Beruflich Dokumente
Kultur Dokumente
SM6 presentation
2
Joseph MARZOCCA - 17/10/02 - EN
3
Joseph MARZOCCA - 17/10/02 - EN
MV/MV
subtransmission
MV/LV
distribution
Building
Industry
Fluair/MCset
Fluair/MCset
SM61250A
SM6 1250A
SM6 630A
RM6
SM6 1250A
SM6 630A
SM6 630A
RM6
4
Joseph MARZOCCA - 17/10/02 - EN
5
Joseph MARZOCCA - 17/10/02 - EN
SM6 presentation
Market positioning
Booking
Range presentation
Technologie advantages
Competitors
Global Schneider advantages
Annex
6
Joseph MARZOCCA - 17/10/02 - EN
SM6 booking
The experience of a world leader
To ensure unsurpassed know-how
30 years of SF6 use
50 years of expertise in factory-built cubicles
Half a million SM6 units in operation
Quality service
Widespread sales network
7
Joseph MARZOCCA - 17/10/02 - EN
SM6 booking
Lot of plants in lot of countries planned
to supply at a very short delivery time
Schneider licencies
USA
Range presentation
Market positioning
Booking
Range presentation
Technologie advantages
Global Schneider advantages
Annex
9
Joseph MARZOCCA - 17/10/02 - EN
Range presentation
A adapted range for all your requirements
Extension possibilities
Easy of installation
Operating safe and easy
Compact design to save
space
Soft maintenance
Factory built assemblies
Protection and control
monitoring functions
10
Joseph MARZOCCA - 17/10/02 - EN
10
Range presentation
The experience of a world leader
More than 1200 000 SF6 switch units sold
SM6 24
SM6 36
11
11
Range presentation
Compartmented factory built cubicles
Switch cubicles
4
3
1. Switch
2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection
5
12
Joseph MARZOCCA - 17/10/02 - EN
12
Range presentation
Compartmented factory built cubicles
Switch fuse cubicles
4
3
1. Busbars
2. Switch
3. Operating mechanism
4. Low voltage
5. Connection
6. Fuse
6
5
13
Joseph MARZOCCA - 17/10/02 - EN
13
Range presentation
Compartmented factory built cubicles
SF6 circuit breaker cubicles
2
3
1. Switch
2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection and switchgear
14
Joseph MARZOCCA - 17/10/02 - EN
14
Range presentation
Compartmented factory built cubicles
Vacuum circuit breaker cubicles
2
1
3
5
1. Switch
2. Busbars
3. Operating mechanism
4. Low voltage
5. Connection and switchgear
3
15
Joseph MARZOCCA - 17/10/02 - EN
15
Range presentation
Compartmented factory built cubicles
Contactor cubicles
2
4
1
5
16
Joseph MARZOCCA - 17/10/02 - EN
16
Range presentation
SM6 product view
Safe and easy operation: total confidence
3
17
Joseph MARZOCCA - 17/10/02 - EN
17
Range presentation
1250 A range ...
To be present on MV / MV subtransmission market in
the countries where the metalclad concept is not really
specify in primary activity
Save size as 630 A cubicle
Developing the same functions with fix and
withdrawable offers
Range is limited to a disconnector and circuit breaker
cubicle
18
Joseph MARZOCCA - 17/10/02 - EN
18
Range presentation
36 kV range ...
To break into the Turkish market and to satisfy other
countries through France
Same function as 24 kV range limited at CB fixed
To move from traditional solution in the air
to a prefabricated Offer
Homogeneous range with 24 kV SM6 range
19
Joseph MARZOCCA - 17/10/02 - EN
19
Range presentation
Integrated protection chain
DM1-S : SF1 circuit breaker
DMV-S : Evolis circuit breaker
DM1-A : SFset circuit breaker
Reliable protection chain
Without low voltage
supply
20
Joseph MARZOCCA - 17/10/02 - EN
20
Range presentation
Internal Arc withstand
2 performances:
Regular 12,5kA.0,7s
Range 16kA.1s
21
Joseph MARZOCCA - 17/10/02 - EN
21
Range presentation
DMV A, D & S: vacuum CB cubicle ...
Width 625 mm
instead of
750 mm
Fixed circuit
breaker
Access to
cables
compartment
22
Joseph MARZOCCA - 17/10/02 - EN
22
Range presentation
Market positioning
Booking
Range presentation
Technology advantages
Competitors
Global Schneider advantages
Annex
23
Joseph MARZOCCA - 17/10/02 - EN
23
24
Joseph MARZOCCA - 17/10/02 - EN
24
Closed
Open
Earthed
25
Joseph MARZOCCA - 17/10/02 - EN
25
Closed
Open
Earthed
26
Joseph MARZOCCA - 17/10/02 - EN
26
in horizontal plane
Field distributors
Insulated busbars
No risk of error
27
Joseph MARZOCCA - 17/10/02 - EN
27
28
Joseph MARZOCCA - 17/10/02 - EN
28
29
Joseph MARZOCCA - 17/10/02 - EN
29
30
Joseph MARZOCCA - 17/10/02 - EN
30
31
Joseph MARZOCCA - 17/10/02 - EN
31
Cover
H = 1m60
Cabinet H = 2m05
Compartment H = 1m69
32
Joseph MARZOCCA - 17/10/02 - EN
32
Network protection :
VIP 300 : overcurrent
protections and earth
fault
VIP 200 and 201 : used
with SFset circuit breaker
10
t>
t>
t >>
t >>
0.1
0.01
I/Is
01.2
10
15
20
25
30
Is 1.2 Is
10 Is
I >>
Is 1.2 Is 10 Is
I >>
33
Joseph MARZOCCA - 17/10/02 - EN
33
Sepam 20 serie :
For common
applications
Sepam 80 serie :
For complete
applications
Sepam 40 serie :
For demanding
applications
34
Joseph MARZOCCA - 17/10/02 - EN
34
35
Joseph MARZOCCA - 17/10/02 - EN
35
36
Joseph MARZOCCA - 17/10/02 - EN
36
Range presentation
Market positioning
Booking
Range presentation
Technology advantages
Competitors
Global Schneider advantages
Annex
37
Joseph MARZOCCA - 17/10/02 - EN
37
Competition
Design cubicle
2 modular families
Totally
insulated--> RM6
Air Insulated System (AIS)-->SM6
2 CB families
With
38
Joseph MARZOCCA - 17/10/02 - EN
38
Competition
Mains advantages
3 positions switch in front of conventional family
Withdrawable CBs cubicle
SF6 or Vacuum CBs unit
Easy to manufacture for Panel Builders
Features
39
Joseph MARZOCCA - 17/10/02 - EN
39
Range presentation
Market positioning
Booking
Range presentation
Technology advantages
Competitors
Global Schneider advantages
Annex
40
Joseph MARZOCCA - 17/10/02 - EN
40
EDF/SEPIA
quality audit
Annual production
line sampling
Production sites
with ISO 9002
certification by AFAQ
ISO 14001 to meet
environmental rules
41
Joseph MARZOCCA - 17/10/02 - EN
41
Range presentation
Market positioning
Booking
Range presentation
Technology advantages
Competitors
Global Schneider advantages
Annex
42
Joseph MARZOCCA - 17/10/02 - EN
42
Annex
Connection to networks
Incoming or outgoing unit
IM
IMC
IMB
43
Joseph MARZOCCA - 17/10/02 - EN
43
Annex
Protection by fuse - switch combination
Fuses - switch unit
PM
Fuses - switch
combination unit
QM
44
Joseph MARZOCCA - 17/10/02 - EN
44
Annex
Protection by fuse - switch combination
Fuses - switch combination
unit
QMC
QMB
45
45
Annex
Fuses selection
46
Joseph MARZOCCA - 17/10/02 - EN
46
Annex
Protection by contactor
Contactor unit
CRM
CRM
47
Joseph MARZOCCA - 17/10/02 - EN
47
Annex
Protection by circuit breaker
Single - isolation circuit
breaker unit
DM1-A or DMV-A
DM1-D or DMV-D
(right only)
48
48
Annex
Protection by circuit breaker
Single-isolation circuit
breaker unit with
autonomous protection
DM1-S or DMV-S
DM2
49
49
Annex
Protection by circuit breaker
Withdrawable single isolation circuit breaker
unit cable outgoing
DM1 - W
DM1 - Z
50
50
Annex
Protection MV metering
Voltage transformers for
mains with earthed neutral
system
CM (375 mm)
51
Annex
Protection MV metering
Current and / or voltage
measurement unit, right or
left outgoing line
GBC - A
GBC - B
52
52
Annex
Functions required by private networks
Intermediate bus
unit
GIM
Extension unit
VM6 / SM6
GEM
Connection unit
right / left outgoing
line
GBM
53
Joseph MARZOCCA - 17/10/02 - EN
53
Annex
Functions required by private networks
Incoming cable connection unit
GAM 2
GAM
54
Joseph MARZOCCA - 17/10/02 - EN
54
Annex
Functions required by private networks
Disconnector unit
SM
MV / LV
transformer unit
for auxiliaries
TM
Earthing busbars
compartment
EMB
55
55
Annex
Functions required by private networks
Busbars power supply for main incoming line on
right or left and cables for standby line
NSM busbars
NSM cables
56
Joseph MARZOCCA - 17/10/02 - EN
56
Annex
Optimum performance
57
Joseph MARZOCCA - 17/10/02 - EN
57
Annex
General characteristics
58
Joseph MARZOCCA - 17/10/02 - EN
58
Annex
Endurance
59
Joseph MARZOCCA - 17/10/02 - EN
59
Annex
Operating mechanisms
60
Joseph MARZOCCA - 17/10/02 - EN
60
Annex
Easy installation
Simplified civil works
Symetric cable
connection
Identical cubicles heights
and floor - level depths
61
Joseph MARZOCCA - 17/10/02 - EN
61