Sie sind auf Seite 1von 11

K3VL Series

Swash Plate Type Axial Piston Pump used


for ‘Open Circuit’ Applications.
K3VL Series
Torque Limiting

Developed based on K3V/K5V series


・High Reliability and Long Life
・Reliable K3V/K5V rotating parts
・High Efficiency and High Inlet Capability.

Low Noise and High Stability


・Optimized valve plate design for noise
and pump control stability

Integrated Control Package


・Load Sensing, Pressure Cut-Off, Torque Limiting Load Sensing / Pressure Cut-Off
・Unloading valve, Variable pressure control with
solenoid valve available

SAE/ISO standard mounting and porting


SAE Through Drive Options
K3VL Series: Specifications

TYPE K3VL45 K3VL60 K3VL80 K3VL112 K3VL140 K3VL200


DISPLACEMENT (cm3/rev) 45 60 80 112 140 200
PRESSURE RATED 32 25 32
(MPa) PEAK 35 28 35
MAX.
2,700 2,400 2,400 2,200 2,200 1,900
SPEED (min-1) Self-Priming
MAX. 3,250 3,000 3,000 2,700 2,500 2,200
MAX. INPUT TORQUE (N m) 225 225 400 699 699 1,000
K3VL Series Structure Self Compensating Return Mechanism
High resistance against contamination

Through Drive Options for


Rigid Swash plate support Auxiliary Pumps SAE A to SAE D

Low Noise Valve Plate


Rigid Compact Casing High Speed/High Suction Capability/High
Efficiency/Stable Cylinder Position
Low Noise Technology

(1) Optimize the direction and the Yoke


variance of the yoke moment. Moment

(2) Smooth the accelerated pressure and


the decelerated pressure of the delivery.
(3) Minimize the variance of delivery flow.
95
90
85
80
P.W.L. [dB(A)]

75
70
3 dB reduction compared
65 to conventional model
60
55 K3V L140_std O .A 91.9dB (A )
50 Better Noise Quality by
K3V L140_im p O .A 88.9dB (A )
45
40
Reducing Noise level at
35 high frequency range
80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 O .A .
1/3 octave band frequency [H z]
Improved Shoe Material
• More Reliable with New Shoe K3VG112 Pump
Material Continuous High Load
Improve corrosion resistance by adjusting Endurance Test
chemical composition of the shoe material 1800min-1,
Significant Improvement of life under special 1/3αmax, 50℃
fluid

Mineral Oil 52.2MPa Polyol Ester Fluid 47.5MPa


1600
Ave. 1371h 800
1400 800
連続耐久寿命[hr]

Running hours(hr)
2 times 600 Ave. 590hrs
Running hours(hr)

1200 600
No Failure

400

200

1000 0

Ave. 711h D合金 E合金


4 times
800 高圧耐久 (40MPa, 400
600 特殊作動油)
200 Ave. 143hrs
400
200
0
0
Conventional New Conventional New
Material Material
K3VL Regulator Option [Basic]
K3VL Regulator Option [Special]
Mounting Variations
[Shaft and Mounting Flange]
Generator
Hyd. unit of press machine Fire truck
6000 5522
KPM-UK
KPMA
Total Sales Volume (unit)

5000
KPMJ
4000 3374

2587
3000
1698
2000
1200
1000 379
63

Marine unit 0
1999 2000 2001 2002 2003 2004 2005
Tele handler
Fiscal Year

Detachable body truck


Dump truck Forester machine
K3VL Success
• Dump Truck
Steering and Break, Lift

• Marine Winch

• Forestry Machines

• Small Press Machine