Sie sind auf Seite 1von 14

Oilmax

CENTRIFUGAL OIL CLEANER


FOR Hydraulic Oil

Use Your Oil Maximum

Why Hydraulic Oil Cleaning


Is Required?
Hydraulic oil needs frequent replacement
due to Contamination generated within the
system like Wear Particle & Oxidation
Products.
There is also ingress of dust particles through
breathers provided on hydraulic tanks.
Contaminated oil causes Wear & Tear of high
precision hydraulic Components like hydraulic
Pumps, Cylinders, Oil seal, etc.
Clean hydraulic oil extends life of hydraulic
components, prevents Machine breakdown &
improves productivity.
2

Centrifuge Working
Principle
Centrifugal Oil Cleaner Operates on the

Reaction Turbine Principle.


Oil Enters the centrifuge Under Pressure

and flows to the rotor thru hollow shaft.


The Oil Pressure and flow is converted in

rotational energy as the oil escapes


through the jets, producing speed upto
6000 RPM.
The Resultant Centrifugal Force Removes

dirt from the Oil depositing it on the Inner


wall of rotor in a dense cake form.
Clean Oil Drains Back By Gravity to the oil

Tank.
3

Oilmax
Hydraulic Oil Cleaning System
TCS 500 PF
HD Fiber Filter

Centrifuge

Control Panel

Pressure
Gauge

Centrifuge
Cleaning Tray

Centrifuge

Fiber Filter

Magnetic
Filtration
Unit
Delivery
Pump
Suction

Suction Pump

Delivery

Specially developed
Inverted Rotor Design
Oilmax has specially developed inverted
rotor which has nozzles on the top of the
rotor.
In normal centrifugal oil cleaner, nozzles
are at the bottom of rotor hence when
the machine is Stopped the
Contamination collected in the rotor
flows out through Nozzles.
In the inverted rotor design the
Contamination remains in the
rotor till the rotor is taken out for the
cleaning
6

Inverted Rotor Design


Nozzles at top of the rotor

Normal Rotor Design


Nozzles at Bottom of the rotor

Installation

Hydraulic Power packs

Sludge Collected in Rotor & Fiber Filter


8

Installations

Wallem Ship Management- HK

Hydraulic Press

Observation Test

Patch Test

Before After
Before Cleaning

After Cleaning
10

Conclusion of Oil Test Report carried out by


Polytest Laboratories
Oil Sample A: Contaminated Oil
Oil Sample B: Taken after 60 minutes of centrifuging

of

contaminated oil.

Model
- SCC 075
Oil Grade
- ISO 46
Oil Quantity - 60 Ltr.
Particle
Count - in
Nos.
Particl
e Size

Reductio Reductio
n in
n in
Particles particles
count in count in
Nos.
%

Sample

Sample

Between
0.45 to 5

3,47,000

48,080

2,98,920

86.15%

Above 5

27,800

320

27,480

98.84%11

Oilmax Centrifugal Oil Cleaning System

12

Portable Unit TCS 500 PFM

13

Centrifuge Assembly Drawing SCC 075

14