Built on Durability
– Based on tough Altair 4 Multigas Detector
Powered by Performance
– New High Performance XCell™ Sensors
XCell Technology
Typical life >= 4 Years
– 60% longer sensor life than the industry average
– Standard 3 year warranty
Benefit
– Higher performing sensors with greater stability
XCell O2 Sensor Life
Most Other O2 Sensors (Typical Life <= 2 years)
– Use a consumable chemical reaction
– Filled with lead which is converted to lead oxide
– Sensor dies as lead is depleted (limited shelf life)
Displays:
– Instrument name
– Software version
– Combustible gas type
– Toxic units (ppm or mg/m3)
– Alarm set points (Low, High, STEL, TWA)
Start Up
Displays expected
calibration gas concentrations
Shows current time and date
Indicates last successful cal. date
Indicates next cal. date (if activated)
Shows measurement countdown
Offers fresh air setup option
Defaults to measurement page
Pages
Measurement (default)
Bump
Peak readings
Minimum oxygen reading
STEL for toxics (if activated)
TWA for toxics (if activated)
Time
Date
MotionAlert™ feature
Data Log
Event logging (500 events)
– Gas and battery alarms
– Calibration & bump records
– Battery voltage
– FAS, re-zero, calibration
– Reset of TWA, STEL & Peak
Gas records(>50 hours)
– Reading
– Time and date
– Peak, Min, Average
– Temperature
Graphs & tables
Infrared-based MSA Link Software-compatible
– Change instrument settings
Last successful calibration date
Setup
Password-protected access
Change:
– Individual sensor channels
– Combustible gas type
– Auto calibration values
– Calibration due on/off
– Alarm set points
– Low, High, STEL, TWA
– Date
– Time
Other settings through MSA Link Software
Calibration
Single-button auto cal-based
– Access can be password-protected
Same Altair 4 & Solaris Detector
®
calibration cylinders
– 1.45% CH4
– 60 ppm CO
– 15% O2
– 20 ppm H2S
• 10048280 (34L)
• 10045035 (58L)
Calibration
1. Press and hold ▲ button
2. Instrument prompts user to “Zero Cal?”
3. Press to accept & initiate zero function
– Or press ▲ to cancel function
4. Unit will automatically zero sensors
– Zero pass
5. Instrument prompts user to “Span Cal?”
6. Attach cal. cap & flow cal. gas to instrument
7. Press to accept & initiate span
– Or press ▲ to cancel function
8. Unit automatically spans sensors
Accessories
Galaxy® Automated Test System
– Bump test and calibration
– Record keeping
QuickCheck® Station
– Bump test only
– Records activities
Charging cradle
Multi-Unit Charger
– Up to 10 instruments
Thanks!