Agenda
• What is DWDM ? How it is different ?
• Components of DWDM network.
• Conventions followed.
• Handling DWDM Components.
• Tejas DWDM platform and cards.
• Commissioning DWDM link.
3
©Tejas Networks Proprietary & Confidential
Typical DWDM network
4
©Tejas Networks Proprietary & Confidential
Tejas DWDM Channel Plan
• Compatible with ITU-T G. 694.1
• Tejas DWDM grid support from 192.00 THz to 195.95 THz at 50GHz
spacing (80 Ch). In Future it can be extended to 191.60 THz (88 Ch).
5
©Tejas Networks Proprietary & Confidential
Tejas Channel conventions
• Tejas software and cards uses last three digits of
the ITU-T frequency to represent the channel.
• For example:
– Channel 1550.12nm(193.40 THz) is represented as
340, similarly Channel 1536.21nm(195.15Thz) is
represented as 515.
6
©Tejas Networks Proprietary & Confidential
Handling DWDM components and Safety
Precautions
Handling DWDM components and
Safety Precautions!
• DWDM network elements involves more optical
components.
• High optical power levels.
8
©Tejas Networks Proprietary & Confidential
Inspect the Connectors before
connecting
• Ensure fibers and connectors are
cleaned before connecting to the
optical device.
– loss of light or degraded signal power.
– Damage to connector end face.
10
©Tejas Networks Proprietary & Confidential
Handle fibers gently
• Do not bend the fiber cable. Bending the
cable may cause Loss of signal or internal
breaks along the fiber resulting in poor
performance.
• Ensure dust caps are put on the fiber ends
when not in use.
• Do not allow the end of the fiber optic cable
to make contact with any surface including
fingers.
11
©Tejas Networks Proprietary & Confidential
Cleaning procedure
• Place 1-3 drops (shake-off if excess
amount fell on tissue paper) of fresh
methanol/isopropyl alcohol on Fresh lint
free tissue paper.
• Hold the fiber by the connector or cable as
shown in the Figure.
• Place the wet portion of the tissue paper
on the optical surface and slowly drag it
across (do not apply extra force).
• Don’t retrace cleaning path.
• Immediately place dust cap over the end
of the interface to avoid re-contamination
or insert the fiber for immediate use.
• Don’t reuse tissue papers.
Cleaning procedure cont.…
• Connector cleaning.
• Always use fresh Cletop stick
(cleaning bud) for cleaning
connectors.
• Place 1-3 drops of fresh
methanol/isopropyl alcohol on
cleaning bud.
• Gently insert wet cleaning bud in to
the connector and rotate it in clock
wise direction(2 – 3 rounds).
• Immediately place dust cap over the
connector to avoid re-contamination
or insert the fiber for immediate
use.
• Don’t reuse Cletop sticks
Do’s and Don’ts
• Only fresh (dry) Methanol or Isopropyl Alcohol should
be used as a cleaning solvent (Don’t use any other
solvent than proposed one for cleaning, not even
acetone, that may spoil pachcord/adapter and even
optical modules).
• Use only fresh and lint free tissue papers for cleaning
(like Kim-wipes, don’t use normal tissue paper or
anything unauthorized).
• Don’t reuse tissue papers.
• Clean the surface gently( do not apply extra force).
• Don’t retrace cleaning path.
• Don’t use excess amount of alcohol for cleaning.
Tejas DWDM Platform
Tejas DWDM platform
POTP+DWDM[TJ3500]
POTP+DWDM[TJ3310]
16
©Tejas Networks Proprietary & Confidential
Tejas DWDM cards
• OSMC(Optical Shelf Management Controller).
• Transponder/Muxponder card.
• Adapter cards.
• MDU(Mux and Demux unit).
• OADM(Optical Add Drop Multiplexers).
• OFA (Optical Fiber Amplifiers).
• ILU(Inter Leaver Unit).
• DCM(Dispersion Compensation Modules).
• PSCM(Power Splitter Combiner Module).
• ROADM(Reconfigurable Power Splitter Combiner Module).
• OPM(Optical Power monitoring ).
17
©Tejas Networks Proprietary & Confidential
OSMC(Optical Shelf Management Controller).
OSC ports
18
©Tejas Networks Proprietary & Confidential
OSC with Adapter
• Not a full slot width card.
• In TJ1660-11 OSMC01 unit fits in slot 5 and slot 6 of the
chassis (with mechanical adaption only).
• For TJ1600-6 it can be used in 9th and 10th slot directly.
19
©Tejas Networks Proprietary & Confidential
Transponder/Muxponder cards
Transponder
20
©Tejas Networks Proprietary & Confidential
HCPSLine08
Muxponder
21
©Tejas Networks Proprietary & Confidential
CEF-3
22
©Tejas Networks Proprietary & Confidential
Adapter cards
• Optical Adaptor Card, Supports 1/2 and 1/2 slot cards
23
©Tejas Networks Proprietary & Confidential
Mux and Demux unit-8
• MDU-8 (Mux and Demux Unit)
– 2/3rd slot card.
– Needs to be used with the HCPADP01 (2/3+1/3)
adaptor cards.
– 5 of MDU-8-D covers from 192.00 THz to 195.90
THz.
24
©Tejas Networks Proprietary & Confidential
40 Channel Mux Demux unit
• 1RU External Sub Rack unit.
• Purely Passive. No Inventory Management
functionality.
• MDU-40E-100G
•
• MDU-40O-100G
25
©Tejas Networks Proprietary & Confidential
Dispersion Compensation
module(DCM)
Rx port
Tx port
DCM verities
DCM-652-C-40-CB
DCM-652-C-60-CB
DCM-652-C-80-CB
DCM-652-C-100-CB
DCM-652-C-120-CB
26
©Tejas Networks Proprietary & Confidential
Power Splitter Combiner Module
• 1RU External Sub Rack unit.
• Purely Passive. No Inventory Management
functionality.
Port 2Rx Tx Port 4Rx Tx common Rx Tx
27
©Tejas Networks Proprietary & Confidential
Adding Rack shelf to the node
28
©Tejas Networks Proprietary & Confidential
4 Channel OADM
• MDU-8 (Mux and Demux Unit)
– 2/3rd slot card.
– Needs to be used with the HCPADP01 (1/2+1/2)
adaptor cards.
– 10 of OADM covers from 192.00 THz to 195.90
THz.
29
©Tejas Networks Proprietary & Confidential
Inter Leaver Unit
• Ports:
– Port1:- Even and Odd
– Common(Rx/Tx)
• All ports are bidirectional.
30
©Tejas Networks Proprietary & Confidential
Optical amplifer cards
• Single Port optical amplifier
31
©Tejas Networks Proprietary & Confidential
Amplifier Ports
Monitor port
Port 1 Tx Port 1 Rx
32
©Tejas Networks Proprietary & Confidential
Ofa card UI
33
©Tejas Networks Proprietary & Confidential
OFA card UI settable parameters
• Operational mode:- AGC and APC.
• Form DWDM application always make sure that operational mode is
set to Automatic Gain Control (AGC).
• Amplifier Tilt:- Applicable only for VG type
Amplifiers. It sets the gain tilt set by the amplifier.
Range +2 to -2 dB.
• Set amplifier Gain:- gain value to be achieved.
• LOS threshold:- Threshold value below which LOS
is declared.
• LOS deviation :- Hysteresis value For LOS
threshold.
34
©Tejas Networks Proprietary & Confidential
Alarms reported by OFA card
• Loss of input alarm:- When Rx power goes
below LOS threshold value.
• Los of out put power alarm :- When set gain
does not match with achieved gain.
• Pump Over current alarm:- When Pump
current overshot the maximum limit.
• Pump temperature alarm:- when pump
temperature value goes above maximum limit.
35
©Tejas Networks Proprietary & Confidential
OSC filter
• Optical supervisory channels are used for monitoring and
management of DWDM nodes.
• OSC channel lies out side C band(1510nm). Hence need to be
dropped before getting in to DWDM components(ROADM,
OFA etc.,)
• OSC filters are used to add/drop OSC channels.
• OSC filters are used with OFA card.
From
OFA Tx
To OFA DWDM+OSC
Rx From
To OSC OSC SFP
SFP
37
©Tejas Networks Proprietary & Confidential
OSC
TJ3500
filter network connectivity
TJ3500
TJ3310
OSCPort1Tx
OSCPort1 Rx OSCPort2 Tx
OSCPor2Rx
OSCPort1 Rx
C Tx
OSCPort1 Tx
38
©Tejas Networks Proprietary & Confidential
Reconfigurable Optical Add Drop
Multiplexer (ROADM) cards
ROADM-2-C-050G
ROADM-4-C-050G
ROADM-8-C-050G
39
©Tejas Networks Proprietary & Confidential
Inside ROADM Cards 1
1
1
2
2
2
3
3
3
4
4
4
A/D Tx A/D Rx
Splitter WSS
RAODM-4-C-50G 1 2 4
Common Tx
Common Rx
41
©Tejas Networks Proprietary & Confidential
Port connectivity for 2 degree
ROADM node
Degree Degree
RAODM RAODM
ROADM-4-C-50G
ROADM-4-C-50G
To
network
To
network
ROADM-8-C-50G
MDU-40 MDU-40
43
©Tejas Networks Proprietary & Confidential
Port connect and Lambda connect
• Port connect:- A port connect represent a
physical connection between the ports.
• All the physical connection(fiber connectivity)
made for a lambda path must be represented
as a port connect.
• Multiple Lambda path can be associated with a
single port connect.
•
44
©Tejas Networks Proprietary & Confidential
Making port connect
• Go to DWDM tab in node UI
• Go to Configuration Port connet select add
port connect option.
• Select source and destination card and ports
between which port connect has to be made.
• Make sure that fiber connectivity is made
between appropriate port as mentioned in the
port connect.
• Misconnection of port may lead to traffic failure.
45
©Tejas Networks Proprietary & Confidential
Making a Lambda connection
• Make sure that there is ports connect exist
corresponding to the Lambda path to be
made.
• Similar to making a cross connect.
• For making lambda connection Go to DWDM
tab Configuration Lambda connection.
• Chose the lambda(frequency), source and
destination ports between which a lambda
path has to be made.
46
©Tejas Networks Proprietary & Confidential
ROADM Site: Colourless and
Directionless
• 80 Channel
Directionless and
Colourless ROADM
LINE DIR. 1 LINE DIR. 2 design
• High insertion loss
LINE DIR. 3 LINE DIR. 4 needs to be taken care
-12dBm/ch by extra off-line
amplifiers
• Various types of
amplifiers (including
high power) needed to
-5dBm/ch be used in the line
directions
-23dBm/ch 1dBm/ch
• 1+1+R Design [1+1 in
electrical plane for
-15dBm/ch 50ms and Restoration
at ROADM ( ~ a few
sec)]
0dBm/ch
47
©Tejas Networks Proprietary & Confidential
ROADM node with fixed MDUs
ROADM8-C
DCM
OSCF - S
ROADM4-C
ROADM4-C
OSCF - S
ROADM-8C
ILU ILU
MDU-40-O MDU-40-E
1G
48
©Tejas Networks Proprietary & Confidential
Configuration of a 80 channel
colourless add/drop node.
ROADM8-C
DCM
ROADM4-C
ROADM4-C
OSCF - S
-12dBm/ch
OSCF - S
ROADM-8C
-5dBm/ch
A1 1dBm/ch
-23dBm/ch 2xPSCM1x5
MDU16-CL-C-50G
-15dBm/ch
AGG40 AGG40-SFP CEF-3
0dBm/ch
49
©Tejas Networks Proprietary & Confidential
Optical power monitoring(OPM)
card
• Monitor the power levels of individual channels.
• Used to isolated Link or channel issues in a the link.
• Typically they can be used in conjunction with any
optical Mon port such of OFA, MDU40 etc.
• They cover 192.00 THz to 195.95 THz
50
©Tejas Networks Proprietary & Confidential
• Draft Pictures of Optical Power Monitor card – needs to
be used with the HCPADP02 (1/2+1/2) adaptor cards
• OPM-2-C-50G has 2 input ports (Rx) and OPM-4-C-50G
has 4 input ports (Rx) for per channel power monitoring
at 50GHz
51
©Tejas Networks Proprietary & Confidential
OCM in a ROADM node
ROADM-4-C-50G
ROADM-4-C-50G
OCM-2-C-50G
OCM-2-C-50G
ROADM-8-C-50G
MDU-40
52
©Tejas Networks Proprietary & Confidential
Some Aspects of link Design
54
©Tejas Networks Proprietary & Confidential
Link Budgeting with a single Amplifier (Loss
Limited Transmission)
Without Amplifier:
Link Budget (dB)/Ch: Tx_Power (dBm) – Rx_Power (dBm) - Path Penalty (dB) – 2 x MDU/OADM Insertion (dB)
= 0 – 24 – 2 - 7
= 15 dB (~ 50-60 km)
Link Budget (dB)/Ch: Pout /Ch (dBm) –Rx_Power (dBm)- Path Penalty (dB) - 1 x MDU/OADM Insertion (dB)
= 8 – 24 – 2 - 3.5
= 26.5 dB (~ 100-120 km)
G, NF
56
Dispersion
• Dispersion simply means “to spread
out”(broadening of optical pulse).
• In optical networking, this results in signal
degradation.
57
©Tejas Networks Proprietary & Confidential
Signal Quality- Under Various
Condition
At the transmitter
59
©Tejas Networks Proprietary & Confidential
Tejas 10G Optical Interface Parameters
• OSNR Penalty ~ 2dB
• Rx power -8dBm to -
15dBm
• Residual Dispersion:
-30km to 60km
– OSNR up to 17dB with GFEC
– OSNR up to 14dB with EFEC
Gain Tilt
30
G= 28 dB
25 G= 23 dB
20 G= 18 dB
Gain indB
15 G= 13 dB
10
5
OFA 17dBm
0
1535.8 1540.8 1545.8 1550.8 1555.8 nm
• Fixed Gain Flattening Filter gives flat gain only for one gain
value.
• OFA 17 : Optimized gain 23 dB
• OFA 20 HG : Optimized gain 26 dB
• OFA20 LG: Optimized gain 22dB
• Rule of thumb: 10 dB changed gain =>
± 2.3 dB gain tilt at short/long wavelength
• Narrower window gives less gain tilt
Gain Tilt in cascaded amplifier
chain (Fixed Amplifier)
Psig Psig Psig Psig
l l l l
G G G
G<Gopt G=Gopt G>Gopt
l l l
Amplifier input and Gain seting
OSNR dB 58 Pout ( dBm ) L NF dB 10 log N amp
20 = -6 + 26
Pout (dBm) - 10*Log (N) = Pin (dBm) -10 Log (N) + G (dB) -25dBm/ch 1 dBm/ch
20 – 10* Log (80) = -6 - 10*Log (80) + 26
20 – 19 = -6 – 19 + 26
1 = -25 + 26
Dispersion
ATT Compensator