Hybrid Dryer

Functional Description
Hybrid Dryer
Combination of Heatless Desiccant dryer
and Refirgeration Dryer

Meant for removal of Moisture and Dust


particles in the compressed air to a degree
of 40 0 dew point and 5 microns.

Operating at 40 m3/min, 45 0 C inlet


temperature with operating pressure
7 kg/cm2
Schematic of Dryer System

R-1
20 M3/Min
HLD
40 M3/Min
R-2
20 M3/Min
LEGEND
R-1 : Refrigerant Dryer -1
R-2 : Refrigerant Dryer -2
HLD : Heat Less Dryer
: Dimensions to be indicated along with
the bid
: Dimensions will be finalised during order

: Bypass Pipe Line


: Flow Transmitter
Hybrid Dryer
Why Combination of Heatless and
Refirgeration Dryer ??
Heatless Desiccant dryer
Heatless desiccant Dryer can provide the
required dew point of 40 deg c.
The purge air used would be 13.4% of inlet
air and equals to 320 m3/hr. Which interms
of energy cost is very high.
Refrigeration dryer
In the refrigeration dryer there is no purge
loss
But the dewpoint achived is only 21 deg c
against the requirement of 40 deg c.
Hybrid dryer
Combination of both Refrigeration and
Healtess dryer
Increases the dewpoint to 40 deg and the
purge loss accounts to 0nly 0.2 % .
Refrigeration Dryer
Functional Items / componenets
2 Towers filled with mixed bed of activated alumina and
Molecular sieves
Heater
Blower
4/2 way Flow change over valves
Regeneration valve
Depressurise valve
Repressurise valve
Non return valve
Control panel
Pre filterwith cooler and
After filer
Refrigeration Dryer
Functional Items / componenets
Air/Air Heat Exchanger
Air / freon Evaporator
Pre cooler
Demister
Freon compressor
Condenser
Hot gas bypass valve
Expansion device
Pressuer switch
Controller
Refrigeration Dryer
Air / Air Heat Exchanger
Tube / Tube construction
Pre cools the compressed air before
entering in to the evaporator (A/F)
Re heats the outgoing air to the usable
level
Air / Freon Evaporator
Tube / Tube construction.
Cools the compressed air from the
Air/Air Heat exchanger to 3 deg c.
R 22 gas is used as Refrigerant gas.
Demister
Moisture separator connected in
between the Evoparator and Heat
Exchanger.
Separates the miosture condensed
due to the cooling effect.
Automatic drain valve at the bottom of
demister, drains the collection
Demister
Demister Drain Valve
Pre cooler
Water cooled after cooler, before the
Heat Exchanger to cool the
compressed air.
Refrigerant Compressor
Heart of the Dryer.
Compresses low pressure (50 PSI),
Low temperature gas in to High
pressure (240 PSI) and high
temperature gas.
Other Components
Water cool condenser
Pressure switch
Hot gasbypass valve
Expansion Device
Controller
Safety Interlock
When Discharge pressure goes above
280 PSI..
Pressure switch senses the high
pressuer and trips the compressor
High pressure Trip is indicated in the
front panel of the dryer
When discharge pressure goes below
220 PSI..
Hot gasbypass valve
Expansion Device
Controller
Safety Interlock
When Discharge pressure goes below
220 PSI..
Pressure switch senses the low
pressure and switches off the water
flow control valve
Automatically the waterflow control
valve is switched when the pressure
reaches 240 PSI
Maintenance
Sparekit replacement once in a year
for the Drain valve.
Demister element replacement once in
3 years
Refrigerant Gas replacement once in 5
years
Service the Water cool condenser with
Dil HCl, if required once in a year.
Trouble Shooting
Please refer the attachment
Desiccant Dryer
Functional Items / componenets
2 Towers filled with activated alumina Heater
3/2 way Flow change over valve
Regeneration valve
Repressurise valve
Non return valves
Control panel
Pre filter
After filer
Details
Refer the details in the Manual