 (1-16)
interface

NOTE:

The external clock interface and wayside E1 interface are combined into one interface. This interface can transparently transmit
the DCC byte, orderwire overhead byte, and synchronous/asynchronous data service overhead byte. One interface, however,
can implement only one of the three functions: external clock interface, wayside E1 service, and transparent transmission of the
overhead byte.
The 64 kbit/s synchronous data interface can transparently transmit the orderwire byte. One interface, however, can implement
only one of the two functions: 64 kbit/s synchronous data interface and transparent transmission of the orderwire byte.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 23

CSTAIndicators
Indicator

Color

State

Description

On (green)
STAT indicator

The board is working normally.

On (red)

The board hardware is faulty.


The board does not start to work, is not
created, or is not powered on.

Off

PROG indicator

On (green)

The upper layer software is being initialized or


the software is working normally.

On (red)

The memory self-check fails, the upper layer


software fails to be loaded, the logic file is lost,
or the upper layer software is lost.

On for 100 ms
(green) and off for
100 ms repeatedly

The information is being written to the flash or


the software is being loaded.

On for 300 ms
(green) and off for
300 ms repeatedly

When the board is being powered on or being


reset, the board software is in BIOS boot state.

On for 100 ms (red)


and off for 100 ms
repeatedly

The BOOTROM self-check fails or the loading


of the FPGA fails.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 24

CSTAIndicators
Indicator

Color

SYNC indicator

State
On (green)
On (red)
On (green)

SRV indicator

The clock is operating normally.


The clock source is lost or is switched.
The services are working normally and no
alarms occur in the services.

On (red)

A critical or major alarm occurs in the


services.

On (yellow)

A minor or remote alarm occurs in the


services.

Off
On (red)

LOS 1
Off
On (red)

LOS 2
Off

HUAWEI TECHNOLOGIES CO., LTD.

Description

There is no power supplied to the system.


The first optical interface on the line reports
the R_LOS alarm.
The first optical interface on the line does not
report the R_LOS alarm.
The second optical interface on the line
reports the R_LOS alarm.
The second optical interface on the line does
not report the R_LOS alarm.

Huawei Confidential

Page 25

CSTAButtons
Button

Description

CF RCV button

Used to restore the configuration


data from the CF card.

RST button

Used to perform a warm reset on


the equipment.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 26

CSTFunctions and Features

The CST provides the time division cross-connection, system control and communication,

and clock processing functions. In addition, the CST provides the auxiliary interfaces and
management interfaces.
Grooms TDM service signals between boards. Supports full time division cross-connections at the

VC-12, VC-3, or VC-4 level, which are equivalent to 32x32 VC-4s.


Provides one Ethernet NM interface/NM serial interface .
Provides one NE cascade interface.
Support one external clock interface/ wayside E1 interface.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 27

CST Functional Modules


Functional modules:
The CST comprises the
system control and
communication unit,
cross-connect unit, clock
unit, and power supply
unit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 28

CSTSlot allocation
The CST boards can be inserted in slots 7 and 8 and form a 1+1 protection group.

Note
The CST boards can be inserted only in slots 7 and 8 in the IDU 950 chassis and form a

1+1 protection group.


The CST board cannot be installed in the IDU 910 chassis.
The logical slot of the CST on the NMS should be the same as the physical slot.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 29

CST Interfaces
Indicators
Button

NM cascade
interface

External clock
interface/The first time
interface/The wayside E1
interface

NM interface/NM
serial interface

The second time interface

Note

The external clock interface and wayside E1 interface are combined into one interface. This interface can transparently
transmit the DCC byte, orderwire overhead byte, and synchronous/asynchronous data service overhead byte. One interface,
however, can implement only one of the three functions: external clock interface, wayside E1 service, and transparent
transmission of the overhead byte.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 30

CSTIndicators
Indicator

Color

State

Description

On (green)
STAT indicator

The board is working normally.

On (red)

The board hardware is faulty.


The board does not start to work, is not
created, or is not powered on.

Off

PROG indicator

On (green)

The upper layer software is being initialized or


the software is working normally.

On (red)

The memory self-check fails, the upper layer


software fails to be loaded, the logic file is lost,
or the upper layer software is lost.

On for 100 ms
(green) and off for
100 ms repeatedly

The information is being written to the flash or


the software is being loaded.

On for 300 ms
(green) and off for
300 ms repeatedly

When the board is being powered on or being


reset, the board software is in BIOS boot state.

On for 100 ms (red)


and off for 100 ms
repeatedly

The BOOTROM self-check fails or the loading


of the FPGA fails.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 31

CSTIndicators
Indicator

Color

SYNC indicator

State
On (green)
On (red)
On (green)

SRV indicator

Description
The clock is operating normally.
The clock source is lost or is switched.
The services are working normally and no
alarms occur in the services.

On (red)

A critical or major alarm occurs in the


services.

On (yellow)

A minor or remote alarm occurs in the


services.

Off

There is no power supplied to the system.

On (green)

The board is in the active state in the 1+1


protection system.
The board is already activated in the
unprotected system.

ACT
Off

The board is in the standby state in the 1+1


protection system.
The board is not activated in the unprotected
system.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 32

CSTButtons
Button

Description

CF RCV button

Used to restore the configuration data from the CF card.

RST button

Used to perform a warm reset on the equipment.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 33

Contents

Boards
TDM system control, cross-connect, and timing board
Hybrid system control, cross-connect, and timing board

CSHA/CSHB/CSHC
CSH

IF board
Service interface board
Auxiliary and management interface board
Power supply board and fan board

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 34

CSHA/ CSHB/CSHCFunctions and Features

The CSHA/CSHB/CSHC provides the 4.2 Gbit/s packet switching, full time division cross-connection, system control
and communication, and clock processing functions. In addition, the CSHA/CSHB/CSHC provides FE/GE interfaces,
PDH/SDH interfaces, auxiliary interfaces, and management interfaces.

Support Packet Switch, Provides the 4.2 Gbit/s packet switching capability.

Supports full time division cross-connections at the VC-12, VC-3, or VC-4 level, which are equivalent to 8x8 VC4s.

Provides TDM service interfaces: The CSHA provides sixteen 75-ohm/120-ohm E1 data interfaces. The CSHB
provides thirty-two 75-ohm/120-ohm E1 data interfaces. The CSHC supports sixteen 75-ohm/120-ohm E1 data
interfaces and two STM-1 optical interfaces. The two STM-1 optical interfaces use the SFP optical modules.

Provides Eth service interfaces: The CSHA provides two FE electrical interfaces and two GE electrical
interfaces. The two GE electrical interfaces can also transmit FE electrical signals. The CSHB provides two FE
electrical interfaces and two GE electrical interfaces. The two GE electrical interfaces can also transmit FE
electrical signals. The CSHC provides two FE electrical interfaces and two GE optical interfaces. The two GE
optical interfaces use the SFP optical modules.

Provides one Ethernet NM interface/ NM serial interface.

Provides one NE cascade interface.

Provides one input and one output of the external clock. / Bypass E1 service interface.

Provides one asynchronous data interface / synchronous data interface .

Provides one three-input and one-output external alarm interface.

Provides one Orderwire interface.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 35

CSHA/ CSHB/CSHCFunctions and Features

The differences between the CSHA, CSHB, and CSHC are with regard to the types and number
of service interfaces.

CSHA 2* FE(e) +2*GE(e)+16*E1

CSHB:2* FE(e) +2*GE(e)+32*E1

CSHC:2* FE(e) +2* GE(o)+16*E1+2*STM-1(o)

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 36

CSHA/ CSHB/CSHCFunctional Modules


Functional Modules
The CSHA/CSHB/CSHC
comprises the system
control and
communication unit,
packet switching unit,
cross-connect unit, clock
unit, service interface
unit, and auxiliary
interface unit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 37

CSHA/ CSHB/CSHCSlot Allocation


CSHA/CSHB/CSHC boards are
inserted in slots 1 and 2 in the
IDU 910 chassis.
The CXPAR/CXPBR boards can be inserted only in slots 1 and 2 in the IDU 910 chassis.
The CXPAR/CXPBR boards cannot be inserted in the IDU 950 chassis.
Different logical boards are allocated for the CSHA, CSHB, and CSHC on the NMS.
Logical slots for the logical boards of the CSHA

Logical slots for the logical boards of the CSHB

Logical slots for the logical boards of the CSHC

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 38

CSHA/ CSHB/CSHCInterfaces
Button
Indicators

NE cascade interface

NM interface/NM
serial interface

CSHB

CSHC

External clock/time interface /The wayside E1 interface


Orderwire
interface

Synchronous/
Asynchronous
data interface

Auxiliary interfaces and


management interfaces

Auxiliary interfaces and


management interfaces

HUAWEI TECHNOLOGIES CO., LTD.

2*FE
interfaces

2*GE interfaces

Alarm
input/output
interface

E1 (1-16) interface

FE service
interfaces

FE service
interfaces

CSHA

GE service
interface

GE service
interfaces

Huawei Confidential

E1 1 16,17~32

STM-1 service
interfaces

Page 39

E1 1 16

CSHA/ CSHB/CSHCIndicators
Indicator

Color

State

Description

On (green)
STAT indicator

The board is working normally.

On (red)

The board hardware is faulty.


The board does not start to work, is not
created, or is not powered on.

Off

PROG indicator

On (green)

The upper layer software is being initialized or


the software is working normally.

On (red)

The memory self-check fails, the upper layer


software fails to be loaded, the logic file is lost,
or the upper layer software is lost.

On for 100 ms
(green) and off for
100 ms repeatedly

The information is being written to the flash or


the software is being loaded.

On for 300 ms
(green) and off for
300 ms repeatedly

When the board is being powered on or being


reset, the board software is in BIOS boot state.

On for 100 ms (red)


and off for 100 ms
repeatedly

The BOOTROM self-check fails or the loading


of the FPGA fails.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 40

CSHA/ CSHB/CSHCIndicators
Indicator

Color

SYNC indicator

State
On (green)
On (red)
On (green)

SRV indicator

The clock is operating normally.


The clock source is lost or is switched.
The services are working normally and no
alarms occur in the services.

On (red)

A critical or major alarm occurs in the


services.

On (yellow)

A minor or remote alarm occurs in the


services.

Off

HUAWEI TECHNOLOGIES CO., LTD.

Description

There is no power supplied to the system.

Huawei Confidential

Page 41

CSHA/ CSHB/CSHCIndicators
Indicator
LINK 1

ACT 1

LINK 2

ACT 2

LOS 1

LOS 2

Color

State

Description

On (green)

The port connection is normal.

Off

The port connection is interrupted.

On or blinking
(yellow)

The data is being transmitted or received.

Off

No data is being transmitted or received.

On (green)

The port connection is normal.

Off

The port connection is interrupted.

On or blinking
(yellow)

The data is being transmitted or received.

Off

No data is being transmitted or received.

On (red)

The first optical interface on the line reports the


R_LOS alarm.

Off

The first optical interface on the line does not


report the R_LOS alarm.

On (red)

The second optical interface on the line reports the


R_LOS alarm.

Off

The second optical interface on the line does not


report the R_LOS alarm.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 42

CSHA/ CSHB/CSHCButtons
Button

Description

CF RCV button

Used to restore the configuration data from the CF card.

RST button

Used to perform a warm reset on the equipment.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 43

CSHFunctions and Features

The CSH provides the 10 Gbit/s packet switching, full time division cross-connection,

system control and communication, and clock processing functions. In addition, the CSH
provides auxiliary interfaces and management interfaces.
Support Packet Switch, Provides the 10 Gbit/s packet switching capability.
Supports full time division cross-connections at the VC-12, VC-3, or VC-4 level,

which are equivalent to 32x32 VC-4s.


Provides one Ethernet NM interface/ NM serial interface.
Provides one NE cascade interface.
Provides one input and one output of the external clock. / Bypass E1 service

interface.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 44

CSHFunctional Block Diagram


The CSH comprises

the system control


and communication
unit, packet switching
unit, cross-connect
unit, clock unit, and
power supply unit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 45

CSHSlot Allocation
The CSH boards can be inserted in slots 7 and 8 and form a 1+1 protection group.

The CST boards can be inserted only in slots 7 and 8 in the IDU 950 chassis and form a

1+1 protection group.


The CST board cannot be installed in the IDU 910 chassis.
The logical slot of the CST on the NMS should be the same as the physical slot.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 46

CSH Front Panel


Indicators:
Board hardware status indicator (STAT) three colors
(red, green, and yellow)
Program running status indicator (PROG) two colors
(red and green)
Synchronization status indicator (SYNC) two colors (red
and green)
Service status indicators (SRV)-three colors (red, green,
and yellow)
Protection status indicators ACT Green indicator

NM
interface/NM
serial interface

External clock/time
interface /The
wayside E1 interface

The second time


interface

NE cascade
interface

CF RCV button: used to restore the configuration data from the CF card. After you press the CF RCV button
for 5 seconds, the equipment automatically restores the configuration data from the CF card.
RST button: used for warm reset on the board. When you press the RST button and then release it, a warm
reset is performed on the board.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 47

Contents

Boards
TDM system control, cross-connect, and timing board
Hybrid system control, cross-connect, and timing board
CSHA/CSHB/CSHC
CSH
IF board

IF1
IFU2
IFX2

Service interface board


Auxiliary and management interface board
Power supply board and fan board

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 48

IF1 Functions and Features

The IF1 is a medium-capacity SDH IF board . The IF1 board has the following functions
IF processing functions:

Maps SDH and PDH service signals into microwave frame signals.
Codes and decodes microwave frame signals.
Modulates and demodulates microwave frame signals
Modulates and demodulates ODU control signals
Combines and splits service signals, ODU control signals, and -48 V power
supplies.
Support ATPC Automatic Transmit Power Control function.
Protection Processing functions:
Support 1+1 HSB/FD/SD protection.
Support 1+1 FD/SD hitless switching.
Support N+1 protection.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 49

IF1 Functional Block Diagram


The IF1 board consists of

the combiner interface


module, IF processing
module, MODEM module,
SMODEM module,
MUX/DEMUX module, logic
and control module, power
module, and clock module.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 50

IF1 Slot Allocation


The IF1 receives and transmits one IF signal and provides the management channel to

the ODU and supplies the required -48 V power to the ODU.

IDU 910:
The IF1 board can be inserted in
slot 3 or slot 4.
IDU 950:
The IF1 board can be inserted in
any of slots 1 to 6.
To configure a 1+1 FD/SD
protection group, the IFE2
boards must be inserted in
paired slots.
The paired slots supported by
the IDU 950 are as follows: (slot
1, slot 2), (slot 3, slot 5), and
(slot 4, slot 6).
Slot allocation priority : Slots 3
and 5 > slots 4 and 6 > slots 1
and 2
HUAWEI TECHNOLOGIES CO., LTD.

IDU 910

IDU 950

Huawei Confidential

Page 51

IF1 Front Panel

IF interface (TNC)

HUAWEI TECHNOLOGIES CO., LTD.

ODU switch
When the switch is set to "O", it
indicates that the circuit is open.
When the switch is set to "I", it
indicates that the circuit is
closed.

Indicators:
Working status indicator (STAT) two colors (red and
green)
Status indicator (SRV) three colors (red, green, and
yellow)
Radio link status indicator (LINK) one color (green)
ODU status indicator (ODU) three colors (red, green, and
yellow)
Remote end status indicator (RMT) one color (yellow)
Protection status indicator (ACT) one color (green)

Huawei Confidential

Page 52

IF1Indicators
Indicator

Color

State
On (green)

STAT
indicator

On (red)
Off
On (green)

SRV
indicator

ACT
indicator

The board hardware is faulty.


The board does not start to work, is not created, or is not
powered on.
The services are working normally and no service alarm occurs.
A critical or major alarm occurs in the services.

On (yellow)

A minor or remote alarm occurs in the services.

On (green)

The ODU is working normally.

On (yellow)
On for 300 ms
(yellow) and off for
300 ms repeatedly

RMT
indicator

The board is working normally.

On (red)

On (red)
ODU
indicator

Description

The ODU has a critical or major alarm or has no power supply.


The ODU has a minor alarm.
The receive power of the ODU is lower than the required value.

On (yellow)

The microwave defect indication alarm is received from the


opposite end.

On (green)

The board is in the active state in the 1+1 protection system.


The board is already activated in the unprotected system.

Off

HUAWEI TECHNOLOGIES CO., LTD.

The board is in the standby state in the 1+1 protection system.


The board is not activated in the unprotected system.
Huawei Confidential

Page 53

IFU2 Functions and Features

The IFU2 is a general IF board, which can support the Hybrid microwave transmission and Packet

microwave transmission at the same time. In this version, the IFU2 supports only the Hybrid microwave
transmission.
Supports the Hybrid microwave frames, and supports the pure transmission of E1 or Ethernet

signals and the hybrid transmission of E1 and Ethernet signals.


Supports the adaptive modulation (AM) technology.
Provides a maximum of 56 MHz signal bandwidth and supports the highest modulation mode of

256QAM.
Maps service signals into microwave frame signals.
Codes and decodes microwave frame signals.
Modulates and demodulates microwave frame signals.
Modulates and demodulates ODU control signals.
Combines and splits service signals, ODU control signals, and -48 V power supplies.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 54

IFU2 Functional Block Diagram

The working principle and signal flow of


the Packet microwave IF signals are
similar to the working principle and signal
flow of the Hybrid microwave IF signals.
The only difference is with regard to the
frame structure. In the case of the Packet
microwave, the MUX/DEMUX unit only
multiplexes/demultiplexes the packet
services and does not transmit the TDM
services to the cross-connect unit or
receive the TDM services from the crossconnect unit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 55

IFU2 Slot Allocation


The IFU2 receives and transmits one Hybrid/Packet IF signal, provides the management

channel to the ODU, and supplies the required -48 V power to the ODU.
IDU 910:
The IFU2 board can be inserted
in slot 3 or slot 4.
IDU 910
IDU 950:
The IFU2 board can be inserted
in any of slots 1 to 6.
To configure a 1+1 FD/SD
protection group, the IFE2
boards must be inserted in
paired slots.
The paired slots supported by
the IDU 950 are as follows: (slot
1, slot 2), (slot 3, slot 5), and
(slot 4, slot 6).
Slot allocation priority : Slots 3
and 5 > slots 4 and 6 > slots 1
and 2
HUAWEI TECHNOLOGIES CO., LTD.

IDU 950

Huawei Confidential

Page 56

IFU2 Front Panel

IF interface (TNC)

HUAWEI TECHNOLOGIES CO., LTD.

ODU switch
When the switch is set to "O", it
indicates that the circuit is open.
When the switch is set to "I", it
indicates that the circuit is closed.

Indicators:
Working status indicator (STAT) two colors (red and
green)
Status indicator (SRV) three colors (red, green, and
yellow)
Radio link status indicator (LINK) one color (green)
ODU status indicator (ODU) three colors (red, green,
and yellow)
Remote end status indicator (RMT) one color (yellow)
Protection status indicator (ACT) one color (green)

Huawei Confidential

Page 57

IFX2 Functions and Features


The IFX2 is a general IF board, which can support the XPIC function of the Hybrid microwave and

SDH microwave. In this version, the IFX2 supports only the Hybrid microwave transmission.
Supports the XPIC function, provides the XPIC input and output interfaces, and supports the

manual configuration of the XPIC function.


Supports the Hybrid microwave frames and supports the pure transmission of E1 or

Ethernet signals and the hybrid transmission of E1 and Ethernet signals.


Supports the adaptive modulation (AM) technology.
Provides the maximum signal bandwidth of 56 MHz and supports the highest modulation

mode of 256QAM.
Maps service signals into microwave frame signals.
Codes and decodes microwave frame signals.
Modulates and demodulates microwave frame signals.
Modulates and demodulates ODU control signals.
Combines and splits service signals, ODU control signals, and -48 V power supplies.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 58

IFX2 Functional Block Diagram

The working principle and signal


flow of the Packet microwave IF
signals are similar to the working
principle and signal flow of the
Hybrid microwave IF signals. The
only difference is with regard to
the frame structure. In the case of
the Packet microwave, the
MUX/DEMUX unit only
multiplexes/demultiplexes the
packet services and does not
transmit the TDM services to the
cross-connect unit or receive the
TDM services from the crossconnect unit.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 59

IFX2 Slot Allocation


IDU 910:
The IFX2 board can be inserted
in slot 3 or slot 4.
IDU 910
IDU 950:
The IFX2 board can be inserted
in any of slots 1 to 6.
To configure a 1+1 FD/SD
protection group, the IFE2
boards must be inserted in
paired slots.
The paired slots supported by
the IDU 950 are as follows: (slot
1, slot 2), (slot 3, slot 5), and
(slot 4, slot 6).
Slot allocation priority : Slots 3
and 5 > slots 4 and 6 > slots 1
and 2

HUAWEI TECHNOLOGIES CO., LTD.

IDU 950

Huawei Confidential

Page 60

IFX2 Front Panel

ODU switch
When the switch is set
to "O", it indicates that the
circuit is open. When the
switch is set to "I", it
indicates that the circuit is
closed.

XPIC signal

interfaces

IF interface (TNC)

HUAWEI TECHNOLOGIES CO., LTD.

Indicators:
XPIC input signal indicator XPIC two colors (red
and green).
Working status indicator (STAT) two colors (red and green)
Status indicator (SRV) three colors (red, green, and
yellow)
Radio link status indicator (LINK) one color (green)
ODU status indicator (ODU) three colors (red, green, and
yellow)
Remote end status indicator (RMT) one color (yellow)
Protection status indicator (ACT) one color (green)

Huawei Confidential

Page 61

Precautions to Be Taken When Handling the


IF Boards

1
The ODU-PWR switch is equipped
with a lockup device. To turn on or
turn off the switch, you need to first
pull the switch lever outwards
slightly.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 62

Precautions to Be Taken When Handling


the IF Boards

2
When the ODU switch is set to I, do
not insert or remove the IF cable.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 63

IF Signal Parameters of the IFE2


Item

IF signal

ODU
management
signal

Performance

Transmit frequency (MHz)

350

Receive frequency (MHz)

140

Impedance (ohm)

50

Modulation mode

ASK

Transmit Frequency (MHz)

5.5

Receive frequency (MHz)

10

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 64

Contents

Boards
TDM system control, cross-connect, and timing board
Hybrid system control, cross-connect, and timing board
CSHA/CSHB/CSHC
CSH
IF board
IF1
IFU2
IFX2
Service interface board

EM6T/EM6F
SL1D
SP3S/SP3D

Auxiliary and management interface board

AUX

Power supply board and fan board

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 65

EM6T/EM6F Functions and Features

The EM6T/EM6F is an FE/GE interface board, which provides four FE electrical

interfaces and two GE interfaces. The EM6T has similar functions to the EM6F. The only
difference is as follows: the GE interfaces on the EM6T always function as electrical
interfaces whereas the GE interfaces on the EM6F use the SFP modules and therefore
can function as two optical or electrical interfaces. The GE electrical interfaces on the
EM6F and the EM6T are compatible with the FE electrical interfaces.
The EM6T/EM6F accesses, processes, and aggregates four FE signals and two GE

signals. In R2 version, the backplane service bus is 1G.


EM6T/EM6F support LAG function, support ERPS.
EM6T/EM6F support E-Line and E-Lan.
EM6T/EM6F supports synchronous Ethernet.
EM6T/EM6F support ETH-OAM function.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 66

EM6T/EM6F Functional Block


Diagram

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 67

EM6T/EM6FSlot Allocation

IDU 910:
The EM6T/EM6F board can
be inserted in slot 3 or slot 4.

IDU 910

IDU 950:
The EM6T/EM6F board can be
inserted in any of slots 1 to 6.
Slot allocation priority Slots 4
and 6 > slots 1 and 2 > slots 3
and 5

HUAWEI TECHNOLOGIES CO., LTD.

IDU 950

Huawei Confidential

Page 68

EM6T/EM6FFront Panel

GE
Indicators

interfacesRJ45

GE

interfaces-LC

FE interfaces-

RJ45

GE electrical interfaces on the front panel of the EM6T are compatible with the FE interfaces. The GE
interfaces on the front panel of the EM6F use pluggable SFP optical modules.

The FE electrical interfaces and GE electrical interfaces support the MDI and MDI-X adaptation modes.

The FE interfaces support 10M full duplex, 10M half duplex, 100M full duplex, 100M half duplex, and
auto-negotiation.

The GE electrical interfaces support 10M full duplex, 10M half duplex, 100M full duplex, 100M half
duplex, 1000M full duplex, and auto-negotiation.

The GE optical interfaces support 1000M full-duplex and auto-negotiation.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 69

SL1D Functions and Features

The SL1D is an SDH dual-port STM-1 board. The SL1D transmits and receives 2xSTM-1

optical signals.
Supports the automatic laser shutdown (ALS) function.
Supports SNCP and LMSP.
Supports the inloop and outloop over optical interfaces.
Supports the outloop on VC-4 paths.
Supports the warm reset and cold reset on the board.
Supports the query of the board manufacturing information.
Supports the in-service upgrade of the FPGA.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 70

SL1D Functional Block Diagram

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 71

SL1DSlot Allocation

IDU 910:
The SL1D board can be
inserted in slot 3 or slot 4.

IDU 910

IDU 950:
The SL1D board can be
inserted in any of slots 1 to 6.
Slot allocation priority Slots 4
and 6 > slots 1 and 2 > slots 3
and 5.

HUAWEI TECHNOLOGIES CO., LTD.

IDU 950

Huawei Confidential

Page 72

SL1DInterfaces

Indicators:
Working status indicator (STAT) two
colors (red and green)
Status indicator (SRV) three colors
(red, green, and yellow)
LOS1/LOS2: Whether the optical
interface have the R_LOS alarm.

STM-

1interface-LC

The type of the SFP optical module equipped on the SL1D, provides Ie-1 Multi-mode,

2km S-1.1 Single-mode, 15km L-1.1 Single-mode, 40km L-1.2


Single-mode, 80km

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 73

SP3S/SP3D Functions and Features

The SP3S is a 16xE1 75-ohm/120-ohm tributary board. The SP3D is a 32xE1 75-

ohm/120-ohm tributary board.


The E1 interface impedance of the SP3S/SP3D can be identified by the board feature

code of the bar code. In the bar code, the board feature code is the number next to the
board name.
Board Feature Code

Interface Impedance (Ohm)

120

75

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 74

SP3S/SP3D Functional Block Diagram

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 75

SP3S/SP3D Slot Allocation

IDU 910:
The SP3S/SP3D board can
be inserted in slot 3 or slot 4.

IDU 910

IDU 950:
The SP3S/SP3D board can be
inserted in any of slots 1 to 6.
Slot allocation priority Slots 4
and 6 > slots 1 and 2 > slots 3
and 5.

HUAWEI TECHNOLOGIES CO., LTD.

IDU 950

Huawei Confidential

Page 76

SP3S/SP3D Interfaces

Indicators:
Working status indicator (STAT) two
colors (red and green)
Status indicator (SRV) three colors
(red, green, and yellow)

E1 interface

NOTE:
In the case of the OptiX RTN 900, only the ports 1-16 and 22-37 of the SP3D interface are

used. Ports 1-16 correspond to E1 signals 1-16 and ports 22-37 correspond to E1 signals 1732.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 77

AUX Functions and Features

The AUX is the auxiliary and management interface board of the OptiX RTN 950 V1R2.

One NE can house only one AUX.


The AUX provides multiple auxiliary interfaces and management interfaces, including the

one orderwire interface, one synchronous data interface, one asynchronous data
interface, and one four-input/two-output external alarm interface.
Provides one orderwire interface.
Provides one 64 kbit/s synchronous transparent data interface.
Supports one 19.2 kbit/s asynchronous transparent data interface.
Supports the input of four channels of external alarms.
Supports the output of two channels of external alarms.
Supports hot swapping.
Supports the detection of the board power supply.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 78

AUX Functional Block Diagram

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 79

AUX Interfaces
Synchronous/

Orderwire

Alarm

Asynchronous
data interface

phone

output

Indicators:
Working status indicator (STAT) two
colors (red and green)
Status indicator (SRV) three colors
(red, green, and yellow)

Alarm input


The OptiX RTN equipment also supports the orderwire group call function. For example, when an OptiX RTN

equipment calls the number of 888, the orderwire group call number, all the OptiX RTN equipment orderwire phones
in the orderwire subnet ring until a phone is answered. Then, a point-to-point orderwire phone call is established.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 80

AUXSlot Allocation

IDU 950
The AUX board can be inserted in any of slots 1 to 6.
An NE can house only one AUX board.
The AUX board cannot be installed in the IDU 910 chassis.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 81

Contents

Boards
TDM system control, cross-connect, and timing board
Hybrid system control, cross-connect, and timing board
CSHA/CSHB/CSHC
CSH
IF board
IF1
IFU2
IFX2
Service interface board
Auxiliary and management interface board
Power supply board and fan board

PIU
FAN

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 82

Types of the PIU


The PIU board supports the functions and features such as power access, power

protection, lightning protection, and information reporting.


Board

Functional
Version

Description

Valid Slot

PIU

TNC1

Power access unit of the OptiX RTN


910

Slot 5 in the IDU 910

PIU

TND1

Power access unit of the OptiX RTN


950

Slot 9 and slot 10 in the IDU 950

IDU 910:
The PIU board whose functional
version is TNC1 is fixedly inserted
in slot 5. The two accessed power
supplies function as a hot backup
for each other.

IDU 950:
The PIU boards that have the
functional version of TND1 are
fixedly inserted in slot 9 and slot 10.
The two PIU boards function as a hot
backup for each other.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 83

Front Panel of the PIU


TNC1 PIU

BGND power
input interface

TND1 PIU

When the PWRA


and PWRB
indicators are on
and green, it
indicates that the
power is
accessed.

48 V power
input interface

One PIU board whose functional version is TNC1


accesses two 48 V DC (or -60 V DC) power
supplies for the equipment. The two power
supplies function as a hot backup for each other.

HUAWEI TECHNOLOGIES CO., LTD.

BGND power
input interface
48 V power
input interface

One PIU board whose functional version is TND1 accesses one 48 V


DC (or 60 V DC) power supply for the equipment. The PIU boards
that have the functional version of TND1 are fixedly inserted in slot 9
and slot 10. The two PIU boards function as a hot backup for each
other.

Huawei Confidential

Page 84

Types of the FAN


The FAN adjusts the fan rotating speed, and detects and reports the fan status.

Board

Functional
Version

Description

Valid Slot

FAN

TNC1

Fan of the OptiX RTN 910

Slot 5 in the IDU 910

FAN

TND1

Fan of the OptiX RTN 950

Slot 9 and slot 10 in the IDU 950

IDU 910:
The FAN board whose functional
version is TNC1 is fixedly inserted in
slot 6.
Accesses one +12 V power supply for
driving three fans, each of which
consumes 6 W power.
IDU 950:
The FAN board whose functional version
is TND1 is fixedly inserted in slot 11.
Accesses two +12 V power supplies for
driving six fans, each of which consumes
6 W power.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 85

Front Panel of the FAN


ESD wrist
strap jack

42CM

Indicator

Color

State
Green

FAN indicator

CRIT
indicator
MAJ indicator
MIN alarm

The fan is running normally.

Red

The fan is faulty.

Off

The fan is not powered on or is


not installed.

Red

The subrack has a critical


alarm.

Orange

The subrack has a major


alarm.

Yellow

The subrack has a minor


alarm.

HUAWEI TECHNOLOGIES CO., LTD.

86.2CM

Description

Huawei Confidential

Page 86

Summary

This course provides the following information:


Network position of the RTN 900 V100R002
System architecture and hardware structure of the RTN 900
V100R002
Boards on the OptiX RTN 900 V100R002
TDM system control, cross-connect, and timing board
:CSTA/CST

Hybrid system control, cross-connect, and timing board:

CSHA/CSHB/CSHC/CSH
IF board: IF1 IFU2 IFX2
Service interface board :
EM6T/EM6F SL1D SP3S/SP3D
Auxiliary and management interface board : AUX
Power supply board and fan board : PIU FAN

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 87

AppendixWeight and Power Consumption of Boards


Boards

Weight (kg)

Power consumption (W)

CSTA

1.079 kg

19W

CSHA

1.110 kg

19W

CSHB

1.158 kg

22W

CSHC

1.129 kg

20W

CST

0.720 kg

21W

CSH

0.740 kg

25W

IF1

0.720 kg

8W

IFU2

0.790 kg

22W

IFX2

0.796 kg

24W

EM6T/EM6F

0.370 kg / 0.382kg

12W

SL1D

0.296 kg

3W

SP3S

0.544 kg

5W

SP3D

0.644 kg

10W

AUX

0.270 kg

2.1W

PIU

0.120 kg

0.5W

FAN

0.200kg

2.3W (room temperature)


17W (high temperature)

HUAWEI TECHNOLOGIES CO., LTD.