3G KPI RCA

INTRODUCTION

RRC
RAB
DCR SPEECH
CS IRAT
PS IRAT

Amit Kumar Srivastav | 2012-06-28 | Page 2


RRC

Amit Kumar Srivastav | 2012-06-28 | Page 3


Reasons of RRC Fail
Due to Code Utilization

Due to Power Utilization

Due to DL/UL Hardware

Due to MP Load

RRC requests denied by admission control due to insufficient licensed capacity


in the RBS

RRC Setup Failure after Admission

RRC Connection Setup attempts for CS/PS calls that fail due to node blocking.

RRC Connection Setup attempts for CS/PS calls that fail due to Transport
Network blocking

Amit Kumar Srivastav | 2012-06-28 | Page 4


Recommendations
To reduce Code Utilization need to Increase dlcodeadm parameter.

To reduce Power Utilization Increase pwradm, upgrade license capacity.

To reduce DL/UL Hardware Utilization need to Increase dlhwadm/ ulhwadm, add


extra RAX cards.

To reduce MP Load need to add GPB cards.

To increase insufficient licensed capacity in the RBS need to Upgrade CE


License Capacity.

For RRC Setup Failure after Admission need to check Transmission Media ,
AAL2 failure, Iub congestion etc.

To resolve node blocking issue need to check Transmission Media , AAL2


failure, Iub congestion etc.

To resolve Transport Network blocking issue need to check Transmission


Media , AAL2 failure, Iub congestion etc.
Amit Kumar Srivastav | 2012-06-28 | Page 5
RAB

Amit Kumar Srivastav | 2012-06-28 | Page 6


Reasons of RAB Fail
Due to insufficient UE capabilities
Due to lack of DL/UL ASE
Due to lack of DL channelization codes
Due to lack of DL power
Due to lack of Dl/UL hardware resources
Due to TN congestion or TN failure for CS/PS RABs
Due to node congestion or node failure for CS/PS
RABs
RAB establishments rejected by admission control for
CS/PS RABs

Amit Kumar Srivastav | 2012-06-28 | Page 7


Solutions
For insufficient UE capabilities need to check the Hand set class.

Due to lack of DL/UL ASE need to increase asedladm/


aseuladm.

Due to lack of DL channelization codes need to increase


dlcodeadm.

Due to lack of DL power need to increase pwradm, upgrade


license capacity.

Due to lack of Dl/UL hardware resources inc dlhwadm/ulhwadm,


add extra RAX cards.

Due to TN congestion or TN failure for CS/PS RABs Transmission


check req, Iub congestion etc.
Amit Kumar Srivastav | 2012-06-28 | Page 8
DCR
SPEECH
Amit Kumar Srivastav | 2012-06-28 | Page 9
Reasons of DCR
Drop call due to Congestion
Drop call due to IRAT
Drop call due to Missing NBR
Drop call due to Soft Handover
Drop call due to Uplink Sync
Drop call due to Other

Amit Kumar Srivastav | 2012-06-28 | Page 10


Solutions
Need to Check RSCP/ECNO by Drive test
Need to Check Pilot Pollutions area
Need to Check Propagation delay for overshooting
Need to Check Missing NBR (Check NBR plan)
Need to check Alarms,VSWR
Need to Check Transmission issue(DIP issue,AAL2
failure,etc)
Need to check IRAT issue (Check 2G NBRs)
Need to Check Hardware issue.
Need to check CE,Power&Code utilization
Need to check Outages
Amit Kumar Srivastav | 2012-06-28 | Page 11
CS IRAT

Amit Kumar Srivastav | 2012-06-28 | Page 12


Reasons of CS IRAT Failure
Wrong 2G BSIC,BCCH,CGI,etc definitions in RNC
Wrong 2G LAC definitions in MSC.
2G Cell Is Having High Interference
2G Cell having High TCH Utilization
2G Cell having Hardware issue
2G Cell having alarms

Amit Kumar Srivastav | 2012-06-28 | Page 13


Solutions
Proper definitions required for 2G
BSIC,BCCH,CGI,etc in RNC
Remove discrepancies of 2G LAC definitions in
MSC.
Frequency check required to overcome the
interference
Need to identified high TCH utilized 2G cell
Hardware issue need to check in 2G Cell
Alarm issue need to rectify in 2G Cell
Proper neighbor tuning required for IRAT
Amit Kumar Srivastav | 2012-06-28 | Page 14
PS IRAT

Amit Kumar Srivastav | 2012-06-28 | Page 15


Reasons of PS IRAT Failure
Wrong 2G BSIC,BCCH,CGI,etc definitions in
RNC
Wrong 2G RAC definitions in SGSN.
2G Cell Is Having High Interference
2G Cell having High data Utilization
2G Cell having Hardware issue
2G Cell having alarms
2G cell having high 64K abis rejection
2G cell having Soft Blocking & Hard Blocking

Amit Kumar Srivastav | 2012-06-28 | Page 16


Solutions
Proper definitions required for 2G
BSIC,BCCH,CGI,etc in RNC
Remove discrepancies of 2G RAC definitions in
SGSN.
Frequency check required to overcome the
interference
Need to identified high data utilized 2G cell
(Increase FPDCH)
Hardware issue need to check in 2G Cell
Alarm issue need to rectify in 2G Cell
Proper neighbor tuning required for IRAT
Amit Kumar Srivastav | 2012-06-28 | Page 17