Configuracin de IPA
Para el calculo del IPA detection Bpard Threshold, se tiene que realizar el siguiente calculo:
Se tiene que tomar 2 mediciones en el Puerto IN de la amplificadora EDFA de recepcin mas prximo,
En este caso, el modulo EDFA de la Tarjeta SRAU:
T = (Pa + Pb) / 2
T = (Pa + Pb) / 2
Role in an IPA
Board Type Function
Pair
Control
Controls the on/off status of the laser.
implementation OA board
(Mandatory)
board
Detection board OA board In an IPA pair, either the detection board or
auxiliary detection board or both of them needs
Auxiliary
OTU/OSC/14FIU to be configured as required. (At least one is
detection board
mandatory.)
CRPC01/RAU1/ Provides the laser shutdown function.
Raman amplifier
RAU2 (Mandatory)
Provides only the laser shutdown function. An
auxiliary detection board needs to be
Auxiliary Raman
CPRC03 configured only when the lasers on multiple
board
Raman boards need to be turned off
simultaneously.
Provides only the laser shutdown function. A
Remote pump remote pump board needs to be configured
ROP
board only when the laser on the remote pump board
needs to be turned off.
Para Calibra la funcin ALC y ajustar con precisin la ganancia. Los requisitos previos para la
calibracin las Amplificadoras RAMAN son los siguientes: se crearn conexiones de fibra lgica
y se habr configurado la funcin IPA. Procedimiento para la calibracin.
1. Disable the IPA function and turn off the laser of the upstream Amflier board.
2. Set the working mode of the RAU board to gain locking, and configure the fiber types of the RAU and 14FIU boards to the actual
fibers that are used.
3. Turn on the laser on the LINE port of the RAU board. This step is optional. It is not required when the laser is already turned on.
4. Select the desired LINE port and click Calibrate. If the ASE calibration succeeds, the value of ASE Calibration becomes Calibrated.
5. Turn off the laser on the LINE port of the RAU board, and turn on the laser of the upstream OXU board. Enable the IPA function and
turn on the laser on the LINE port of the RAU board again.
Para un sistema que no se puede configurarse completamente toda las longitudes de onda de servicio en la
fase inicial, los canales vacantes deben llenarse con longitudes de onda que no transportan servicios o la
potencia ptica debe aumentarse para una o ms longitudes de onda que no transportan servicios, para
asegurar que La potencia ptica de entrada de los amplificadores pticos (OAs) satisface los
requisitos del sistema. Las longitudes de onda que no llevan ningn servicio se llaman longitudes de onda
de luz falsas o Dummy Light.
Figure 1 Networking for producing dummy light Figure 2 Networking for producing dummy light (50 GHz
(100 GHz channel spacing) channel spacing)
En el presente escenario, como en el puerto de la ITL estamos conectando al Puerto TE, solo estamos
saturando para un sistema de 40 Canales, si a futuro se quiere saturar a un sistema de 80 Canales, solo se
agregara una Amplificadora entre la ITL y la WSMD9.
Procedure
1. Before adjusting the optical power of wavelengths that carry dummy light, ensure that the
wavelengths that carry service signals provide the optimal performance. For details, see Remotely
Commissioning Optical Power.
2. Set the EVOA attenuation for the M40V board's port connecting to the D40 board to the maximum
value.
3. Set Working Mode to Power Locking for the first-level OA (OBU101) board. And set Power Value
to 0 dBm.
1. In the NE Explorer, select the OBU101 board. In the navigation tree, choose Configuration >
WDM Interface.
2. On the Advanced Attributes tab, set Working Mode to Power Locking.
3. Set Power Value to 0 dBm.
4. Click Apply.
4. Ensure the first-level OA (OBU101) board to forcibly emit light.
1. In the NE Explorer, select the OBU101 board. In the navigation tree, choose Configuration >
WDM Interface.
2. Click Query.
3. Ensure Laser Status for the OUT port on the OBU101 board is On .
5. Adjust the EVOA attenuation for the second-level OA (OAU101) board to the minimum value, and
then adjust the gain to ensure that the total output optical power of the board reaches 20 dBm.
a) Right-click the NE housing the OAU101 board and choose NE Explorer from the shortcut
menu to start the NE Explorer.
b) Select the OAU101 board and in the navigation tree choose Configuration > WDM Interface.
c) Set Optical Interface Attenuation Ratio for the VI port on the OAU101 board to the minimum
value.
NOTE: In the navigation tree, choose Configuration > Optical Power Management. On the right
side of the window, check the value of Input Power, which represents the optical power of the
IN port on the OAU101 board.
d) Click Apply.
e) Set Nominal Gain to 23dB (adjust the gain value according to the actual optical power), and
ensure that the total output optical power of the board reaches 20 dBm.
f) Click Apply.
6. Set the EVOA attenuation to 5 dB for the wavelength that carries dummy light next to the wavelength
that carries service signals on the M40V board.
7. Fine-tune the EVOA attenuation for the wavelength that carries dummy light and other wavelengths
that carry service signals on the M40V board to ensure that the board provides the optimal optical
power balancing among the wavelengths.
8. Repeat 6 through 7 to adjust the optical power of the remaining wavelengths that carry dummy light
one by one to ensure that the system will be able to provide the optimal performance when a
maximum of wavelengths are provisioned.