MiCOM P13x
Feeder Management Relays
System-decoupling
Protective Signaling - Over/underfrequency
- Pilot wires - Over/undervoltage
- InterMiCOM - Directional power
... ...
Meas. Circuit monitoring
- MCB input Control
- Phase sequence monitoring - Control and monitoring
- Current unbalance monitor. of switchgear units
Operational support - Signals and commands
...
- Metering - Counter
- Limit value monitoring ...
...
6 > P13x Presentation EN < 6
MiCOM P13x
Feeder Management Relays
RTD
RTD
RTD
RTD
RTD
RTD
RTD
RTD
stator
RTD
RTD
rotor
bearing bearing
Models
P A N T X X X V X P A N T X X X X V
alt. X X Y alt. X X Y
A 6I 6I 4I A 6I 6I 4I
CH3 8O 8O CH3 8O 8O
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
determination module or
A InterMiCOM module with channel 3 or
1) Optional modules fitting according to Y RTD module with 9 RTDs (P139 only)
module location above X 6*I,6*O binary I/O-module for
P A N T X X X V X P A N T X X X X V
P139 CH1 alt.
CH2
4J 6I 6I 24I 4I
-/4V/5V 6O 6O 8O 6O
CH1 alt.
CH2
4J
-/4V/5V
6I
6O
6I
6O
24I
6O
4I
8O
Y Y
alt. alt. alt. alt.
9T 9T
alt. T Y alt. T Y
3J 3J
A 4I A 6V
4I
6V CH3
CH3
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
Standard:
P Processor module Options
T Transformer module: 4 CTs and 4 or 5 VTs
T Transformer module: 4 CTs or CT/VT module with NCIT (3J/6V)
A Communication module with channel 1 and 2
X 6*I,6*O binary I/O-module for
control of 3 switchgear units and IRIG-B or
Ethernet module with additional channel 2
V Power supply module with N Transient ground-fault direction
4 *I,8*O determination module or
A InterMiCOM module with channel 3 or
Y RTD module with 9 RTDs (P139 only)
X 6*I,6*O binary I/O module
1) Optional modules fitting according to
module location above for control of add. 3 switching devices
X 24*I binary input module or
DTOC
IDMT
100 10
t/s t/s
10
Long time inverse
100 100
t/s t/s
10
10
Long time
1 inverse
Short-circuit direction
determination
SCDD
A-B-C I V +45
C A-B
B-N IN V N-G
V N-G C-N IN V N-G
char.
angle A-B-N IN V N-G -90 ... +90
B-C-N IN V
N-G
IN C-A-N I V
N N-G
Forward A-B-C-N I V
N N-G
direction
Protective signaling
PSIG
Main features
P13x P13x
P13x P13x
SOTF
Application
L+ P13x
Logic
SOTF: Operating mode
Trip by I>
Trip by I>>
Trip by I>>>
DTOC: Starting I> Trip by gen. Start.
IDMT: Starting Iref,P> >1
&
DTOC: Starting I>>
&
SOTF:
DTOC: Starting I>>> >1
Trip signal
&
Main: General starting
&
MAIN: Manual close EXT
SOTF: Par. ARC runn. EXT SOTF: Man. close timer
&
ARC: Close request SOTF:
1 tManual
Close runn.
CBF
Logic
CBF:
Parallel trip EXT
CBF: tCBF
MAIN: &
General starting t 0
1 CBF: CB failure
MAIN:
Gen. Trip signal 1
CBF:
Starting trig. EXT
MAIN: & CBF: Trip signal
General starting
Auto-reclosing control
ARC
Main features
ASC
Main features
Automatically triggered by
Auto reclosure
Close request (Control function)
Manual CB close request
or triggering of ASC and subsequent manual close
command
Selectable reference voltage
Busbar-side or line-side
Measuring loop: VAB, VBC, VCA, VAG, VBG, VCG
Settable nominal voltage Vref,nom
Operating modes
Voltage-checked
Synchronism-checked
Voltage-/ synchronism-checked
Voltage check
Synchronism check
Motor protection
MP
Main features
t [s]
Start-up
1.000 Load Overload
logarithmic t 6Iref= 20 s
m =0
500
reziprocally
squared
3
2
1
TH ERM
Main features
Specific Proportionality
thermal capacity factor
w
(t) Thermal
conductance
Protected object
Temperature (t)
I2 k
a
a Coolant
Temperature a
Square of current
Model Equation
(t) a 2
Ultimate temperature I a a
k
t
t 0 0 1 e
0
a
Ultimate temperature rise
I
2
t a a,max
t 0 0 1 e trip
Iref max a,max
I t offset
o ffs e t
tr ip
100 %
0 %
a ,m a x m ax a
Unbalance protection
I2>
Main features
GFDSS
0 VN-G 0 VN-G
BS BS BS BS
GFDSS: GFDSS:
Sector angle BS GFDSS: Sector angle BS GFDSS:
IN,act> BS IN,act> BS
IN
270 90 270 90
GFDSS: GFDSS:
IN,act> LS GFDSS: IN,act> LS
IN Sector angle LS
GFDSS:
LS Sector angle LS LS LS
180 180
BS LS BS LS
IN
270 90 270 90
IN
BS LS BS LS
0 VN-G 0 VN-G
BS BS LS
GFDSS:
G(N)>/B(N)> BS
270 90 270 90
GFDSS:
G(N)>/B(N)> LS
LS
180 180
GFDSS: GFDSS:
G(N)>/B(N)> BS G(N)>/B(N)> LS
G(N): conductance
B(N): susceptance
60 > P13x Presentation EN < 60
MiCOM P13x
Over-/Undervoltage protection
V<>
Main features
Logic (1/3)
V<>:
Mode
Delta
V>
Star
+
V>>
+
+ V<
VA-N
V<<
VB-N
VC-N
Logic (2/3)
1 Vpos>
a2 Vpos>>
a Vpos<
Vpos<<
1
a Vneg>
a2 Vneg>>
V<>:
Evaluation
VN-G
calculated
measured
VA-N +
1
VB-N + VN-G >
3
VC-N + VN-G >>
VN-G
Logic (3/3)
1
V<>: V<
VB-N or VB-C t 0
1 V<>: tV< elapsed
Over-/Underfrequency protection
f< >
Main features
Over-/underfrequncy protection, four-stage
All four stages operate independently of each other
Operation modes:
Over-/underfrequency monitoring
Over-/underfrequency monitoring in conjunction with
differential frequency gradient monitoring (df/dt)
for system decoupling applications
Over-/underfrequency monitoring in conjunction with
average frequency gradient monitoring (f/t)
for load shedding applications
Settable operate delay
Sequence of all operate delays can be blocked
through appropriately configured binary signal inputs or
per selection matrix via a binary signal input or
per programmable logic (LOGIC)
f
fn o m t
Start
fx
Trip
tx
f
fn o m t
Start
fx
d fx/ d t
Trip
tx
Average ROCOF
f
fn o m t
Start
fx
fx
Trip
tx
P< >
Main features
MCMON
Main features
Logic
MCMON:
1 Meas. circ. V,I faulty
IA MCMON :
I diff>
IB Meas. circ. I faulty
En-
IC able
V< MCMON : Undervoltage
VA-N
MCMON :
VB-N 1 Meas. circ. V faulty
VC-N
MCMON :
Phase sequ. V faulty
MAIN:
MCMON :
General &
V> Meas. voltage o.k.
starting
LIMIT
Main features
> t>
0 1
M EA SI
Main Data
Signal processing
PC/
M CM O N L IM IT THERM
CO M M 1
ID C I D C , li n x x T
I n p u t s ig n a l A ID C ,n o m ID C ,n o m
x
x
x
ID C [m A ] D x
ID C / m A ID C / ID C ,n o m I D C , li n / I D C , n o m
L in e a r im a g e L in e a r iz a tio n S c a lin g
z e r o s u p p r e s s io n
M EA SO
Main Data
2 0 ,0
m A
1 0 ,0
0 ,0
0 ,0 0 0 m e a s u r a n d / r a n g e lim it v a lu e 1 ,0 0 0
Programmable logic
LOGIC
Fixed Logic:
Configuration: Configuration:
DTOC, IDMT, THERM, ...
OUTP
INP LED
LOC LOC
PC PC
COMM1 COMM1
COMM2 COMM2
COMM3 COMM3
Fixed Logic:
Configuration: Configuration:
DTOC, IDMT, THERM, ...
OUTP
INP LED
LOC LOC
PC PC
COMM1 COMM1
COMM2 COMM2
COMM3 Programmable Logic: COMM3
LOGIC