Beruflich Dokumente
Kultur Dokumente
1500/2500/3500/7500
Hardware Description
www.huawei.com
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
Product Introduction
What is OSN
1500/2500/3500/7500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
Network Application
4010G 160 10G Long-
OptiX BWS OptiX BWS
Haul
1600G 1600G Back
Bone
iManager T2000 10G/2.5 10G/2.5
G
10G
G Core
OSN 3500 / OSN 7500/9500 OSN
7500/9500 3500/7500/9500
OSN
Convergen
OSN 1500 /2500
2500/3500 OSN 1500 /2500 ce
OSN 2500/Metro
OSN
1500 OSN1500 /Metro Access
/Metro
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
System Architecture
STM-64
STM-1 LU LU (OSN3500/7500)
Cross-connect Unit
STM-4/16 LU LU
High-order matrix
(VC-4)
Low-order matrix
(VC-12/VC-3)
PDH TU TU SAN/Video
Ethernet TU TU ATM
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Large Capacity and Multi-services
Access Large and multi-
services access
capacity
STM-1/4/16/64 STM-1/4/16/64
VC-4-4c/8c/ SDH unit SDH unit VC-4-4c/8c /
16c/64c 16c/64c
West
East
Cross-connect matrix
Large cross-
Multi-granularity
connect capacity
cross-connect
capacity
PDH Ethernet Other
Interface Interface Interface
unit unit unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Cabinet
ETSI 300/600 Cabinet
W(mm) D(mm) H(mm)
600 2000
600 2200
300 2600
2200 4 3 2 2
2600 4 4 2 2
H
W D
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Indicators
Statu
Indicator Color Description
s
Cabinet is powered
PowerCritical MajorMinor On
Power ON
Power distribution Boards Off Cabinet is OFF
Critical On Critical alarm
alarm Off No critical alarm
On Major alarm
Major alarm
Off No major alarm
On Minor alarm
Minor alarm
Off No minor alarm
Note:
Indicators do not flash
If alarm indicator is ON, alarm occurs on one or more sub-
connected
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
Power Distribution Unit
1 2 3 4 5 6
1 2 3
OUTPUT
4
A B 1 2 3
OUTPUT
4
ON ON
OFF OFF
INPUT
32A 32A 20A 20A 32A 32A 20A 20A
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
Power Consumption
DC power supply
Normal voltage: -48V or -60V
Range of input voltage: -48V20%(or -60V20 )
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
OptiX OSN 1500A Sub-rack
PIU
Core
Unit
Auxiliary Unit
FAN box
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
OptiX OSN 1500A Sub-rack
(Cont.)
SLOT 1 SLOT 11 SLOT 6 1.25G
SLOT 2 2.5G SLOT 7 1.25G
SLOT 20
FAN
SLOT 3 2.5G SLOT 8 1.25G
sp
SLOT 5 2.5G SLOT 10
l it
SLOT 1 SLOT 11 SLOT 6 1.25G
SLOT 2 1.25G SLOT 12 1.25G SLOT 7 1.25G
SLOT 20
FAN
SLOT 3 1.25G SLOT 13 1.25G SLOT 8 1.25G
SLOT 4 2.5G SLOT 9 1.25G
SLOT 5 2.5G SLOT 10
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
OptiX OSN 1500B Sub-rack
Core
Unit
Auxiliary Unit
FAN box
sp
SLOT 4 2.5G SLOT 9 622M
lit
SLOT 5 2.5G SLOT 10
SLOT 14
Slot Relation 7 15 SLOT 15
SLOT 18 PIU
(After split) SLOT 16
8 17 SLOT 19 PIU
SLOT 17
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
OptiX OSN 2500 Sub-rack
SEI (Auxiliary
Boards)
Service slot
area
Interface slot area
Core Unit
SAP (Auxiliary
Unit)
PIU
FAN Unit
Dimensions
447 (W) x 295 (D) x 472 (H)
(mm)
Weight (kg) 17 (without boards and fans)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
OptiX OSN 2500 Sub-rack
(Cont.)
Slot Relation 6 1, 2
S S S S S S S S S S
L L L L L L L L L L 7 3, 4
O O O O O O O O O O
SS S S T T T T T T T T T T SS S S
L L L L L L L L
5 6 7 8 9 10 11 12 13 14
OO O O OO OO 12 15, 16
sp
T T T T T T T T
1 2 3 4 6 6 2 2 2 2 2 2 1 S 1516 1718
13 17, 18
lit
2 2 . . . . . . . A
2 2 5 5 5 5 5 5 2 P
M M G G G G G G 5 S S S
L L L
G O O O S S S S S S S
Fiber routing panel
T T T L L L L L L L
19 20 21 O O O O O O O
SLOT 22 SLOT 23 SLOT 24 SLOT 25 S S S S 622 622 1.25
PIU FAN FAN PIU T T T T T T T S SSS
L L L L M M G L L L L
8 9 10 11 12 13 14
OOOO OOOO
Slot Relation 20 1 21 3 T T T T S
1 2 3 4 L
S S
L L 2 2 2 2 2 1
T T T T
S 15 161718
6 2 7 4
(After split) O O O . . . . . . A
T T T 5 5 5 5 5 25 P
15 1 5 6 7 G G G G G G
12 622 622 1.25
6 M M G
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
OptiX OSN 3500 Sub-rack
Interface slot area
Auxiliary
Unit
PIU
FAN boxes
SCC Unit
Cross-connect
Unit
Air filter
Dimensions 497 (W) x 295 (D) x 722
(mm) (H)
20 (without boards and
Weight (kg)
fans)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page19
OptiX OSN 3500 Sub-rack
(Cont.)
Slot Relation S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T
19, 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
2 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
20
P P A
21, I I U
3 U U X
22
FAN FAN FAN
23,
4
24 S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S S S S S S S S
L L L L L L L L
25, O
T
O
T
O
T
O
T
O
T
O
T
O
T
O
T
O
T
O
T
O O O O O O O O
T T T T T T T T
5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
26 XCS XCS S S
C C
C C
29,
13
30
Fiber Routing
31,
14
32
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
OptiX OSN 3500 Sub-rack
(Cont.)
Configure 1
Access capacity
FAN FAN FAN
:35G
S S S S S S S S S S S S S S S S S S
622 M x 8 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
2.5 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
10 G x 2 6 6 6 6 6 2 2 10 G G 10 2 2 6 6 6
2 2 2 2 2 . . G X X G . . 2 2 2 S S
2 2 2 2 2 5 5 C C 5 5 2 2 2 C C
M M M M M G G S S G G M M M C C
Fiber Routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
OptiX OSN 3500 Sub-rack
(Cont.)
Configure 2
Access capacity
FAN FAN FAN
:58.75G
S S S S S S S S S S S S S S S S S S
1.25 G x 7 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
2.5 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
10 Gx4 1 1 1 1 2 2 10 10 E E 10 10 2 2 1 1 1.
/ / 25
. . . . . . G G U U G G . . . . G S
2 2 2 2 5 5 X X 5 5 2 2 / C
5 5 5 5 G G C C G G 5 5 S C
G G G G S S G G C
C
Fiber Routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
OptiX OSN 3500 Sub-rack
(Cont.)
Configure 3
Access capacity
FAN FAN FAN
:155G
S S S S S S S S S S S S S S S S S S
5 Gx 7 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
10 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
20 G x 4 5 5 5 5 10 10 20 20 S S 20 20 10 10 5 5 5G S
G G G G G G G G X X G G G G G G S/ C
C C C C
S S C
Fiber Routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
OptiX OSN 7500 Sub-rack
SCC
Interface slot area
Service slot
area
Auxiliary Unit
FAN
boxes
Cross-connect
Unit
Service slot
area
Air
filter 496.4 (W) x 295 (D) x
Dimensions
(mm) 756.7 (H)
30 (without boards and
Weight (kg)
fans)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
OptiX OSN 7500 Sub-rack
(Cont.) S S S S LS LSS S S S S S S SLOT S S S S S
L OL O
Slot Relation L
O
L
O
L
O O TO
L
TO
L
O
L
O
L
O
L
O
L
O
L
O
L 32
O
L
O
L
O
L
O
L
O
L
O
PIU(A)
T T T T 1T 1TT T T T T T T T T T T T
1 2 2 2 72 822 2 2 2 2 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 4 5 6 7 8
SLOT
S S 33
19,
2
SCC(A)
SCC(B)
PIU(B)
C C
EOW
AUX
20
21, Fiber routing Fiber routing Fiber routing
3 FAN FAN FAN
22
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
35, O O O O O O O O O O O O O O O O O O
17 T T T T T T T T
8
T T T T T T T T T T
36 1 2 3 4 5 6 7 9 1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
37,
18
XCS(A)
XCS(B)
38
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
OptiX OSN 7500 Sub-rack
(Cont.)
Configure 1 S S S S S
O
L LS S
O
S S S S S S SLOT S S S S S
L L L L TL TL L L L L L L L 32 L L L L L
PIU(A)
O O O O 1O 1O O O O O O O O O O O O O
Access capacity T T T T 7T 8T T T T T T T T T T T T T
19 20 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38
:200G SE SS S 10 10 10 10 10 10 33 A
SLOT
PIU(B)
O C C G G G G G G U
C C
W C C X
5 Gx4
Fiber routing Fiber routing Fiber routing
10 G x 18 FAN FAN FAN
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
5 5 10 10 10 10 10 10 G G 10 10 10 10 10 10 5 5
G G G G G G G G / / G G G G G G G G
E E
X X
C C
S S
Fiber routing Fiber routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
OptiX OSN 7500 Sub-rack
(Cont.)
Configure 2 S S S S S
O
L LS S
O
S S S S S S SLOT S S S S S
L L L L TL TL L L L L L L L 32 L L L L L
PIU(A)
O O O O 1O 1O O O O O O O O O O O O O
Access capacity T T T T 7T 8T T T T T T T T T T T T T
19 20 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38
:280G SE SS S 10 10 10 10 20 20 33 A
SLOT
PIU(B)
O C C G G G G G G U
C C
10 G x 16 W C C X
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
10 10 10 10 10 10 20 20 S S 20 20 10 10 10 10 10 10
G G G G G G G G / / G G G G G G G G
U U
X X
C C
S S
Fiber routing Fiber routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
Questions
Please list the slot access capacity of the equipment.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
Contents
3. Boards
3.1 SDH Unit
3.2 PDH Unit
3.3 Ethernet Unit
3.4 ATM Unit
3.5 MST Unit
3.6 WDM Unit
3.7 Cross-connect and System Control Unit
3.8 Auxiliary Unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
SDH Unit
Boards appearance type
Processing
Interface
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
SDH Unit (Cont.)
S L Q 16
4:STM-4
O: 8*STM-N signals 1:STM-1
T: 12*STM-N signals
H: 16*STM-N signals
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
SDH Unit (Cont.)
Board Description
Connect
Board Full name Module available
or type
1 x STM-64 processing with Fixed wavelength output, I-64.2, S-
SF64 64.2b, L-64.2b, Le-64.2, Ls-64.2, V-
optical interface board (FEC) 64.2b (with BA, PA, and DCU)
Fixed wavelength output, I-64.2, S-
1 x STM-64 processing with
SL64 64.2b, L-64.2b, Le-64.2, Ls-64.2,V-
optical interface board
64.2b
1 x STM-16 processing with Fixed wavelength output
SF16
optical interface board (FEC) Ve-16.2c, Ve-16.2d, and Ve-16.2f LC
4 x STM-16 processing with
SLQ16 I-16, S-16.1, L-16.1, L-16.2
optical interface board
Fixed wavelength output, I-16, S-
1 x STM-16 processing with 16.1, L-16.1, L-16.2, L-16.2Je, V-
SL16 (A)
optical interface board 16.2Je (with BA), and U-16.2Je (with
BA and PA)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
SDH Unit (Cont.)
SL64 SF64 SF16 SL16 SL Q16 SL16A
SFP Module
STAT S TAT
STAT STAT
4 indicators
STAT ACT STAT
ACT ACT ACT ACT P ROG ACT
PROG PROG PROG PROG S RV PROG
SRV SRV SRV SRV SRV
CLASS1
L ASER
PRODUCT
LC Connector
O U T 1 IN 1
O U T 2IN 2
OUT OUT OUT OUT OUT
O U T 3IN 3
Electrostatic IN IN IN IN IN
Discharge
O U T 4IN 4
CLASS 1
SL 6 4 SF64 SF16 SL16 SLQ4 SL16A LASER
PRODUCT
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
SDH Unit (Cont.)
Slot available
Slot available
Board OSN OSN 3500 OSN 7500
OSN OSN
Name 1500
1500B 2500 40G 80G 200G 240G 360G
A
4 ~ 8, 11 ~ 16,
SF64
26 ~ 31
8, 11 7, 8, 11, 12 3 ~ 8,
1 ~ 8, 11
11 ~
SL64 ~ 18, 26
16, 26
~ 31
~ 31
SF16 3 ~ 8,
7, 8, 1 ~ 8,
6 ~ 8, 11 ~
SL16( 12, 13 11~13 11 ~ 5 ~ 8, 11 ~ 14 11 ~ 18,
11 ~ 13 16, 26
A) 13 26 ~ 31
~ 31
1 ~ 8,
1 ~ 8, 11 ~ 18,
SLQ16 11 ~
26 ~ 31
16
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
SDH Unit (Cont.)
Board Description
Connector
Board Full name Module available
type
O U T1 IN 1 O U T2 IN 2 O U T3 IN 3 O U T4 IN 4 O U T5 IN 5 O U T6 IN 6 O U T7 IN 7 O U T8IN 8
OUT OUT
O U T 1IN 1
O U T 1IN 1
O U T 1 IN 1
IN IN
O U T 2IN 2
O U T 2IN 2
O U T 2IN 2
O U T 3IN 3
O U T 3IN 3
O U T 4IN 4
O U T 4IN 4
0 1 0O U T 1IN
1 1 1O U T 1IN
CLAS S1
2 12
LAS ER
CLASS 1 PRODUCT
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
SDH Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name 360
1500A 1500B 2500 40G 80G 200G 240G
G
SLQ4 6 ~ 8, 5 ~ 8, 11 ~ 14
11 ~
SLD4
13
SL4 5 ~ 8, 1 ~ 8, 11 ~
12, 13 11~13
SLT1 11 ~ 13 1 ~ 8, 1 ~ 8, 11 ~ 17 18, 26 ~ 31
SLO1 11 ~
SLQ1 16
SL1
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
SDH Unit (Cont.)
Boards Description
Connector Signal
Board Full name processing with
type
2 x STM-1 processing with electrical electrical
SEP1 SMB interface board
interface board
Connector
Board Full name
(Interface) type
8 x optical signal access Interface
OU08 LC/SC (I-1 and S-1.1)
board
8 x electrical signal access
EU08 SMB
board
Board Full
4 name signal access
x electrical
EU04
Tributary Switch Board for 4
SMB TPS
board
TSB4
signals
Tributary Switch Board for 8
TSB8
signals
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
SDH Unit (Cont.)
SEP1
No need for interface board
SMB interfaces on the front panel are used
Can be inserted in all line slots
SEP
Need interface board: EU08, OU08, EU04
SMB interfaces on the front panel are inhibited
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
SC Connector
SFP Module
PRODUCT
CLASS 1
LASER
Page41
TSB8
TSB8
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
OU08
OU08
OU08
SDH Unit (Cont.)
EU04
EU04
EU08
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
AOUT AIN BOUT BIN
SEP1
SEP1
PROG
STAT
SRV
ACT
SLH1
SLH1
PROG
STAT
SRV
ACT
ct
M
B
C
S
o
n
n
o
e
r
SDH Unit (Cont.)
Slot available
Slot available
Board OSN OSN 3500 OSN 7500
OSN OSN
Name 1500
1500B 2500 40G 80G 200G 240G 360G
A
5 ~ 8,
SEP1 12,13 11~13 11 ~ 1 ~ 6, 13 ~ 16 1 ~ 3, 17, 18
13
2 ~ 5,
SLH1 13 ~
16
2, 3, 17, 18
6 ~ 7,
SEP 12, 13 12 ~ 2 ~ 5, 13 ~ 16
13
OU08 19,
21,
23, 19 ~
1 ~ 4, 25, 26, 29 19 ~ 22, 35 ~
EU08 29, ~ 36
14, 16 15 ~ 38
18 31,
33, 35
19, 21, 23, 25, 29, 31,
EU04
Copyright 2006 Huawei Technologies Co., Ltd.33, 35 reserved.
All rights Page42
TSB4
SDH Unit (Cont.)
Boards Description
Connecto
Board Full name Module available
r type
2 x STM-4 processing
R1SLD4 with optical interface
I-4, S-4.1, L-4.1, L-4.2, Ve-
board
4.2
STM-4 processing with
R1SL4
optical interface board
LC
4 x STM-1 processing
R1SLQ1 with optical interface
I-1, S-1.1, L-1.1, L-1.2, Ve-
board
1.2
STM-1 processing with
R1SL1
optical interface board
Signal processing with optical interface board
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
SDH Unit (Cont.)
SFP Module
STAT
STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV
O U T 1IN 1 O U T 2IN 2
O U T IN
R1SLD4 R1SL4 R1SLQ1 R1SL1
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
SDH Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name 80 200
1500A 1500B 2500 40G 240G 360G
G G
R1SLD 1 ~ 3,
7, 21
4 11 ~ 13
R1SL4 2, 3, 6
~ 9, 12, 1 ~ 3, 6
R1SLQ 13 5 ~ 7,19
~ 9, 11 ~
1 ~ 21
13
R1SL1
R1- boards are used in the small slots in OptiX OSN 1500 or when slots
are segmented in OptiX OSN 1500/2500.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
SDH Unit (Cont.)
Indicator
Indicato
Status Color Description
r
On, green Board works normally.
STAT
Board On, red Board hardware fails.
Status
Off Board is powered off.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
SDH Unit (Cont.)
Indicator
Indicat Colo
Status Description
or r
Upload of board software to FLASH or
On, green the FPGA upload is normal, or the
board software initialization is normal.
On for 100ms and off
for Board software is being uploaded to
100ms alternatively, FLASH or FGPA.
PROG green
Board On for 300ms and off
Softwar for Board software is initializing, and is in
e 300ms alternatively, BIOS boot stage.
green
Board software in FLASH or the FPGA
On, red configuration is lost, resulting in upload
and initialization failure.
Off No power supply.
unit
Send to Cross-connect
16
X
VC
STM- 4
16
TR
AU -P
H and ssing
O ce
pro
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
SDH Unit (Cont.)
Features of SL16
Fixed wavelength output
Automatic laser shutdown (ALS) function
Swappable optical module (SFP)
Support VC-4-4c, VC-4-8C and VC-4-16c
services
Inloop and outloop function
Setting and querying of the REG working
1 Last six digits of BOM
2 Internal number
mode 3 Board version
4 Board name
5 Board characteristic number
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
SDH Unit (Cont.)
Optical port parameters of SL16
Optical interface V-
S- L- U-16.2Je
I-16 L-16.1 L-16.2 16.2Je
type (Board 16.1 16.2Je (BA+PA)
(01) (03) (04) (BA)
characteristic #) (02) (02) (04)
(03)
Wavelength (nm) 1310 1310 1310 1550 1550 1550 1550.12
0 2 15 40 80 80
Distance (km) 140 170
2 15 40 80 100 140
Launched power -
10~- -5~0 -2~3 -2~3 5~7 14 17
(dBm) 3
Receiver sensitivity
-18 -18 -27 -28 -28 -28 -34
(dBm)
Receiver overload
-3 0 -9 -9 -9 -9 -10
(dBm)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50
SDH Unit (Cont.)
Common alarms of SDH
unit
Alarm Colo Alarm
level r name Alarm reason
Critical R_LOS Receiver can not receive STM-N signal normally.
MS_AIS Critical alarm e.g. R_LOS happens.
Critical alarm e.g. R_LOS happens.
AU_AIS Wrong service configuration
Major Faulty SDH board
POWER_
ABNORMA Power module of the line board fails.
L
Opposite station receives the R_LOS, R_LOF or
MS_AIS signal
MS_RDI
Faulty receiver at the opposite node or
transmitter at the local node
Minor Opposite node receives such alarms as AU_AIS
and AU_LOP.
HP_RDI
Faulty receiver at the opposite node or
transmitter at the local node
LOOP_ALM Software inloop or outloop is being performed.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page51
SDH Unit (Cont.)
Common performance events of SDH unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page52
PDH Unit
Board
Description Interface board
Name
SPQ4 Processes 4 x E4/STM-1 MU04
PD3 Processes 6 x E3/T3 D34S
PL3 Processes 3 x E3/T3 C34S
PL3A Processes 3 x E3/T3
PQM Processes 63 x E1/T1
D75S, D12S, D12B
PQ1 Processes 63 x E1
PD1 Processes 32 x E1/T1 L75S,L12S,D75S,D12S,D12B
PL1 Processes 16 x E1/T1
PD1 and PL1 are used in the small slot in OptiX OSN 1500/2500.
L75S/L12S can be only used in OptiX OSN 1500A.
PD1 cooperates with L75S/L12S in OptiX OSN 1500A, and cooperates with
D75S/D12S in OptiX OSN 2500 or OptiX OSN 1500B.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page53
PDH Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
SPQ4
6, 7,
PD3 12, 13 2 ~ 5, 13 ~ 16 2, 3, 17, 18
12, 13
PL3
5 ~ 8, 1 ~ 8,
1 ~ 8, 11 ~ 18, 26
PL3A 12, 13 11~13 11 ~ 11 ~ 1 ~ 8, 11 ~ 17
~ 31
13 16
MU04
1, 3, 19, 21, 23, 25, 29, 31, 19, 21, 35, 37
D34S 14, 16
15, 17 33, 35
C34S
PL3A is a processing board with cables led out from the front panel. .
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page54
PDH Unit (Cont.)
SPQ4/MU04 SPQ4
STAT
M U 04
ACT
PROG
SRV
SMB connector
Indicators
O U T 1 IN 1 O U T 2 IN 2
O U T 3 IN 3 O U T 4 IN 4
SPQ4 MU04
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page55
PDH Unit (Cont.)
PL3A D34S C34S
PD3 PL3
STAT
STAT STAT ACT
ACT ACT PROG
PROG PROG SRV
SRV SRV
SMB connector
Indicators
O U T 1 I N 1 O U T 2I N 2 O U T 3I N 3
O U T 1I N 1 O U T 2I N 2 O U T 3 I N 3
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page56
PDH Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
PQM 5 ~ 7,
11 ~
12, 13 1 ~ 5, 13 ~ 16 1, 2, 3, 17, 18
13
PQ1
D75S
14 ~ 1 ~ 4, 19 ~ 22 ,35 ~
D12S
17 15 ~ 18
19 ~ 26, 29 ~ 36
38
D12B
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page57
PDH Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
1 ~ 3, 6
5 ~ 7,
PD1 2, 12 ~ 8, 11
19 ~ 21
~ 13
L75S
6~7
L12S
PL1 is a processing board with cables let out from the front panel.
PD1/PL1 can be used in the small slot or used when slots are segmented in OptiX
OSN 1500/2500.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page58
PDH Unit (Cont.)
Indicators DB44
P Q1 D 75 S D1 2 S D 12 B
PQM
STAT STAT
ACT ACT
PROG PROG
SRV SRV
18
18
18
2mmHM
916
916
916
PD1 P L1 L7 5 S L 12S
STAT STAT
1724
1724
1724
ACT ACT
PROG PROG
SRV SRV
2532
2532
2532
1-16
1-16
1-16
PQM D7 5 S D 1 2S D 12 B
PQ 1
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page59
PDH Unit (Cont.)
Functions of PQ1 to SC
C
d
Sen
Collect Alarm
and
performance
unit
Send to Cross-connect
1 X VC4
63
X
E1
E1
s ing
roces
p
P TR
T U-
H and
LP O
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page60
PDH Unit (Cont.)
Features of PQ1
Interface Type: 75 or 120
Support Inloop and outloop functions
Support Warm and Cold reset
Support TPS function
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page61
PDH Unit (Cont.)
Common alarms of PDH unit
Alarm Colo
Alarm name Alarm reason
level r
ALM_SUBCARD_AB The interface board and the processing
N board are mismatched
T_ALOS No E1 service is accessed
Major
Critical alarm e.g. R_LOS happens
TU_AIS Wrong service configuration
Faulty PDH board
Opposite node receives such alarms as
LP_RDI
Minor TU_AIS and TU_LOP
LP_REI LPBBE happens on the opposite node
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page62
PDH Unit (Cont.)
Common performance of PDH unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page63
Ethernet Unit
E G T 2
T: Transparent transmission
G: Gigabit Ethernet (GE)
F: Fast Ethernet (FE) S: L2 switching
M: Multiple (GE+FE) R: RPR (Resilient Packet Ring )
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page64
Ethernet Unit
Boards Description
Connecto
Board Full name Interface type
r
4 x GE with L2 switching
EGS4 processing with interface 1000BASE-SX/LX/ZX LC
board
2 x GE with L2 switching
EGS2 processing with interface 1000BASE-SX/LX/ZX LC
board
2 x GE transparent
EGT2 transmission processing 1000BASE-SX/LX/ZX LC
with interface board
4 GE + 16 x FE with L2 1000BASE-SX/LX/ZX,
EMS4 switching processing with 100Base-FX (From interface RJ-45, LC
interface board board)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page65
Ethernet Unit (Cont.)
EGS4 EG S 2 EGT2 EM S4
STAT STAT
STAT STAT
ACT ACT
ACT ACT
PROG PROG
PROG PROG
SRV SRV SRV
SRV
LINK1 LINK1
ACT1 ACT1
LINK2 LINK2
ACT2 ACT2
CLASS 1 CLASS 1
LASER LASER
PRODUCT PRODUCT
CLASS 1
LASER
CLASS 1
LASER CLASS 1
PRODUCT PRODUCT
LASER
PRODUCT
O U T 1IN 1
O U T 1 IN 1
O U T 1IN 1
O U T 1IN 1
O U T 2IN 2
O U T 2 IN 2
O U T 2IN 2
O U T 2IN 2
O U T 3IN 3
O U T 3 IN 3
Indicato Statu
Color Description
r s
O U T 4IN 4
O U T 4 IN 4
On Link is established
LINK ACT LINK ACT
LINK Link is not
Off
established
EGS4 EGS2 EGT2 EMS4 Flashin
Data exchanged
g
ACT
No data being
Off
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page66 exchanged
Ethernet Unit (Cont.)
Board Full name EGR2 EMR0
STAT STAT
ACT
PROG ACT
SRV PROG
CLASS 1
EMR0
PRODUCT
PRODUCT
board
O U T 1IN 1
O U T 1IN 1
Function
O U T 2IN 2
EVPL/EVPLAN Service
FE1
QoS
FE2
Resilient Packet Ring Function
Weighted fair algorithm and three service FE3
levels
GE PORT FE4
Auto discovery of topology SFP Module
Wrap and steering protection
FE PORT EGR2 EMR0
RJ 45 connector
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page67
Ethernet Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
EGS4
1 ~ 8, 11 ~ 18,
EGS2 11 ~ 13 1 ~ 8, 11 ~ 16
12, 13 26 ~ 31
EGT2 5 ~ 8, 11
~ 13
1 ~ 4,
(11)12,
EMS4 1 ~ 6, 13 ~ 16 15 1 ~ 3, 17 ~ 18
13
~16
6, 7, 12, 1 ~ 8, 11 ~ 18,
EGR2 1 ~ 8, 11 ~ 16
(11)12, 13 26 ~ 31
12, 13
13 5 ~ 8, 11
EMR0 1 ~ 6, 13 ~ 16 1, 2, 3, 17, 18
~ 13
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page68
Ethernet Unit (Cont.)
Boards Description
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page69
Ethernet Unit (Cont.)
EFS4 EFS0 EFT 8
STAT STAT
ACT STAT
ACT ACT
PROG PROG PROG
SRV SRV SRV
RJ 45 connector
FE1
FE2
FE1
FE3
FE4
FE2 EFT4
FE5 STAT
ACT
PROG
FE6 SRV
FE3 FE7
FE1
FE8
FE2
FE4
FE3
FE4
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page70
Ethernet Unit (Cont.)
ETS8 EFF8 ETF8
1
FE PORT 2
3
4
RJ 45 5
6
7
Connector 8
LINK ACT
Board Interface
FE1
FE4
FE2
Name Board
FE3
FE5
EFT8 ETF8,EFF8
FE4
FE6
EFS0 ETF8,EFF8,ETS8
FE7
FE5
EMS4
FE8
ETF8,EFF8
FE6
EMR0
CLASS 1
LASER
FE7
PRODUCT
FE8
E T S8 EFF 8 ETF8
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page71
Ethernet Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
OSN OSN OSN
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
11 ~ 5 ~ 8, 1 ~ 8, 11 ~ 18,
EFS4 12, 13 1 ~ 8, 11 ~ 16 (17)
13 11 ~ 13 26 ~ 31
6, 7, 12,
EFS0 2 ~ 5, 13 ~ 16 2, 3, 17, 18
13
12 ~
7, 12, 13
13 1 ~ 8, 11 ~ 18,
EFT8 (5 ~ 8, 11 1 ~ 6, 13 ~ 16
26 ~ 31
~ 13)
1 ~ 3,
2, 3, 6,
6~ 5 ~ 7, 19
EFT4 9, 12,
9, 12, ~ 21
13
13
ETF8
14 ~ 1, 3, 15, 19, 21, 23, 25, 29, 31,
ETS8 19, 21, 35, 37
16 17 33, 35
EFF8
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page72
Ethernet Unit (Cont.)
Function of EFS4
C
d to SC
Sen
Collect Alarm
and
performance
unit
Send to Cross-connect
FE GFP
NVC12/VC3
VC-12- 8 X VC4
4 Xv(x63), VC-
X 3-Xv(x12)
FE
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page73
Ethernet Unit (Cont.)
Features of EFS4
Supports bandwidth auto-sensing
Supports MPLS
Supports LCAS
Supports Port based flow control
Supports receiving and transmitting Ethernet testing frame
Supports inloop at Ethernet port and inloop and outloop at
VC3 level
Supports port level Ethernet performance monitoring
Supports EPL/EPLAN/EVPL/EVPLAN services and QoS
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page74
Ethernet Unit (Cont.)
Common alarms of Ethernet unit
Alarm
Color Alarm name Alarm reason
level
HARD_BAD Faulty board hardware
Critical
ETH_LOS Interrupted Ethernet link
TU_AIS_VC3 Interrupted contiguous VC3-xc
Major
PROTOCOL_MM Mismatched encapsulation protocol
TU_AIS_VC3 happens in the opposite
LP_RDI_VC3
node
Minor
LCAS_BAND_
VC-Trunk bandwidth decreases
DECREASED
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page75
Ethernet Unit (Cont.)
Common performance events of Ethernet unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page76
ATM Unit
Boards Description
Connect
Board Full name Interface type
or type
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page77
ATM Unit (Cont.)
ADL4 ADQ1 IDL4 IDQ 1
STAT STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV
O U T 1IN 1
O U TIN
O U T 1IN 1
O U T 1IN 1
S
1 1
CLASS 1 F
O U T 2IN 2
O U T IN
LASER
PRODUCT
P
2 2
C
O U T 3IN 3
O U T I3N 3
O
N
N
O U T 4IN 4
O U T I4N 4
E
C
T
O
ADL4 ADQ1 IDL4 ID Q1
R
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page78
ATM Unit (Cont.)
Slot available
Slot available
Board OSN 3500 OSN 7500
Name OSN OSN OSN
1500A 1500B 2500 40G 80G 200G 240G 360G
ADL4 6 ~ 8,
1 ~ 8, 11 ~
11 ~
17
ADQ1 13
(11), 7, 8, 1 ~ 8, 11 ~ 18,
12, 13
12, 13 11~13 26 ~ 31
IDL4 1 ~ 8,
1 ~ 8,11 ~
11 ~
17
IDQ1 16
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page79
ATM Unit (Cont.)
Function of ADQ1
C
d to SC
Sen
Collect Alarm
and
performance
unit
Send to Cross-connect
Mapp
ATM er
8
VC-12, VC-4, X
VC-4-Xv VC
4
4
X
ATM
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page80
ATM Unit (Cont.)
Features of ADQ1
Supports CBR, rt-VBR, nrt-VBR and UBR
Supports QoS
ATM switching capability: 1.25 Gbit/s
Max. uplink bandwidth: 8 VC-4, or 12 VC-3 + 4 VC-4
E3 traffic can be received from PDH board
Supports ATM multicast connection
Supports VP-Ring and VC-Ring
Uni-directional/bidirectional 1+1 and 1:1 board protection
Supports inloop and outloop
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page81
ATM Unit (Cont.)
Common alarms of ATM unit
Alar
Colo Alarm
m Alarm reason
r name
level
More critical alarms e.g. R_LOS happens.
VP_AIS
Critic The faulty ATM board
al More critical alarms e.g. R_LOS happens.
VC_AIS
The faulty ATM board
The VP_AIS is reported on the opposite node ATM
VP_RDI
board
Major The VC_AIS is reported on the opposite node ATM
VC_RDI
board
LCD The cell heads are lost
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page82
ATM Unit (Cont.)
Common performance of ATM
unit
Performance name Performance meaning
VC3BBE VC3 block of background error
VC3ES VC3 errored second
VC3FEBBE VC3 far end block of background error
VC3FEES VC3 far end errored second
ATM_INGCELL Number of input cells in ATM link
ATM_EGCELL Number of output cells in ATM link
ATM_CORRECTED_HCSER Number of corrected cells with HCS error at ATM
R interface
ATM_UNCORRECTED_HCS Number of uncorrected cells with HCS error at ATM
ERR interface
ATM_RECV_CELL Number of cells ATM interface received
ATM_RECV_IDLECELL Number of idle cells ATM interface received
ATM_TRAN_CELL Number of cells ATM interface transmitted
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page83
MST Unit
Board description
4 x multi-service transparent
MST4 transmission processing with
interface board
Slot available
Slot available
Board
Name OSN OSN OSN OSN OSN
1500A 1500B 2500 3500 7500
1 ~ 8, 11
5 ~ 8, 11 1 ~ 8, 11
MST4 12, 13 11 ~ 13 ~ 18, 26
~ 13 ~ 16 (17)
~ 31
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page84
MST Unit
Service Types
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page85
MST Unit (Cont.)
MST4
STAT
Features of MST unit
ACT
PROG
SRV
P
Distance extension function for ports 1
C
O U T 3IN 3
O and 2
N
N
SFP Modules
O U T 4IN 4
E SDH
C Services Client side
side
T
O FC100 3000km 40km
M ST 4 R FC200 1500km 20km
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page86
MST Unit (Cont.)
Function
to SCC
d
Sen
Collect Alarm
and
performance
unit
Send to Cross-connect
GFP-T
SAN 16
Multi-Services
VC-4- X
4c/8c/16c VC
4
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page87
WDM Unit
LWX
STM-4 STM-4
STM-16 STM-16
MR2
Board
Description
Name
Arbitrary bit rate wavelength conversion processing with
LWX
interface board
MR2A
MR2B 2-channel optical add/drop multiplexing board
MR2C
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page88
WDM Unit
Slot available
Slot available
Board OSN OSN 3500 OSN 7500
OSN OSN
Name 1500
1500A 2500 40G 80G 200G 240G 360G
B
2, 3, 1 ~ 3,
6~ 6 ~ 9, 5 ~ 7,
MR2B
9, 12, 11 ~ 19 ~ 21
13 13
14 ~ 1 ~ 4,
MR2C 19 ~ 26, 29 ~ 36 19 ~ 22, 35 ~ 38
17 15 ~ 18
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page89
WDM Unit (Cont.)
LWX
LWX
STAT
Typ ACT
PROG
Interface Description
SRV
e CLASS 1
LASER
PRODUCT
TXRX
OUT1/OUT Sends signals to the optical add/drop multiplexing
2 board
LC
O U T 1IN 1
TX Sends service signal to client-side equipment
O U T 2IN 2
RX
equipment
LWX
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page90
WDM Unit (Cont.)
SDH SDH
PDH PDH
FE FE
ATM ATM
FICON FICON
FC OCh FC
LWX LWX
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page91
WDM Unit (Cont.)
Board type Protection Description
Protection Working
OTU OTU
OTU Coupler
Client-side Client-side
equipment equipment
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page92
WDM Unit (Cont.)
MR2A/MR2C
Function
M R 2A
O U TA O 1
Interfa Typ
A O 2M I
Description
ce e
A01 Access two channels of service signal
M OD O 2
A02 added locally.
D01
D O 1IN
Drop two channels of service signal locally.
D02
Receive two channels of multiplexed
IN LC
signal.
M R2A
OUT Send two channels of multiplexed signal.
Concatenation interface, through which
MO/MI multiple MR2A/MR2C boards can be
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
concatenated. Page93
WDM Unit (Cont.)
Drop1 Drop2 Drop1 Drop2 Drop1 Drop2
Out MI Out MI Out MI
MR2A/ MR2A/ MR2A/
MR2C MR2C MR2C
In MO In MO In MO
Add1 Add2 Add1 Add2 Add1 Add2
In Out
Drop1 Add2
MR2A/
LWX LWX
MR2C
Add1 Drop2
MI MO
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page94
WDM Unit (Cont.)
Common alarms of WDM unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page95
WDM Unit (Cont.)
Common performance of WDM
unit
Performance
Performance meaning
name
LSOOPMAX Maximum value of laser output optical power
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page96
Core Unit -OSN 1500/2500
The CXL1/CXL4/CXL16 is the core unit used in OptiX OSN 1500/2500.
Cross-connect Unit Timing Unit SCC Unit Line Unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page97
Cross-Connect Unit
SDH unit PDH unit Data unit C
to SC
d
Sen
Collect Alarm
High-order cross-connect
matrix
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page98
Cross-Connect Unit
OSN1500/2500
C XL 16 CX L4 C XL 1
STAT STAT
ACTX
STAT
ACTX ACTX
ACTC ACTC
PROG ACTC
PROG
SRVX SRVX PROG
SRVL SRVL SRVX
SYNC SYNC SRVL
ALMC ALMC SYNC
ALMC
CLASS 1 CLASS 1
CLASS 1
Indicat Colo
LASER LASER
PRODUCT LASER
PRODUCT
PRODUCT
Description
or r
OUTIN
O U TIN
OUT IN
Logical unit
GXCL (5G)
C XL 16 C X L4 CX L 1 EXCL (20G)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page99
Cross-connect Unit
OSN3500/7500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page100
Cross-Connect Unit OSN3500
OSN 3500
For
Cross-connect Max High-order Low-order
Extension
and timing access cross-connect cross-connect
sub-rack HO
board capacity capacity capacity
XC capacity
GXCS 35G 40G 5G
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page101
Cross-Connect and Timing Unit
OSN3500
GXCSA EXCSA UXCSA UXCSB XCE SXCSA SXCSB
STAT STAT STAT STAT STAT STAT
ACT STAT
ACT ACT ACT ACT ACT ACT
PROG PROG PROG
PROG PROG PROG SRV PROG
SRV SRV SRV SRV SRV SRV
SYNC SYNC SYNC SYNC SYNC SYNC SYNC
EXB EXB
EXB
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page102
Cross-connect Unit OSN3500
DB26
UXCSB XCE
STAT
ACT
STAT
ACT
Connector:
To connect the
PROG PROG
SRV SRV
SYNC SYNC
EXA EXA
EXB EXB
EXB EXB
EXA EXA
EXB EXB
UXCSB XCE
XCE
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page103
Cross-Connect Unit OSN7500
OSN 7500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page104
Cross-Connect and Timing Unit
OSN7500
GXCSA EXCSA SXCSA UXCSA
STAT STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV
SYNC SYNC SYNC SYNC
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page105
Cross-Connect Unit
Cross-
Standby
PDH unit connect PDH unit
Active
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page106
Timing Unit OSN1500/2500
Indicato
Color Description
r
Clock works in Normal mode
SYNC Clock works in hold-over or free-run
mode
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page107
Timing Unit OSN3500/7500
Indicat Colo
Description
or r
ON Board is active/OFF Board is
ACT
standby
Clock works in Normal mode
SYNC Clock works in hold-over or free-run
mode
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page108
Timing Unit
Features
Process traced clock signal from Line, Tributary and external
clock
Process 2 x Input/ 2 x Output 2Mbits/2Mhz external clock
signals
Support Normal (Trace), Hold-over and Free-run clock status
working modes
Process SSM byte to realize clock protection switching
Non-synchronization status message (SSM) mode
Standard SSM mode
Extended SSM mode
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page109
Cross-Connection & Timing
Unit
Common alarms of Cross-Connect and
Timing
Alarm
unit
Colo
Alarm name Alarm reason
level r
Chip of the cross-connect board is damaged
BUS_ERR
Damaged backplane bus
APS_INDI MSP switching happens
Major
TEMP_OVER Ambient temperature is too high.
Ejector lever on the front panel is rotated to the open
W_OFFLINE
position.
Physical interface signal of the external clock source is
EXT_SYNC_LOS
lost.
Minor
CLOCK_ENTER_N Clock working mode changes from locked into holdover
O_TRACE_MODE or free-run.
Multiplex section protection switching fails.
APS_FAIL
MS node information is lost or set incorrectly
Warning
SWITCH_DISABLE Board switching is disabled
OTH_BD_STATUS Another board pulled out or plugged in
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page110
System Control & Communication
Unit
SDH unit
Command
s
PDH unit
Collect Alarm and
performance NMS
Other unit
Other NE
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page111
System Control & Communication
Unit OSN1500/2500
C XL 1
Active SCC unit ACTC ( )
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC
Standby SCC unit ACTC ( )
CLASS 1
LASER
PRODUCT
Reset
To cut buzzer temporarily, press ALMC for 1 second
board ( )
RESET
ALM CUT
To cut buzzer permanently, press ALMC for 3 seconds
( )
Alarm cut
switch To re-enable buzzer, press ALMC for 1 second
(short and
long ( )
press) Logical unit
SCC
CXL1 GSCC (with ASON)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page112
System Control & Communication
Unit OSN3500/7500 (Cont.)
Indicat
SCC GSCC Color Description
STAT
STAT
ACT
or
ACT
PROG PROG
SRV
PWRA
PWRB
Reset SRV
PWRA
PWRB The 48 V power supply A is normal.
PWRC PWRC
ALMC ALMC
RESET
The 3.3 V protection power is normal.
PWRC
The 3.3 V protection power is lost.
Alarm cut ALM CUT
Currently in permanent alarm cut-off status.
ALMC
To warm reset board, press RESET
Give audible warning upon critical alarm.
To cut buzzer temporarily, press ALMC for 1 second ( )
SCC GSCC
To re-enable buzzer, press ALMC for 1 second ( )
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page113
System Control & Communication
Unit (Cont.)
Functions
Service configuration, grooming and monitoring
Collects alarm and performance events
Supports NE ID setting by software
1+1 hot backup
Extended ECC
Controls cabinet indicators and fans
3 Housekeeping alarm inputs and 1 alarm outputs
Supports ASON intelligent function
OSN 3500: Inserted in slot 18 (Active) and/or Slot 17 (Standby)
OSN 7500: Inserted in slot 24 (Active) and/or Slot 25 (Standby)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page114
System Control & Communication
Unit (Cont.)
Extended ECC function
NMS
Ring A Ring B
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page115
System Control & Communication
Unit (Cont.)
Four databases on the SCC
Issued data MDB
Automatically saves the current
data in dynamic RAM.
If power fails, the data in MDB
will be lost.
MDB
DRDB
Automatically saves the Fail NE in installing
verify status
successfully verified data.
If power fails, the data in
Success
DRDB will be lost.
Boards in
FDB0, FDB1
DRDB running status
Manually or periodically
saves the data. Enduringly Save manually or
saves data and does not periodically every 30 mins
need battery.
FDB0
FDB1
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page116
System Control & Communication
Unit (Cont.)
Common alarms of SCC unit
Alarm Colo
Alarm name Alarm reason
level r
Critical NESTATE_INSTALL NE is in the installing state.
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page117
Auxiliary Unit
Board Description
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page118
Auxiliary Unit AUX&AMU (OSN
1500)
ETH: T2000 Interface
AUX
AUX
ETH COM CLK ALM OAM/F&f The AUX board used in
OptiX OSN 1500 is
inserted in slot 10.
OM: Commissioning Interface
LK : 120 ohms external clock input/output interface
LM: House-keeping alarm input/output interface
AM/F&f: NM and management serial interface
PHONE: Orderwire Interface
AMU
PROG
STAT
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page119
Auxiliary Unit -SAP&SEI (OSN
2500)
ALMO1/2: Alarm output SAP is the system auxiliary
Q1SAP
ALMI1/2: 8 x Environment alarm input processing board. It is STAT
PROG
ALMI1 ALMI2 S1 S2 S3 S4 V1 V2
ETH
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page120
Auxiliary Unit -AUX (OSN 3500)
The AUX board used in OptiX OSN 3500 provides system
auxiliary interfaces. It is inserted in slot 37.
NIAUX
CLKO1 CLKO2 CLK1 REV F&f F1 PHONE V1 V2 OAM S1 S2 S3 S4
CLK1/2: 120 Ext clock input/output 1/2 ALMP1/2: Cabinet indicator output
ETH: T2000 ALM01/2: Alarm output
COM: Commissioning Phone: Orderwire
EXT: Extended sub-rack V1/2: NNI Audio/Signaling
REV: - OAM: X.25 OAM
F&f: LCT
F1: Co-directional data 64 Kbit/s
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page121
Auxiliary Unit -AUX (OSN 7500)
The AUX board is the system auxiliary interface board used
in OptiX OSN 7500, which is seated in slot 34 of the sub-rack .
CLKI3 CLKO3
AUX
AUX
CLK4 REV F&f F1 LAMP1 LAMP2 ALMO1 ALMO2 ALMI1 ALMI2 ALMI3 ALMI4
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page122
Auxiliary Unit -PIU
R1PIUA is applicable to the
P IUA
P IUA
POWER
POW ER
CLK IN
R 1 P IU
R 1 P IU
PWR
Switch
NEG(-) RTN(+) CLK OUT
PS1 PIU
Used in OSN 2500
Inserted in slot 22 and 25 PS2
Interfac Description
e
PWS 50 W power output
interface, supplying power
N I PI U
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page125
Auxiliary Unit -EOW (OSN
1500)
The EOW board is the orderwire board used in OptiX OSN 1500,
which is inserted in slot 9 of the sub-rack.
The AMU/EOW or some SDH/PDH unit can be inserted in slot 9 of
the sub-rack. Insert different boards due to different demands.
EOW
EOW
PROG
STAT
PHONE S1 S2 S3 S4
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page126
Auxiliary Unit -UPM (OSN1500)
(Cont.) 4
BAT
! CAUTION
BAT- DO NOT INVERT POLARITY
BAT+
48V+
48V-
LOAD1 LOAD2
5 6
RS232
1 2 3
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page127
Auxiliary Unit -EOW (OSN
7500)
The EOW board used in OptiX
Board
status OSN 7500 is inserted in slot 23.
CLKI1: 75 Ext clock input 1
CLKO1: 75 Ext clock output 1
CLKI1 CLKO1
EOW
EOW
STAT
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page128
Amplifier Unit -BA2&BPA&COA
Connect
Board Description
or
BA2 Booster Amplifier Board LC
BPA Pre-amplifier Board LC
COA Case-based Optical Amplifier LC
Slot available
Board OSN OSN OSN OSN OSN
1500A 1500B 2500 3500 7500
COA External
BA2 1 ~ 8, 11
5 ~ 8, 11 1 ~ 8, 11
12, 13 11 ~ 13 ~ 18, 26
BPA ~ 13 ~ 16 (17)
~ 31
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page129
Auxiliary Unit BA2
Tx BA Rx
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page130
Auxiliary Unit BA2 (Cont.)
BA2
STA T
ACT
PR OG
SR V
1/ 2 BA
modules
O U T1 IN 1
LC connector
Specifications
O U T2IN 2
Output 1 Output 2
IN1/2 (dBm)
(dbm) (dbm)
CLASS 1
LASER +13 ~ +15 -
PRODUCT
+15 ~ +17 -
6 ~ +3 +13 ~ +15 +13 ~ +15
+15 ~ +17 +15 ~ +17
BA2
+13 ~ +15 +15 ~ +17
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page131
Auxiliary Unit BA2 (Cont.)
Function
2 channel power amplification
Used on TX side
Fixed output optical power
Used for 1530 ~ 1565 nm signals
Reports laser performance parameter
ALS function
Automatic control of laser temperature and optical
power of the EDFA module
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page132
Auxiliary Unit BPA
Tx PA Rx
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page133
Auxiliary Unit BPA (Cont.)
BPA
STAT
ACT
PROG
SRV
Port 1:
BA module
LC connector
Specifications
B OU T B IN
CLASS 1
LASER
PRODUCT
BPA
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page134
Auxiliary Unit BPA (Cont.)
Function
1-channel power amplification
1-channel pre-amplification
Fixed output optical power
Improving the receiver sensitivity to 38 dBm
BA used for 1530 ~ 1565 nm signals
PA used for 1550.12 nm signals
ALS function
Reports performance parameter
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page135
Auxiliary Unit COA
8 9 10
1 2 3 4 5 6 7 11
2. Running 3. Alarm
1. ID DIP switch 4. RS232-1
indicator indicator
8. IN input optical
5. RS232-2 6. MONITOR-1 7. MONITOR-2
port
9. OUT
Copyright output
2006 optical
Huawei Technologies Co., Ltd. All rights reserved.
10. Power switch Page136
11. 48 V power interface
Auxiliary Unit COA (Cont.)
External installation
Types
61COA
Only one EDFA module
Can work as BA (+14 dBm or +17dBm), PA (with the receiver
sensitivity of 38 dBm ) or LA
62COA
Raman amplifier with good noise performance
used in the RX (with the receiver sensitivity of 39 dBm)
Ultra long hop transmission for a single span (>170 km )
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page137
Amplifier Unit
Common alarms of Amplifier unit
Alarm
Color Alarm name Alarm reason
level
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page138
Amplifier Unit
Common performance of Amplifier unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page139
Auxiliary Unit -DCU
DC U
O U TI1N 1
O U T 2IN 2
Slot available
1 ~ 8, 1~8,
DCU 11 ~ 11~18,
16(17) 26~31
DC U
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page140
Auxiliary Unit DCU (Cont.)
Compensates
Compensates
60km or 80km
60km or 80km
Tx BA PA DCU
DCU Rx
Insertion loss 7 dB
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page141
Auxiliary Unit -FAN
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page142
Auxiliary Unit -FAN (Cont.)
Function
Support hot swapping
Intelligent speed adjustment
Indicator Color Description
Fan operates normally.
Fan, fan power board or FANA is
STAT
abnormal.
Fan is turned off due to low temperature.
Faulty fan
Major FAN_FAIL
Fan is power off
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page143
Questions
Please list different boards in OptiX OSN
1500/2500/3500/7500.
SDH Boards
PDH Boards
Ethernet Boards
ATM Boards
MST Boards
WDM Boards
Cross-connect and
System Control
Boards
Auxiliary Unit
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page144
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page145
Contents
4. Common network elements
4.1 Terminal multiplexer (TM)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page146
Terminal multiplexer
TM
3 x E3s
Tributary unit Line
PIU Slot 1PIU Slot 11L75S Slot 6
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page148
Terminal multiplexer (Cont.)
TM configuration
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page149
Terminal multiplexer (Cont.)
TM D D D P P C C S
7 7 3 Q D X X A
configuration 5 5 4 1 3 L L P
S S S 1 1
6 6
Tributary unit Line
unit
50 x E1s STM-16 S
l
S
l
S
l
S S
l l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
o o o o o o o o o o o o o o o o o o
4 x E3s t
1
t
2
t
3
t t
4 5
t
6
t
7
t
8
t
9
t
1
t
1
t
1
t
1
t
1
t
1
t
1
t
1
t
1
0 1 2 3 4 5 6 7 8
OptiX OSN
2500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page150
Terminal multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
TM 4 5 5 5 5 X
S S S S S
configuration S S S S S S S S
P
I
P
I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
unit 1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
2 x STM-1e S S S S S S S S
l l l l l l l l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN Fiber Routing
3500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page151
Terminal multiplexer (Cont.)
D D D D E G G P A E D
I
7 7 7 7 O S S U U 3
TM configuration 5 5 5 5 W C C
U
X 0 4
S S S S C C S 8 S
3
S S S S S S S S S S S S S 2 S S S S S
l l l l l l l l l l l l l P
l l l l l
o o o o o o o o o o o o o I o o o o o
Tributary unit Line t t t t t t t t t t t t t U t t t t t
1 2 2 2 2 2 2 2 2 2 2 3 3 S
3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 4 5 6 7 8
unit 3
3
Fiber routing Fiber routing Fiber routing
6 x E3s S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
OptiX OSN
Fiber routing Fiber routing
7500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page152
Add and drop multiplexer
ADM High rate signals
SDH: STM-
1/4/16/64
3 x E3s
Tributary unit Line FAN
PIU Slot 1PIU Slot 11L75S Slot 6
Slot 2PD1 Slot 12L75S Slot 7
unit PL3A Slot 13 Slot 8
CXL16 Slot 4EOW Slot 9
32 x E1s STM-16 Slot 20CXL16 Slot 5
AUX Slot 10
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page154
Add and drop multiplexer
(Cont.)
ADM configuration
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page155
Add and drop multiplexer
(Cont.)
ADM D D D P P C C S
7 7 3 Q D X X A
configuration 5 5 4 1 3 L L P
S S S 1 1
6 6
Tributary unit Line
unit
50 x E1s STM-16 S
l
S
l
S
l
S S
l l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
o o o o o o o o o o o o o o o o o o
4 x E3s t
1
t
2
t
3
t t
4 5
t
6
t
7
t
8
t
9
t
1
t
1
t
1
t
1
t
1
t
1
t
1
t
1
t
1
0 1 2 3 4 5 6 7 8
OptiX OSN
2500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page156
Add and drop multiplexer
(Cont.) D D D D D A
3 7 7 7 7 U
ADM 4 5 5 5 5 X
S S S S S
configuration S S S S S S S S
P
I
P
I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
unit 1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
2 x STM-1e S S S S S S S S
l l l l l l l l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
OptiX OSN Fiber Routing
3500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page157
Add and drop multiplexer
(Cont.) D
7
D
7
D
7
D
7
E G G
O S S
P
I
A E
U U
D
3
ADM configuration 5 5 5 5 W C C
U
X 0 4
S S S S C C S 8 S
3
S S S S S S S S S S S S S 2 S S S S S
l l l l l l l l l l l l l P
l l l l l
o o o o o o o o o o o o o I o o o o o
Tributary unit Line t t t t t t t t t t t t t U t t t t t
1 2 2 2 2 2 2 2 2 2 2 3 3 S
3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 4 5 6 7 8
unit 3
3
Fiber routing Fiber routing Fiber routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page159
Multi-add and drop multiplexer
(Cont.)
MADM configuration
3 x E3s STM-4
Tributary unit Line FAN
PIU Slot 1PIU Slot 11L75S Slot 6
Slot 2PD1 Slot 12 Slot 7
unit PL3A Slot 13
R1SLD4 Slot 8
CXL16 Slot 4
EOW Slot 9
32 x E1s STM-16 Slot 20
CXL16 Slot AUX
5 Slot 10
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page160
Multi-add and drop multiplexer
(Cont.)
MADM configuration
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page161
Multi-add and drop multiplexer
(Cont.)
MADM configuration
D D D P P S C C S
7 7 3 Q D L X X A
5 5 4 1 3 D L L P
S S S 4 1 1
6 6
Tributary unit Line
unit
50 x E1s STM-16 S
l
S
l
S
l
S S
l l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
o o o o o o o o o o o o o o o o o o
4 x E3s STM-4 t
1
t
2
t
3
t t
4 5
t
6
t
7
t
8
t
9
t
1
t
1
t
1
t
1
t
1
t
1
t
1
t
1
t
1
0 1 2 3 4 5 6 7 8
OptiX OSN
2500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page162
Multi-add and drop multiplexer
(Cont.) D D D D D A
MADM configuration 3 7 7 7 7 U
4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
unit 1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
2 x STM-1e STM-4 S S S S S
l l l l l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
S
l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN Fiber Routing
3500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page163
Multi-add and drop multiplexer
(Cont.) D
7
D
7
D
7
D
7
E G G
O S S
P
I
A E
U U
D
3
MADM configuration 5 5 5 5 W C C
U
X 0 4
S S S S C C S 8 S
3
S S S S S S S S S S S S S 2 S S S S S
l l l l l l l l l l l l l P
l l l l l
o o o o o o o o o o o o o I o o o o o
Tributary unit Line t t t t t t t t t t t t t U t t t t t
1 2 2 2 2 2 2 2 2 2 2 3 3 S
3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 4 5 6 7 8
unit 3
3
Fiber routing Fiber routing Fiber routing
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page165
Regenerator (Cont.)
OptiX OSN 2500REG
S S S C C S S S S
configuration L F L R R L F L A
1 1 6 G G 6 1 1 P
6 6 4 4 6 6
CRG:
Timing signal S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
System control t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
& 0 1 2 3 4 5 6 7 8
OptiX OSN
2500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page166
Regenerator (Cont.)
OptiX OSN 2500REG fiber connection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page167
Regenerator (Cont.)
OptiX OSN 3500
High rate signals
SDH: STM-64, STM-16, STM-16
(FEC)
3500
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page169
Regenerator (Cont.)
OptiX OSN 3500 fiber connection as REG & ADM
OSN OSN
3500 OUT IN IN OUT
3500
IN OUT OUT IN
OSN OSN
3500 OUT IN IN OUT 3500
PQ1
SL16 SL16 SL16 SL16
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page170
Common network elements
summary
ADM ADM
MADM
REG
REG STM-64 STM-16
STM-1
ADM ADM
TM
Low-rate signals
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page171
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page172
Equipment Protection
-OSN1500 Items protected Protection scheme
E1/T1 processing board 1:2 TPS
E3/DS3 processing board
E4/STM-1 processing board 1:1 TPS
FE Processing board
Core unit 1+1 hot backup protection
-48V power interface card 1+1 hot backup protection
3.3V card power supply 1:N centralized hot backup protection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page173
Equipment Protection
OSN2500
Items protected Protection scheme
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page174
Equipment Protection OSN2500
(Cont.)
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T 1:4 TPS of E1/T1 board
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
C C S
X X A
L L P
P W W W W
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
2 groups 1:1 TPS for T T T T T T T T
1 2 3 4 5 6 7 8
T
9
T
10
T
11
T
12
T
13
T
14
T
15
T
16
T
17
T
18
E3/T3/E4/STM-1(e)/FE board T C C S T
S X X A S
B L L P B
P W W P
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page175
Equipment Protection
OSN3500
Items protected Protection scheme
E1/T1 processing board 1:N (N 8) TPS
E3/T3 processing board 1:N (N 3) TPS (2 Groups)
E4/STM-1e processing board 1:N (N 3) TPS (2 Groups)
FE Processing board 1:N (N = 1) (2 Groups)
Cross-connect and timing
1+1 hot backup protection
unit
SCC unit 1+1 hot backup protection
-48V power interface board 1+1 hot backup protection
3.3V board power supply 1:N centralized hot backup protection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page176
Equipment Protection OSN3500
(Cont.)
1:8 TPS of E1/T1 board 3 groups of mixed TPS
S S S S S S S S S
S S S S S S S S S S S S S S S S S S S S S S S S S S S
1 1 1 1
L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L
3 4 5 6
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T
E E E E
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 9 1 1 1 1 1
4/ 4/ 4/ 4/
0 1 2 3 4 5 6 7 8 0 1 2 7 8
1 1 1 1
E3 Protection
E3 Working
E1 Working
E1 Working
E1 Protection
5 5 5 5
Working
Protection
Working
Working
Working
5 5 5 5
Working
Working
Working
Working
S S M M M M S S
C C C C
C C W WW P C C
S S S S S S S S S S S S S S S S S S
L 2 3 L L L L L L L L L L L 1 1 L L
O O O O O O O O O O O O 5 6 O O
T T T T T T T T T T T T T T
FE board1:1 TPS 1 4 5 6 7 8 9 1 1 1 1 1 1 1
F F 0 1 2 3 4 F F 7 8
E E E E
X X S S
C C C C
P W S S W P C C
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page177
Equipment Protection
OSN7500
Items protected Protection scheme
E1/T1 processing board 1:N (N 4) TPS
E3/T3 processing board 1:N (N 3) TPS
E4/STM-1e processing board 1:N (N 3) TPS
FE Processing board 1:N (N = 1)
Cross-connect and timing unit 1+1 hot backup protection
SCC unit 1+1 hot backup protection
-48V power interface board 1+1 hot backup protection
3.3V board power supply 1:N centralized hot backup protection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page178
Equipment Protection OSN7500
(Cont.)
1:4 TPS of E1/T1 board 2 groups of mixed TPS
SLSLSLS LS LS S S S S S S S SLOTS S S S S SLSLS LS LS LS S S S S S S S SLOTS S S S S
L L OL OL OL O L L L L L L L L 32 L L L L L L L OL OL OL O L L L L L L L L 32 L L L L L
OTOTOTOTOTO O OTOTOTOTO TO O
PIU(A)
PIU(A)
O O O O O O O O O O O O O O O O O O O O O O
T T1T 1T 1T 1T T T T T T T T T T T T T T T 1T 1T 1T 1T T T T T T T T T T T T T
1 42 52 62 72 82 2 2 2 2 2 3 3 3 3 3 3 3 1 42 52 62 72 82 2 2 2 2 2 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 7 8 9 0 1 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 4 5 6 7 8
SLOT SLOT
S S 33 S S 33
SCC(A)
SCC(B)
SCC(B)
SCC(A)
PIU(B)
PIU(B)
D75S
D75S
D75S
D75S
EU08
EU08
TSB8
D75S
D75S
D75S
D75S
D75S
D75S
D75S
D75S
EOW
EOW
AUX
AUX
C C C
C
Fiber routing Fiber routing Fiber routing Fiber routing Fiber routing Fiber routing
FAN FAN FAN FAN FAN FAN
S S S S S S S S S S S S S S S S SS S S S S S S S S S S S S S S S S SS
L L L L L L L L L L L L L L L L LL L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O OO O O O O O O O O O O O O O O O O OO
T T T T T T T T T T T T T T T T TT T T T T T T T T T T T T T T T T TT
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 11 1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 78 Protection 0 1 2 3 4 5 6 7 8
Protection
Protection
Working
Working
Working
Working
Working
Working
Working
XCS(A)
XCS(B)
XCS(A)
XCS(B)
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page179
Equipment Protection (Cont.)
Fans
The mutual backup of power supplies for the fans
Automatic fan speed adjustment
Once one fan modules goes faulty, the others will operate at their
full speed.
Turns off the fans at low temperature
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page180
Network Level Protections
Protections Types
1+1 MSP
Linear MSP
1:N (1 N 14) MSP
2-fiber bidirectional MSP ring
MSP ring 2-fiber unidirectional MSP ring
4-fiber bidirectional MSP ring
Mesh Protection Intelligent function
SNCP
Dual node interconnection (DNI)
Fiber-Shared Virtual Path Protection
MS-Shared Optical Path Protection
RPR
VP-Ring/VC-Ring Protection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page181
Intelligent Features
Service level agreement (SLA)
Topology automatic discovery function
Automatic end-to-end service configuration
Support mesh networking and protection
Traffic engineering
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page182
Resilient Packet Ring (RPR)
Topology automatic discovery function
Fair algorithm
3 service levels
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page183
Summary
Product Introduction
Cabinet, Sub-rack and Boards
Common Network Elements and Configuration
Features
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page184
Thank you
www.huawei.com