Beruflich Dokumente
Kultur Dokumente
Presentation
2 /31
3I + I0
10 I / 8 O
1 comm. port
3V + V0
Specific
protection
Substation
Transformer
Motor
S20
T20
M20
Generator
10 I / 8 O
1 comm. port
Logic equations
Sepam series 80
42 I / 23 O
2 comm. ports
Logic equations
Logipam
3I + I0
3V
B22
S40
67N
S41
67N
67
S42
G40
M41
T42
B80
67N
S81
T81
67N
67
S82
T82
81R
S84
87T
87M
3I + I0
2x3V + V0
3I + I0
4 Ides
3V + V0
T40
S80
3I + 2xI0
3V + V0
2x3I + 2xI0
3V + V0
Capacitor
B21
81R
Sepam series 40
Busbar
T87
M81
G82
M88
G88
M87
G87
B83
51C
C86
Sepam General.ppt
3 /31
Sepam 1000+
standard applications
For industrial and service
sector site networks
For public distribution
networks
For all voltage levels
Sepam General.ppt
4 /31
5 /31
Substation application
(S40/S41/S42 types)
Series 40
6 /31
Sepam General.ppt
7 /31
Transformer application
(T40/T42 types)
Series 40
Parallel transformers
Isolated or compensated
neutral networks
Protection functions:
50/51,50N/51N, 46,50BF
49RMS and 38/49T
67N/67NC, directional
earth fault
67, directional phase
overcurrent
I, U, P, E metering
Sepam General.ppt
8 /31
Sepam General.ppt
9 /31
Motor application
(M41 type)
Series 40
Isolated or compensated
neutral networks
All the M20 protection
functions, plus:
67N/67NC, directional
earth fault
32P, reverse power
27/59, 81L/81H,
Automatic load shedding
I, U, P, E metering
Sepam General.ppt
10 /31
Generator application
(G40 type)
Series 40
Protection functions:
50/51, 50N/51N,46,50BF
49RMS and 38/49T
27/59, 81L/81H,
Specific functions:
50V/51V, voltage
restraint overcurrent
32P, 32Q/40, directional
active and reactive
overpower
I, U, P, E measurements
Sepam General.ppt
11 /31
Series 20
Sepam General.ppt
12 /31
Sepam General.ppt
13 /31
Sepam 1000+
User Machine Interfaces
Logic inputs / outputs
Communication
Temperature acquisition
Analog output
Sepam General.ppt
14 /31
15 /31
To manage your
installation locally!
Advanced
User Machine Interface
The keypad and display are used to set the Sepam parameters and
protection functions and to display measurements and alarms.
The advanced UMI does not give access to the matrix (use SFT2841).
Sepam General.ppt
16 /31
Remote advanced
User Machine Interface
Module to be flushmounted
wherever
To improve
ergonomics
To facilitate
installation
N.B. The remote UMI may not be installed on the front panel
of Sepam.
Sepam General.ppt
17 /31
SFT2841 software
To make the most
of your Sepam !
The SFT2841 tool may be used to set parameters and protection functions and
customize Sepam. It provides the alarm history, disturbance records and
parameter down and uploading.
Sepam General.ppt
18 /31
Sepam 1000+
User Machine Interfaces
Sepam General.ppt
19 /31
Additional
Inputs / Outputs
4 logic outputs as a standard
feature
a choice of 2 additional
input/output modules:
MES108: 4 logic inputs/4
logic outputs
MES114: 10 logic inputs/4
logic outputs
To enhance the
monitoring/control
functions
This module is essential to be able to use certain functions.
Sepam General.ppt
20 /31
Sepam 1000+
User Machine Interfaces
Logic inputs / outputs
Communication
Temperature acquisition
Analog output
Sepam General.ppt
21 /31
Communication functions
Modbus/Jbus protocol
Measurement readouts
TS status readouts
Logic input status readouts
TC remote control orders
Remote settings
Control of the optional MSA114 analog output
Disturbance recording OPG readouts
Sepam General.ppt
22 /31
Communication interfaces
Modbus communication
protocol
ACE949-2: RS485 2-wire
communication interface
with distributed supply
2 wires for the RS485
signal
2 wires to supply the
ACE949-2
Auxiliary supply for the
ACE949-2 provided by the
ACE909-2 interface or the
ACE919 or a 12 or 24 V DC
external power supply
Sepam General.ppt
23 /31
Communication interfaces
Modbus communication
protocol
ACE959: RS485 4-wire
communication interface
with distributed supply
4 wires for the RS485
signal
2 wires to supply the
ACE959
Auxiliary supply for the
ACE959 provided by a 12 or
24 V DC external power
supply
Sepam General.ppt
24 /31
Sepam 1000+
User Machine Interfaces
Logic inputs / outputs
Communication
Temperature acquisition
Analog output
Sepam General.ppt
25 /31
Temperature
acquisition
Measurement
of 8 or 16
temperatures
By Pt100, Ni100 or
Ni120 temperature
sensors
For better motor,
generator and
transformer
protection!
Sepam General.ppt
26 /31
Sepam 1000+
User Machine Interfaces
Logic inputs / outputs
Communication
Temperature acquisition
Analog output
Sepam General.ppt
27 /31
Analog output
A choice of
formats (4-20mA,
0-10mA or 0-20mA)
Sepam General.ppt
28 /31
Sepam 1000+
a complete solution
Sepam General.ppt
29 /31
<100mm
Sepam General.ppt
30 /31
<100mm
Sepam General.ppt
31 /31