Sie sind auf Seite 1von 11

Fast Dormancy Activation

Prepared by: Hassan Rizwan

Agenda

1. Introduction
2. Trial Results
3. Summary

Introduction

3 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Introduction
Feature Description:
In the case of some applications, although the device may have completed its data transfer and not be expecting
further data exchange, the UE must wait for the network to move it from CELL_DCH or CELL_FACH to idle or
URA_PCH state. Because the UMTS networks cannot anticipate the data transfer characteristics of particular
applications, this can lead to excessive battery drain. The Fast Dormancy feature will allow operators to recover
control on how to manage UE devices and permitting to handle them in a more efficient way interms of network
resources and the signaling load of PS sessions.
Trial Objectives :
Increase the radio resources capacity.
Improvement also on the UE battery due to less DCH time and less RRC Connection requests Attempts.
Reduction of the signallng load by using more suitable transition states as Cell-PCH and URA-PCH.
Parameter Description: IsFastDormancyAllowed=True
T323=30
Trial Cluster: RNC N309

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Trial Results

5 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

SCRI(UE REQUESTED DATA SESSION END TO PCH)


SCRI with Cause UE Requested Data Session End to PCH now showing values(showing FD Enabled)

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

RRC/RAB REQUESTS
Further decrease in RRC Connection Requests(PS/HS) observed. .

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

DCH TO PCH STATE TRANSITIONS


Increase in State Transitions from DCH to URA_PCH observed.

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

PS/HS CALL DROP RATE


Further increase in HS_CDR observed

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Summary

10 | UA7.1.3 KPI Investigation Methodology | Feb. 2011

Alcatel-Lucent Internal
Proprietary Use pursuant to Company instruction.

Summary

Advantages:
Increase the radio resources capacity.
Improvement also on the UE battery due to less DCH time and less RRC Connection
requests Attempts.
Reduction of the signallng load by using more suitable transition states as Cell
PCH and URA-PCH
Disadvantages:
Further degradation observed in HS_CDR. Ticket opened with the Support Team for
this issue and awaiting their feedback.