Thermal Power Plant
Conversion of MW to MU
⦿ Levelised Tariff – Tariff for entire life of the plant and in a single
part tariff with no components. It is weighted mean which
weighted w. r. to Discounting Factor ( Based on Discounting
Rate).
PRINCIPLE & COMPONENTS
Capital Cost
Debt Equity Ratio
PRINCIPLE & COMPONENTS
(Fixed Cost Components)
⦿ ROE
⦿ Interest on Loan
⦿ Working Capital
Depreciation Rate
Primary fuel
Secondary Fuel
OTHER TERMS
1000000
= 7446 MU ----------------------------------A
Fixed Cost Calculation
ROE
15.5% of Equity Component
15.5% of 1200 Crore= 186 Cr. ----------------------1.
Interest on Loan
10% of Loan Component
10% of 2800 Crore= 280 Cr. ------------------------2.
Continue…
2425 = x + 20
X = 2405 Kcal/Kwh (Heat Contribution Required from Coal)
Calorific Value of Coal = 4000 Kcal/Kg
⦿ So
Coal Required for 1 Kwh Generation = 0.60125 Kg
-------11.
Please Note
Auxiliary Consumption = 7.5%
This power is not available for sale and the cost of the generation of this
power has to be loaded on the power which is sold in market so…….
= Equation 7 + Equation 12
= 1.186+ 0.67125