Tellabs 8100

System Control Units

Objectives
> You will know Tellabs 8100 system control units
> SCU
> SCU-H

System Control Unit - SCU & SCU-H


> The purpose of SCU/SCU-H is to control and
>
>
>
>

monitor the functions of the subrack.


There has to be one control unit in every Tellabs
8100 node.
SCU/SCU-H can have optional modules.
SCU can be used in Tellabs 8150 basic nodes
and in the slaves of Tellabs 8170 cluster nodes.
SCU-H can be used in Tellabs 8150 basic nodes,
in the slaves of Tellabs 8170 cluster nodes and
in Tellabs 8160 accelerator nodes A111.

> SCU is discontinued.

Functions of SCU and SCU-H


>
>
>
>
>
>
>
>

Node inventory management


Backup of unit settings
Protection of the cross-connect system
Protection of control buses
Rack alarm (PMA, DMA, MEI) control
Event reporting to the Tellabs 8000 network manager
Channel test functions
Control channel support for HDLC-4CH or HDLC-16CH

Control Bus (VTP Bus)


> VTP = Virtual Token Protocol
> a collision-free media access method based on the token passing principle
implemented by the aid of timers

> The control bus is used for communication between


units in the same subrack.

> There are two control buses in the Tellabs


8150 basic node and the bus selection is
controlled by SCU/SCU-H.

> The control bus goes in slots 2-16 and


18-32.

> The bit rate is 2 Mbit/s.

Protection of Control Buses


Mother Board

VTP bus 1 2 Mbit/s


VTP bus 2 2 Mbit/s
VTP bus
selection line

SCP
UNIT 1

UNIT n

SXU

SXU

SCU/CCU

Node Inventory Management


PFU-A PFU-B GMH

GMH

GMH

VCM

CAE

VCM-10T

VCM

VCM SXU-A

SCU

PMA
DMA
MEI

BUS

SYNC

12

S
C

OUT

MP
1
2

IN

MP

BAT

BAT

POW

POW

MP

MP

MP

C
B
U
S

FUSE

BAT

FUSE

BAT

10

11

12

13

14

15

16

Slot
3
4
5
6
7
8
9
11
13
14
15
16
16

Unit
GMH
GMH
GMH
VCM-5T-A
VCM-10T-A
CAE
VCM-5T-A
VCM-5T-A
SXU-A
SCP
SCU

Backup of Unit Settings


> SCU/SCU-H takes backups of the interface parameters
of all the units that are in the subrack inventory.

> If a unit needs to be replaced, the control unit will copy


the settings of the old unit into the new one.

Rack Alarm Control


> Rack alarms, PMA, DMA, MEI are given if any unit
in the subrack has an active fault condition.

> The SCU/SCU-H collects these alarms from the


units.

> SCU/SCU-H controls the rack alarm LEDs located


in the power unit in slot one.

Interfaces & Optional Modules for SCU


> Async interface (9.6 kbit/s)
> Used to connect the DXX Server or Service Computer

> SCC-IF (64 kbit/s)


> Used to connect X.25 link to the DXX Server

> SCP Module


> 4 HDLC channels, more memory for backing up settings

> Alarm-IF
> Alarm input support

SCP - Extended Memory Support


> SCP adds additional extended backup memory to
the SCU unit

*) SCP is discontinued

Interfaces & Optional Modules for SCU-H


> Async interface (9.6 kbit/s)
> Used to connect the DXX Server or Service Computer

> Alarm-IF
> Alarm input support

> SCP-H Module


> 16 HDLC channels
> Ethernet interface
> Used to connect the DXX Server or Service Computer
> Provides 16 Ethernet control links
> Nominal capacity per one link is 64 kbit/s

SCU/SCP vs SCU-H/SCP-H

Summary