Sie sind auf Seite 1von 19

Energy Auditing Proposal Scope of Work

Energy Modeling at RAKRIC


Orientation

Solar Insulation
System

Modeling
Lighting HVAC

Glazing Shading
Insulation Materials
- Modeling of different insulation materials with
several U- Values.

- Modeling of Insulation effect on roof + wall.

- Optimum U-Values (after certain point the


decrease of U-Value will not show significant
performance enhancement).
Glazing
Technologies
Modeling of A Villa in
RAK
2D sketches

Left side view

Top view

Rear view
3D dimensional View

Front view
3D dimensional View

Left side view


3D dimensional View

Rear view
3D dimensional View

Right side view


Modeling Considerations &
Assumptions
Assumption
Number of Operation Days/ Year 365 (Full Year)
Number of Hours HVAC is ON 24 Hours
Number of Hours Lighting is ON 15 Hours
HVAC System Set Point 23 C
Number of Hours Exterior Lights ON 9 Hours

- Other required assumptions such as: infiltration, air tightness, occupancy,


HVAC Efficiency were assumed to be according to ASHRAE 90.1 standards
(eQuest Defaults)
Current Situation at the Villa (Original Building):

- U-Value of Buildings’ Walls (current)= 0.71 W/ m2 K.


- U-Value of Buildings’ Roofs (current)= 0.356 W/ m2 K.
- U- Value of Glazing (Double Glass) (current)= 2.7 W/ m2 K.
- Split AC units are used to cool the building (Ducted+ Direct)

Results (Original Building Design):


Application Electricity Consum. / Year (KWh)
HVAC 21,520
Lighting (Interior+ Exterior) 11,960
Domestic Hot Water 5,190
Other Electrical Eq. 8,410
TOTAL
47,080
Proposed Solution NO. 1:
- In this trial we changed wall U- Value from 0.71 W/ m2 K, to 0.32 W/ m2 K.
- Everything else remained the same.

Application Electricity Consum. / Year (KWh)


HVAC 20,571
Lighting 11,960
Domestic Hot Water 5,190
Other Electrical Eq. 8,410

TOTAL 46,131
Proposed Solution NO. 2:
Here we will change both U- Value of Walls + U- Value of Roof as follows:

U- Value of Walls= 0.32 W/ m2 K

U- Value of Roof= 0.2839 W/ m2 K

Application
HVAC 19,770
Lighting 11,960
Domestic Hot Water 5,190
Other Electrical Eq. 8,410

TOTAL 45,330
Proposed Solution NO. 3:
• Here we will change both U- Value of Walls + U- Value of Roof + We Will Add Shadings to the
windows as follows:
U- Value of Walls= 0.32 W/ m2 K
U- Value of Roof= 0.2839 W/ m2 K
Shadings on all windows (Over Hangs):

Application Electricity Consum. / Year (KWh)


HVAC 18,571
Lighting 11,960
Domestic Hot Water 5,190
Other Electrical Eq. 8,410
TOTAL 44,131