Solutions
for
Wastewater Treatment and Disposal
“The significant problems we face today
cannot be solved at the same level of
thinking we were at when we created
them”
Albert Einstein
WASTE MANAGEMENT HIERARCHY
Treatment
Disposal
Challenges
• Quality requirements
• Energy requirements
• Land requirements
SECONDARY TREATMENT
- BIOTOWER FEED SUMP
- BIOTOWER
- AERATION TANK
- SECONDARY CLARIFIER
-GUARD POND
-CHEMICAL DOSING SYSTEMS
EMULSIONS PLANT- WATER BALANCE
• SOLID WASTE FROM ETP (1 M3/DAY) & RMS : 0.5 TPD (85% DRY SOLIDS)
FOR LANDFILL
• WATER RECOVERED = 127 M3/DAY, 115 M3/DAY USED AS WTP FEED &
12 M3/DAY USED AS BOILER FEED
CONDENSATE
10 M3/D
DOMESTIC
28 M3/D
SOLIDS FOR DISPOSAL
COOLING
RAW WATER FROM 103 M3/D 48 M3/D TOWER
BOREWELL 126 M 3/D WATER TREATMENT PLANT MAKE UP
87 M3/D (WTP)
88 M3/D
PROCESS &
RO REJECT
MGF BACKWASH
PF BACKWASH
UTILITIES
RO PERMEATE FOR
RO PERMEATE
RO REJECT
3 M3/D
UF BACKWASH
25 M3/D
SLUDGE
6 M3/D
5 M3/D
11 M3/D
RO PERMEATE
TO BOILER MAKEUP 99 M3/D
12 M3/D 15 M3/D
BOILER & CT BLOWDOWN
WASTEWATER TREATMENT PLANT
8 M3/D
DRY SLUDGE (WWTP) DOMESTIC EFFLUENT
TO SECURED LANDFILL 1M3/D PROCESS EFFLUENT
55 M3/D
DETAILS OF WTP - EMULSIONS PLANT
- HRSCC
• RO REJECT (197 M3/D) & SLUDGE (100 M3/D) FROM ETP SUBJECTED TO EVPORATION
(290 M3/D OF CONDENSATE RECOVERED USED FOR PROCESS)
DM
GREEN BELT SURFACE DRAIN FROM PLANT PLANT
50 M3/D
350 M3/D
1070 M3/D
10 M3/D
100 M3/D 865 M3/D UTILITY
IRRIGATION COOLING BOILER
EFFLUENT
WATER TOWER
COLLECTION
SUMP
SUMP
1025 M3/D
925 M3/D
2095 M3/D
BACKWASH
100 M3/D
786 M3/D
290 M3/D
1076 M3/D
RECYCLED TO PROCESS SOLIDS 5.8TPD