Sie sind auf Seite 1von 28

TRAINING ON

BOILER SYSTEM DISCRIPTION

BANGAAI AMMONIA PLANT (BAP)


By Mr. PRASHANT M. PATIL
GAS FIRED FM BOILER
BANGAAI AMMONIA PLANT (BAP)

TRAING ON OPERTION AND MAINTENANCE


OF FM BOILER
GAS FIRED FM BOILER

BOILER SALIENT FEATURES


FM means Fully Modular
Packaged, shop / site assembled & fully modular boilers
Bi-drum, bottom supported design with
water cooled furnace.
Suitable for firing : Natural gas firing
Fully drainable super heater
Drum coil pre-heater to increase feed water inlet
temperature to Economizer
GAS FIRED FM BOILER

BOILER SALIENT FEATURES


Fully drainable superheater

High efficiency steam separators

Drum coil pre-heater to increase feed water inlet


temperature to Economizer
GAS FIRED FM BOILER

GAS FIRED BOILER FEATURES


MCR 68TPH

Steam Pressure 46.9 Kg/cm2 (g);

Design Pressure 57.5 Kg/cm2 (g);

Steam Temperature 387 C

Design ASME SECTION I EDITION 2013

Performance Testing ASME PTC 4.1(Heat Loss Method)

Design Fuel- Natural Gas


GAS FIRED FM BOILER
Typical
Steam
Sectional View
Drum

Superheater

Convection bank

Membrane
Furnace Wall

Outer Casing
Water
Wind Box
Burner Drum
GAS FIRED FM BOILER
Water Circulation circuit
GAS FIRED FM BOILER

Flue Gas Path


GAS FIRED FM BOILER

P&ID DESCRIPTION:
Steam & Water:
Components:
Boiler Feed Water Control Station
Drum Coil Pre-heater
Economizer
Boiler (Steam Drum, Evaporator, Water Drum)
Superheaters (HP & MP Superheaters)
De-super heater
Main Steam Piping
GAS FIRED FM BOILER

Boiler Feed Water Control Station:


Function of feed water control station is to maintain the water level in
the boiler steam drum.
Feed flow control station consist of
1 x 100% Control valve
1 x 30% Control valve
Manual isolation valve at inlet and outlet for 30% and 100% control
valves.
Manual bypass globe valves are provided at 30% control valves and
100% Control valves.
Pressure and temperature indicators
Flow measurement with transmitter
One Nos Temperature Control valve is provided at Feed water
control station outlet to control Economizer inlet temperature.
GAS FIRED FM BOILER

Drum Coil Pre-Heater:

Boiler is provided with a drum coil heater inside the water drum. The
heater is a heat exchanger in which the feed water from the feed
water control station passes through the tubes picking up heat from
the drum water

Heat that is picked up from the coil heater ensures that the feed
water temperature at the inlet to the economizer leads to a flue gas
temperature greater than the sulphur dew point temperature.
GAS FIRED FM BOILER
GAS FIRED BOILER

Economizer:
To recover economically feasible heat from the flue gas.

It increases the temperature of feed water entering into the Steam


Drum.

Counter flow design for optimum heat recovery

The coils are made of SA 210 GrA1 material and of size mm OD


38.1 * 3.25 mm thick

The headers are made of SA 106 Gr B material


GAS FIRED FM BOILER

Steam Drum:
Steam drum Accommodates
Feed pipe
Continuous blow down line
H.P. dosing pipe
Cyclone Separators
Primary and Secondary Scrubbers
GAS FIRED FM BOILER

Steam drum Mountings


Level Gauges (2 Nos.)
Level Transmitter (4 Nos.)
Pressure Gauges on Steam Drum Puppy Header
Pressure Transmitter on Steam Drum Puppy Header
Safety Valves (2 Nos.)
Air Vent with isolation valve on Steam Drum
GAS FIRED FM BOILER
GAS FIRED BOILER

Convection Bank :
Convection section consists of Convection Banks . Each Convection
bank consists of set of SA 210 Gr A1 plain tubes (50.8 mm OD &
3.66 mm Thk.), with their ends fitted duly to the bottom and top
drums of the Evaporator (twin drum type)

Water drum:
The Water or the Mud drum is provided with the intermittent blow
down (IBD) connection.
Water drum accommodates:
Intermittent Blow down Connection MOV
Drum coil Pre-heater
GAS FIRED BOILER

HP Superheater:
TheSuper heater section is divided into five passes:
HPSH pass I (SA 210M Gr A1 T22 & 50.8 mm OD / 4.5 mm Thk)
HPSH pass II &IV (SA 213M T11 & 50.8 mm OD / 4.5 mm Thk)
HPSH pass III &V (SA 213M T22 & 50.8 mm OD / 4.5 mm Thk)
GAS FIRED BOILER

De-Superheater (Attemperator):
Spray type Attemperator assembly is provided Between PSH &
SSH to control final stem temperature.
Water is sprayed through the spray nozzle along the steam flow
direction.
Construction of the sleeve along with the spray nozzle facilitates
proper mix up of water with steam.
Spray water through temperature control valve.
GAS FIRED BOILER

Main Steam Line:


Temperature Elements
Safety Valve (1-no.)
Pressure Transmitters & Indicator
Flow Element with Flow Transmitters
Start up Vent
Main Steam Stop Valve
Non Return Valve
GAS FIRED BOILER
OFF GAS FIRED BOILER

Air & Flue Gas:


Components:
FD Fans (Motor Driven & Turbine Driven)
Air Duct
Combustor
Flue Duct
Stack Inlet multi-lower damper
Stack
GAS FIRED BOILER

FD Fan:
One Motor driven FD Fan with 100% capacity provided.
Supply of combustion air to the boiler.
Forcing product of combustion through the boiler, economizer & to
the stack.
GAS FIRED BOILER

FD Fan (2631-ME-007-K1B) Motor Driven:


Duty conditions Unit FD Fan (Test Block Condition)
Make Howden Solyvent
Quantity No. 1 x 100%
Nature of medium Clean Air
Airflow Rate M3/sec 20.72
Static Head Inlet / Outlet Mmwc -35 / 715

Air Temperature at Fan Inlet Deg C 37

Inlet Density Kg/m3 1.11


Fan Shaft Power with Full
KW 199
Damper Opening
Fan Speed Rpm 1480

Bearing Lubrication ISO VG 46 or Equivalent Oil


225 kw, 4P 1411 RPM Crompton
Motor
Greaves motor
Coupling SPACER Type Metaflex 80X SPL, Size
Model / Make 262
GAS FIRED BOILER

Scanner Air fan


Duty conditions Unit SC Fan (Test Block Condition)
Make Howden Solyvent
Quantity No. 1 Working + 1 Stand by
Nature of medium Clean Air
Airflow Rate M3/sec 0.1857
Static Head Inlet / Outlet Mmwc -43 / 740
Air Temperature at Fan Inlet Deg C 37
Inlet Density Kg/m3 1.293
Shaft Power (Damper Control) KW 3.69

Fan Speed Rpm 2900


Bearing Lubrication ISO VG 46 or Equivalent Oil
225 kw, 4P 1411 RPM Crompton
Motor
Greaves motor
Coupling SPACER Type Metaflex 80X SPL, Size
Model / Make 262
GAS FIRED BOILER

Air Ducts:
FD fan Discharge connected wind box through air duct.
One Para flow modulating damper provided at wind box inlet
A pressure Transmitter is provided in Air duct and wind box to
measure the pressure.
One Aerofoil is provided to measure the combustion air flow.
Air flows into furnace through Air sleeve damper mounted on
burners.
GAS FIRED BOILER

Flue Gas Duct:


Flue gas from the furnace passes through Screen Tubes, SH coils,
Evaporator tubes, Boiler Feed Water Preheater (Economizer) coils
and finally on stack.
Temperature and pressure indicators
Pressure Indicator is provided at secondary SH outlet
Temperature Transmitter with indicator provided at SH outlet
Flue gas Temperature at Economizer Outlet
Flue gas temperature at Economizer outlet
O2 Measurement at Economizer outlet provided
Multi lower damper at stack inlet.
OFF GAS FIRED BOILER

THANK YOU !!!

Das könnte Ihnen auch gefallen