Sie sind auf Seite 1von 43

WCDMA DBS3900

Hardware Structure

In compliance with ISO-9001 Cost Effective Quality Training Manpower Services


References
DBS3900 Product Description
DBS3900 Hardware Description

Page2
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Contents
1. DBS3900 Overview
2. DBS3900 Hardware Structure
3. DBS3900 Networking and Configuration

Page3
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Contents
1. DBS3900 Overview
2. DBS3900 Hardware Structure
3. DBS3900 Networking and Configuration

Page4
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
NodeB in UMTS Network
UE UTRAN CN
Uu Iu

RNC
Iub Iu-CS

NodeB
CS

Iur

NodeB

Iub

NodeB RNC PS
Iu-PS

Page5
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
DBS3900 Overview
DBS3900 components
BBU3900
RRU3804 or RRU3801E
Antenna

TMA
RRU 3804/3801E
RF jumper

Feeder
Grounding Cable
-48V DC
power Power cable RF jumper

BBU3900
-48V/ 24V
DC power Power cable Grounding Cable

CPRI Optical Cable


Trunk cable

RNC

Page6
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
DBS3900 Features
High integrity and large capacity
24 cells
4-carrier configuration
1,536 UL CEs and 1,536 DL CEs
HSDPA,HSUPA and MBMS services
High performance
The 2-way receiver sensitivity 129.3 dBm
PAs Efficiency increase to 40%
Support TX diversity & 4-way RX diversity
ATM/IP dual stack
Multiple clock and synchronization modes
Iub (ATM), IP clock, GPS, BITS
Support RRU cascading

Page7
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Application Scenario
Integrated application (BBU + RRU
+ APM)
New 3G Site
AC power is available
Power backup is required
Features
No need shelter
No need air-conditioner
RRU can be installed on the metal
pole and close to the antenna
Battery power backup, AC/DC
conversion, power distribution, and
Page8 surge protection
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Contents
1. DBS3900 Overview
2. DBS3900 Hardware Structure
1. BBU Module Structure
2. RF Module Structure
3. DBS3900 Networking and Configuration

Page9
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
BBU3900 Physical Structure
BBU3900

Panel & Boards

Page10
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
BBU3900 Logical Structure

Page11
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WMPT Board
Maximum board number: 2
Mandatory, working in active and standby mode
Main functions
Providing OM functions
Controlling other boards and providing the reference clock
Providing USB ports for automatic NodeB upgrading
Providing transmission port for Iub interface

Electrical Port:RJ45 Loading: USB Testing: USB 4E1:DB26 LEDs

O&M:RJ45 Optical Port: SFP GPS antenna: SMA

Page12
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WMPT BoardLED
Labe
Color Status Description
l

ON The board has power input, yet the board is faulty

OFF The board has no power input


Gree 1s ON, 1s
RUN The board is running as configured
n OFF

0.125s ON, The software is being loaded to the board, or the board
0.125s OFF is not in use

ON The board is reporting alarms and is faulty


ALM Red
OFF The board is operational

Gree ON The board is in active mode


ACT
n OFF The board is in standby mode

Page13
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WMPT BoardLED

LED Color Status Description

ON The connections are functional


Green
LEDs OFF The connections are faulty

(link state) Blinking There is ongoing data transmission


Yellow
OFF There is no data transmission

Page14
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WMPT BoardDIP Switch
Settings of SW1
120 E1 75 E1
T1
Bit Balanced Unbalanced
Mode
Mode Mode
1 ON OFF ON
2 ON OFF ON
3 OFF ON ON
4 OFF ON ON

Settings of SW2
Bit 75 E1 Unbalanced Mode Description
1 ON
2 ON The RRING is connected to the protection ground.
3 ON In other modes, all bits of SW2 are set to OFF
4 ON

Page15
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WBBP Board
Maximum board number: 6
Mandatory, work in resource mode
Main functions
Processing uplink and downlink base band signals
3 Cells, UL 128 CE, DL 256 CE
Providing the CPRI interface between BBU & WRRU/WRFU
Supporting 1+1 backup of the CPRI interface between WBBPs

CPRI 0 ~2 (1.25G/2.5G): SFP LEDs

Page16
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WBBP BoardLED
Labe
Color Status Description
l

ON The board has power input, yet the board is faulty

OFF The board has no power input or is faulty


Gree 1s ON, 1s
RUN The board is operational
n OFF

0.125s ON,
Software is being loaded to the board
0.125s OFF

Gree ON The board is operational


ACT
n OFF The board is not in use

OFF The board is operational


ALM Red
ON The board is reporting alarms and is faulty
Page17
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
WBBP BoardCPRI LED
Label Color Status Description

The optical module is not in position, or the CPRI


OFF
electrical cable is not securely connected

Red The optical module or the electrical port is in


ON
CPRI position, yet the received signals are lost

Blinking The associated CPRI link is out of lock

Green ON The associated CPRI link is operational

CPRI LED

In compliance with ISO-9001 Cost Effective Quality Training Manpower Services Page18
UTRP Board
UTRP is the general board name
Configure different sub-board, UTRP provide different interface
Transmissio Sub board Interface type Interface specification
n name
Board
name
WD22UEE WD22UEE FE/GE electrical 2*FE/GE (10/100/1000M adaptive)
U C board
WD22UEO WD22UEO FE/GE optical board 2*FE/GE (10/100/1000M
U C configured)
WD22UAE WD22UAE E1/T1 ATM interface 8* E1/T1
U C sub board
WD22UIEU WD22UPE E1/T1 IP interface 8*E1/T1
C sub board

Panel of
UAEC/UPEC

Page19
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UBFA Board
Maximum board number: 1, mandatory
Main functions
Controlling the fan speed
Reporting the fan status to the WMPT
Detecting the temperature of the fan board

Label Color Status Description


0.125s ON, The module is not
0.125s registered, and no alarm is
Gree OFF reported
STAT n
1s ON, 1s
E The module is operational
OFF
The module is reporting
Red ON
alarms

Page20
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UPEU Board
Maximum board number: 2, mandatory, 1+1 backup
Main functions
Converting -48 V or +24 V DC power input to +12 V DC power
Reporting alarms related to input and output power
Providing transmission ports for RS485 signals and dry contact alarm signals

Panel of the UPEA Panel of the UPEB

-48V +24V

Page21
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UPEU BoardLED & Port
LED on UPEU
Label Color Status Description
ON The board is operational
RUN Green
OFF The board has no power input, or the board is faulty

Port on UPEU
Connector
Label Quantity Function
Type

PWR 1 3V3 DC power input

EXT-ALM1 1 RJ45 Transmitting dry contact alarm


EXT-ALM0 1 RJ45 signals

MON1 1 RJ45 Transmitting RS485


MON0 1 RJ45 environment monitoring signals
Page22
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UEIU Board
Maximum board number: 2, optional
The UEIU functions
Connecting to an external monitoring device and transmitting RS485
signals to the WMPT
Connecting to an external alarm device and transmitting dry contact
alarm signals to the WMPT

Label Connector Type


MON0 RJ45
MON1 RJ45
EXT- RJ45
ALM0
EXT- RJ45
ALM1
Page23
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
BBU3900 Physical Structure
Logical Subsystem Physical Board
Control Subsystem WMPT
Transport Subsystem WMPT/WTRP
Base Band Subsystem WBBP

External alarm device External Monitoring device


WRFU
WRFU
WRFU Power Supply
E1 Cable
RNC
CPRI Cable FE Cable

Page24
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Slot Distribution of the BBU3900
Board Slot 0 Slot 4
Power1
Number Slot 1 Slot 5
Definition FAN
Slot 2 Slot 6
Power0
Slot 3 Slot 7

WBBP/WTR WBBP/WTR
P P UPEU/UEI
WBBP/WTR WBBP/WTR U
UBF P P
Board A WBBP/WTR WMPT
Name & P UPEU/UEI
Position
WBBP/WTR WMPT U
P

Page25
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
SLPU Module (Optional) UFLP
The auxiliary devices of the
BBU3900. The devices are the UELP
SLPU, UELP, and UFLP
SLPU: The signal lightning
protection unit is an optional
module of the DBS3900 cabinet (-
48 V) or the power distribution
cabinet
The UFLP and the UELP are
optional units that are installed in
the SLPU

Page26
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UELP Board (Optional)
The universal E1/T1 lightning protection
(UELP) unit supports the surge protection of 4-
way E1/T1 signals
Can be installed in the SLPU or the BBU

E1
E1

Indoor DDF

Page27
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UFLP Board (Optional)
The universal FE lightning protection (UFLP) board is
optionally installed in the SLPU or BBU
Each UFLP supports 2-way FE surge protection

Transmission
Equipment
FE Cable Connection LAN switch or Router

Page28
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
UELP & UFLP Connection

Page29
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Contents
1. DBS3900 Overview
2. DBS3900 Hardware Structure
1. BBU Module Structure
2. RF Module Structure
3. DBS3900 Networking and Configuration

Page30
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
RRU Logical & Physical Structure

Page31
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
RRU Appearance & Specification
Parameter Value
Dimension 520mm(H) x 280mm(W) x 155mm(D)
( with housing )
Weight RRU module 15KG
RRU module ( with housing )16KG
Power input -48V DC
Power 100W (typical: 1 carrier, 20W, 50%
consumptio load); 275W (MAX)
n
Sector 14(RRU3804)
Carrier 12(RRU3801E)
*.NOTES: The Appearance of RRU3801E (Panel
and Ports) is the same with the that of RRU3804

Page32
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
RRU Panel & Port

Page33
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
RRU LED
Label Color Status Description

RUN Green ON The module has power input, yet the module is
faulty

OFF The module has no power input or is reporting


alarms

1s on, 2s off The module is operational

0.5s on, 0.5s Software is being loaded to the module


off

ALM Red ON The module is reporting alarms (excluding VSWR-


related alarms

OFF The module is operational

TX_ACT Green ON The module is running

OFF No specific meaning

Page34
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
RRU LED
Label Colo Status Description
r
VSWR Red ON VSWR-related alarms are reported
OFF No VSWP-related alarm is reported
CPRI_W Red ON (green) The CPRI link is normal
/ ON (red) The optical module receives local alarms related to LOS
gree
n 0.5s ON, The CPRI is out of lock
0.5s OFF
(red)
OFF The optical module is not in position or is powered off
CPRI_E Red ON (green) The CPRI link is normal
/ ON (red) The optical module receives local alarms related to LOS
gree
n 0.5s ON, The CPRI is out of lock
0.5s OFF
(red)
Page35 OFF The optical module is not in position or is powered off
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Contents
1. DBS3900 Overview
2. DBS3900 Hardware Structure
3. DBS3900 Networking and Configuration

Page36
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
BBU Networking
BBUs and RNC can form multiple networking
modes such as star, chain, tree, and hybrid
For both chain and tree networking modes
cascading levels is less than 5

BBU BBU BBU


BBU

BBU Chain Networking mode


RNC BBU
Star Networking mode BBU
BBU
BBU
RNC BBU
Tree Networking mode

Page37
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
RRU Networking
BBUs and RRUs can form multiple networking modes
such as star, chain, tree, ring, and hybrid
For both chain and tree networking modes
When using the 1.25 G optical module, cascading levels 4
When using the 2.5 G optical module, cascading levels 8

Page38
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Typical Configuration11
Applied to wide areas and indoor
circumstances

RRU

BBU3900

Page39
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Typical Configuration21
Applied to long stretched areas

RRU

BBU3900

Page40
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Typical Configuration31/32
Applied to cities or other high capacity areas

RRU

cities
RRU

RRU

BBU3900

Page41
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Abbreviations
WMPT WCDMA Main Processing and Transmission Unit
WBBPa WCDMA Baseband Process unit Type A
WRFU WCDMA Radio Filter Unit
UBFA Universal BBU Fan Unit Type A (2U)
UEIU Universal Environment Interface unit
UELP Universal E1/T1 Lighting Protection unit
UFLP Universal FE/GE Lighting Protection unit
UPEU Universal Power and Environment Interface Unit
UTRP Universal Transmission Processing Unit
DCDU-01 Direct Current Distribution Unit-01
CPRI Common Protocol Radio Interface
PSU The power supply unit
PMU The power and environment monitoring unit
APM Advanced Power Module

Page42
In compliance with ISO-9001 Cost Effective Quality Training Manpower Services
Thank You