Sie sind auf Seite 1von 13

Carl Zeiss Industrial Metrology Group

Technical Information EDM Module

Calypso
Prerequisite

Adjustments General
EDM Information
File Conf.dat
Example

Supported Interfaces
EDM Systems

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

The user needs: Y

The offset and the rotation of an X

electrode (A) to a chuck (B).

What the user makes available:


- a high-exact chuck on the
B
CMM (B)
- a same chuck in the EDM
machine
- an electrode (A) with attachment
(C) for the chuck A

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

General
Every CMM user can generate
offset Data for EDM operation C

Case A Y

The CMM generates offset information X

(X,Y, Z and Rotation angle C),


Results are entered manually into
EDM System
- Pro: no interface necessary
-- Con: time consuming and prone to operator typing error

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

Case B
Step1
CMM generated offsets are transmitted automatically via
interface to EDM controller.

The Special Option EDM in UMESS UX, Calypso or


ScanWarePRO main function is:
Save values of 2 different Coordinate Systems to an ASCII-file
with a given file name ERODIER. EDM

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module
Case B
Step 2 ( This step occurs automatically each time of arrival of
new file to Controller of EDM System)

- The Program EPOST.EXE calculates from both coordinate systems the


Offset X,Y.Z and Rotation Angle C and additional into an ASCII-file of selected
EDM system  

- This EDM–file recognizes Controller of EDM System


 
- The only necessary input by Operator is the Type of EDM
System and File-name. (EPOST.EXE acts automatically)

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module with Calypso
Calypso
1. Option EDM
2.
( available > version 4.6)
Operator selects:
Establishing of 2 Coordinate

System -  -- Coordinate System Chuck of


Electrode Holder
-   - Coordinate System Electrode 3.
-   - Directory and name of output file
-    - Name of Electrode
-   - Type of EDM System
-   - Program Module to generate EDM
information

4.
Epost.exe 5. Steps 4. and 5. are
Sends - calculates contents done automatically
ASCII-File of output file
Erodier.edm -stores output file
24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module with Calypso

Example for input in Calypso

Preparing- 
  Assistance
  EDM –Module
Or by using Toolbox, Insert
EDM-Module in Inspection plan

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module
Example for one of the different interfaces definitions

Y0

Y
X0
X

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

Supported EDM Manufacturers


•MaschName1=Charmilles •MaschName11=Walter Exeron
•MaschName2=Zimmer & Kreim •MaschName12=AEG Elotherm
•MaschName3=Mitsubishi •MaschName13=Charmilles N
•MaschName4=SGL •MaschName14=Jung
•MaschName5=Hansen •MaschName15=AGIE Evolution
•MaschName6=AEG Elotherm S •MaschName16=EMT
•MaschName7=Makino •MaschName17=Multiform
•MaschName8=Agie •MaschName18=System 3R
•MaschName9=Maho-Hansen •MaschName19=FANUC
•MaschName10=Ingersoll

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

Example Interface Agie or Zimmer & Kreim

In file Conf.dat the switch settings of 8 ( 0 or 1) determines


the output information
 ( Sign, applying or not applying C…….see example below)

File Conf.dat

(AGIE-Format- stored in
C:)\TEMP\AGIE\)

24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

Conf.dat Influence to the results 2


File Conf.dat
In file Conf.dat the switch settings of 8 ( 0
or 1) determines
the output information
 ( Sign, applying or not applying C…….see
example below)
Attention!
A 1 at the 5. position works like
trading of the coordinate-systems
X‘
X‘ 0
Y‘ 0 = -C‘

Y‘

Both results were generated with the same File


erodier.edm
24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

Conf.dat Influence to the results 2


Examle Agie with EPOST.EXE Rel. Date March 5, 2002

1. 2. 3. 4. 5. 6. 7. 8.

00000000
0 ELEKEle,M,-38.611,34.783,50.242,-7.740;
| | | | | | | |_ 8. code Electrode / workpiece*
1 WKSEle,M,-38.611,34.783,50.242,-7.740;
| | | | | | |_ 7. free
| | | | | |_ 6. free
| | | | |_ 5. basic (1 exchanges basic system !) 0 ELEKEle,M,-38.611,34.783,50.242,-7.740;
1 ELEKEle,M,-42.944,29.266,50.242,7.740;
| | | |
| | | |_ 4. +/- C (1 exchanges +/- C)
| | |_ 3. +/- Z (1 exchanges +/- Z)
| |_ 2. +/- Y (1 exchanges +/- Y)
|_ 1. +/- X (1 exchanges+/- X)

always stored in C:\TEMP\Agie \


Each measurement gets a directory? Title: ELE-1.....i or WKS-1....i
File Name: MESSDAT.ASC
24.07.02/ Ggi
Carl Zeiss Industrial Metrology Group
Technical Information EDM Module

Conf.dat Influence to the results 3


Example Agie Evolution with EPOST.EXE Rel. Date March 5, 2002

1. 2. 3. 4. 5. 6. 7. 8.

00000000
| | | | | | | |_ 8. code Electrode / workpiece* 0 ELEKEle,M,-38.611,34.783,50.242,-7.740;
| | | | | | |_ 7. free 1 WKSEle,M,-38.611,34.783,50.242,-7.740;
| | | | | |_ 6. free
| | | | |_ 5. basic (1 exchanges basic system !)
0 ELEKEle,M,-38.611,34.783,50.242,-7.740;
| | | | 1 ELEKEle,M,-42.944,29.266,50.242,7.740;
| | | |_ 4. +/- C (1 exchanges +/- C)
| | |_ 3. +/- Z (1 exchanges +/- Z)
| |_ 2. +/- Y (1 exchanges +/- Y)
|_ 1. +/- X (1 exchanges+/- X)

Stored at ....\Agie.mes
Each measurement generates another line at the end of the files Agie.mes

24.07.02/ Ggi